WG2A Smart Logic Controller na-enweghị mmiri

Ozi ngwaahịa
Nkọwapụta
- Model: Smart Logic Controller
- Ọrụ: Ọrụ PLC & Usoro
- Onye nrụpụta: mkpokọta Green Mfg.
- Njikwa: PLC na-achịkwa
- Stage: 2-stage na multi-arụ ọrụ nkeji
- Ndakọrịta: Na-arụ ọrụ na okpomọkụ / oyi dị iche iche
Nkwuputa
Nrụnye na ịrụ ọrụ nke ọma nke Mgbapụta Okpomọkụ Green Mfg dị mkpa maka ịrụ ọrụ a pụrụ ịdabere na ya. Sistemu Total Green Mfg ga-enwerịrị ike itinye ma rụọ ọrụ site n'aka onye ọrụ nkwekọrịta HVAC tozuru oke. Nhazi akụrụngwa, nhọrọ na nrụnye bụ naanị ọrụ dịịrị onye ọrụ nrụnye.
Achọghị ịwụnye akụrụngwa n'ụdị loop ọla kọpa dị adị nke na-adabaghị na mkpokọta Green Mfg earth loop dị ugbu a, ga-emebi ikike niile dị na akụrụngwa ahụ, yana naanị ọrụ dịịrị onye nrụnye. A ghaghị ime ntinye n'ime ntụziaka ndị e depụtara n'akwụkwọ ntuziaka a. Ọdịda ịnye nrụnye site n'aka onye ọrụ nkwekọrịta HVAC tozuru etozu n'ụzọ kwekọrọ na akwụkwọ ntuziaka a ga-emebi ma mebie oke mkpuchi ikike maka sistemụ a.
Mkpokọta Green Mfg agaghị akwụ ụgwọ maka ntụpọ ọ bụla, arụmọrụ na-adịghị mma, mmebi ma ọ bụ mfu, ma ọ bụ kpọmkwem ma ọ bụ dị mkpa, metụtara imewe, nrụpụta, iwu, ngwa ma ọ bụ ntinye nke mpaghara ọ bụla akọwapụtara.
mkpokọta Green Mfg. 2 stage na nkeji ọrụ dị iche iche ga-enwe ibe njedebe dị iche iche akpọrọ "thermostat/ zone board" na "onye na-ahụ maka ikuku / ọkụ" maka obere vol.tage na ndị PLC “na-achịkwa.
Maka ịrụ ọrụ akụrụngwa kwesịrị ekwesị, a ga-ejikọrịrị thermostat ma ọ bụ bọọdụ mpaghara na eriri “thermostat/ zone board terminal”. A ga-ekekọta onye na-ahụ maka ikuku ma ọ bụ ọkụ n'ọnụ ọnụ ọnụ “onye na-ahụ maka ikuku/ọkụ”. A ga-enwekwa ibe ọnụ ọnụ maka ọrụ dị iche iche dabere na ụdị ụdị ị na-arụ ọrụ. Ozi enyere ebe a bụ ịgbakwunye akwụkwọ ntuziaka nrụnye kpọmkwem maka nkeji gị.
Mkpa: For WG2A, WG1AH, WG2AH and WG2AD unit’s, if using a cased coil over a furnace, do NOT program your thermostat for dual fuel mode or, use the furnace settings. Leave the thermostat set to electric aux. heat, otherwise, you may interfere with proper PLC function. Follow the dual fuel function option for the unit model you are installing. This information is detailed in your unit installation manual. You will also want to check the aux. heat cycle rate (CPH) setting in the thermostat and set this to 1 or, the lowest available value depending on your thermostat brand and model.
Smart Logic Controller
WG2A Forced Air Only– List of functions
- The PLC checks that the LOW/HIGH pressure and discharge temperature switches are made. An open pressure switch input has a 60 second delay before setting a lockout and fault signal to
“X”. During this 60 second time period, the compressor will only operate in 1st stage naanị inye usoro ahụ ohere iji nwetaghachi tupu ịtọba mkpọchi siri ike. Nke a bụ iji gbochie oku mkpasu iwe, karịsịa na mmalite nke oge oyi mgbe Uwa Loops nọ na oyi ha kacha. “X” ka edobere ya na ọnọdụ mkpọchi siri ike ọ bụla. Na-atụgharị obere voltage na compressor unit gbanyụọ wee laghachi na resets lockout ọ bụrụhaala na ihapu okpomọkụ mgba ọkụ adịghị emeghe. Mgbanwe okpomọkụ nke mgbapụta nwere bọtịnụ nrụpụta akwụkwọ ntuziaka. Mgbanwe okpomọkụ na-emepe emepe ga-achọ nrụpụta akwụkwọ ntuziaka yana volta dị alatage ike okirikiri. Mgbanwe nrụgide na-akpaghị aka. - A “Y1” call starts 1st stage kpo oku ma ọ bụ jụrụ oyi nke ga-aga n'ihu maka nkeji 20 wee oge ruo nkeji abụọtagỌ bụrụ na oge ahụ gafere na-enweghị temomestat na-akpọ "Y2". Ọ bụrụ na unit ahụ nọ na ọnọdụ kpo oku, otu ugboro 2nd stage na-amalite, ihe ngụ oge 20 nkeji ga-eweta okpomọkụ AUX ma oge ahụ gafere na-enweghị afọ ojuju oku oku. Ozugbo niile stagAkpọọla ha, a ga-akpọ ha ruo mgbe igwe ọkụ na-eju afọ.
