WEINTEK KEYENCE KV-8000-KV-X Symbolic Ethernet Programmable Logic Controller
Nkọwapụta
- Usoro akwadoro: KEYENCE KV-8000, KEYENCE KV-X310
- Websaịtị: http://www.keyence.com/
Ntuziaka nwụnye
Ntọala HMI:
| Oke | Akwadoro | Nhọrọ | Ihe ndetu |
| Ụdị PLC | KEYENCE KV-8000/KV-X (Symbolic) (Ethernet) | ||
| PLC I/F | Ethernet | ||
| Port No. | 8500 | ||
| Ụdị ngwaọrụ | KV8000 | KV8000 / KVX | |
| Simulator n'ịntanetị | Ee | Multi-HMI jikọọ | Ee |
Mbupụ Tags:
Software KV STUDIO creates tag:
- Variable -> Cerected tag on Global or Local table.

- Support Sturcutre address.

- Mbupụ tag: File -> Output CSV/TXT file -> Variable information

Bubata Tags:
- In EasyBuilder Pro -> System Parameter Settings -> New Driver (KV-8000) -> Import Tags.

- Select the .txt file mbubata.

- Import some or all of the tags

- Họrọ nke tag you want to import in Tag Manager, press OK.

- Ebubatara tag ozi ọma.

Ụdị Ngwaọrụ Nkwado
| Ụdị data | Ụdị data EasyBuilder | Memo |
| BOOL | bit | |
| INT | 16-bit BCD, Hex, ọnụọgụ abụọ, bịanyere aka na ya | 16-bit |
| UNINT | 16-bit BCD, Hex, ọnụọgụ abụọ, enweghị aha | 16-bit |
| DINT | 32-bit BCD, Hex, ọnụọgụ abụọ, bịanyere aka na ya | 32-bit |
| UDINT | 32-bit BCD, Hex, ọnụọgụ abụọ, enweghị aha | 32-bit |
| EZIOKWU | 32-bit Float | 32-bit |
| EZIOKWU | 64-bit Float | 64-bit * Ihe ịrịba ama1 |
| Ụdọ | Nhazi okwu maka ntinye na ngosi ASCII | * Ihe ịrịba ama2 |
|
N'usoro |
BOOL, INT, UINT, DINT,UDINT, REAL,
LREAL, Structure * Ihe ịrịba ama3 |
|
|
Nhazi |
BOOL, INT, UINT, DINT,UDINT, REAL, LREAL, STRING
N'usoro |
- Rịba ama1: EBPro V6.03.02 ma ọ bụ emesia na-akwado ụdị data 64-bit (naanị cMT Series), mana biko mara na oke njedebe adreesị bụ 48 bits na kacha.
- Rịba ama 2: String In EasyBuilder Pro, only even addresses can be selected, and support string length up to 2000.

- Rịba ama 3: Support 1~3D array, 4D arrays and above cannot be imported.
Eserese waya
eriri Ethernet:

Ajụjụ
How do I connect multiple HMIs?
You can connect multiple HMIs using the on-line simulator option in the HMI settings.
What is the maximum string length supported for STRING data type?
In EasyBuilder Pro, only even addresses can be selected, and it supports string length up to 2000.
Akwụkwọ / akụrụngwa
![]() |
WEINTEK KEYENCE KV-8000-KV-X Symbolic Ethernet Programmable Logic Controller [pdf] Ntuziaka onye ọrụ KEYENCE KV-8000-KV-X, KEYENCE KV-8000-KV-X Symbolic Ethernet Programmable Logic Controller, Symbolic Ethernet Programmable Logic Controller, Ethernet Programmable Logic Controller, Programmable Logic Controller, Logic Controller |