- If more than 3 consecutive “Y1” calls take place without the thermostat calling for 2nd stage n'ime nkeji iri abụọ ma ọ bụ, tupu nkeji 20 nke abụọ stage ngụ oge gwụchara, na oku “Y1” nke anọ, a na-amalite usoro nrụzi nke ga-ejide ma kpochie sistemu ahụ n'ime nkeji abụọ.tage maka nkeji 5 iji mesie mmanụ ike laghachi na compressor. Ọ bụrụ na etinyere sistemu ikuku, ebe mpaghara Override “D” ga-enye ike ruo 24 volts. Dịka akọwara n'akwụkwọ ntuziaka nrụnye nke otu gị, enwere ike iji mgbama 24-volt a yana mpaghara ọpụrụiche ewepụtara iji kpọọ mepee mpaghara kacha ukwuu wee jide d.ampEmeghe ka onye na-afụ ọkụ ahụ ghara ịhụ nrụgide kwụ ọtọ n'ime nkeji ise ahụ. Usoro mmezi ahụ na-akpọchi oku ọzọ ruo mgbe emechara. Mgbe usoro nrụzi gachara, ma ọ bụ ọ bụrụ na akpọọ “Y5” tupu usoro mmezi emee, counter resets back to efu. Nke a na-eme ka mpaghara sistemụ anyị nwee enyi dịka ọ na-enye ohere maka 2 s n'ezietages kpo oku na obi jụrụ.
- There is an installed jumper on the field wiring terminal block marked “A” and “S”. With the jumper installed, the unit will function with an aux heat strip as normal. If the jumper is removed, the PLC goes into dual fuel mode stopping the compressor when there is a call for aux heat. Once the aux heat call completes, a 5-minute cool down timer prevents the compressor from restarting on a “Y” call until the time elapses. This allows time for the furnace to cool so hot air doesn’t cause high discharge pressure or a lockout when the compressor restarts.
- When the thermostat is set to cooling mode, the “O” signal energizes the reversing valve and locks out the aux heat output.
- In an effort the reduce energy consumption, the PLC turns power off to the crank case heater when the compressor runs.
- This PLC program also allows the use of almost any heat/cool thermostat. Even if a single stage okpomọkụ/oyi naanị thermostat na-eji, ihe omume PLC ga-ejikwa niile ọrụ stagnke abụọ stage na AUX Okpomọkụ dị ka achọrọ.
WGxAH Single na Abụọ Stage Amanye Ikuku na Hydronic Heating Ọrụ
In addition to the function and features as described for WG2A units, The PLC program for the WGxAH units allows for switching priority call from forced air to hydronic heating as well as a feature
called “Split Zone” that are installer optioned by choosing jumper settings as described below.
- A jumper is used on the field wiring terminal strip between the “R” and “AW” terminals to prioritize air heating over hydronic heating. When this jumper is removed, hydronic heating becomes the priority call.
- Split Zone is a feature which allows you the ability to heat one zone or floor with hydronic heat and another zone or floor with forced air. Split Zone is active by removing the priority call jumper across “R” and “AW” moving it across the “R” and “SZ” of the field wiring terminal block.
- While in “Split Zone” mode, the compressor unit will provided forced air heating to the air zone. When the buffer storage tank calls for heat, the compressor unit will shift to heat water. Should a call for the air zone take place while the compressor unit is heating water, the call goes directly to the aux heat source to maintain the air zone. Once the tank temperature is satisfied, the system diverts back to normal air heating with the compressor unit.
- When a hydronic heat call from the buffer tank takes place, the compressor turns off if it is running. 1 minute after that, the circulator pump starts to establish good water flow, the 3 way valve energizes and the SV1 valve de-energizes. 1 minute after that the compressor starts. Once the tank thermostat is satisfied, the compressor stops and the pump will continue to run for 30 seconds before turning off to gain any residual heat from the heat exchanger. 1 minute after the compressor stops, the 3-way valve de-energizes. 1 minute after that the compressor can restart for an air zone call. These timed cycles reduce system component wear by not having to shift under pressure or load.
- The Hydronic heating function is disabled anytime the “O’ terminal is energized placing the unit in cooling mode.
WG2AD Amanye Ikuku na arụ ọrụ kpo oku mmiri
Na mgbakwunye na ọrụ na njirimara dịka akọwara maka nkeji WG2A dị ka akọwara na ngalaba mbụ nke akwụkwọ a, mmemme PLC maka nkeji WG2AD na-enye ohere ịgbanwe oku kacha mkpa site na ikuku mmanye gaa na kpo oku ụlọ.
- A jumper is used on the field wiring terminal strip between the “R” and “AW” terminals to prioritize air heating/cooling over domestic water heating. When this jumper is removed, domestic water heating becomes the priority call.
- When a water heating call from the water tank takes place, the compressor turns off if it is running. 1 minute after that, the circulator pump starts to establish good water flow, the 3 way valve energizes and the SV1 valve de-energizes. 1 minute after that the compressor starts. Once the tank thermostat is satisfied, the compressor stops and the pump will continue to run for 30 seconds before turning off to gain any residual heat from the heat exchanger. 1 minute after the compressor stops, the 3-way valve de-energizes. 1 minute after that the compressor can restart for an air zone call. These timed cycles reduce system component wear by not having to shift under pressure or load.
- An added functional PLC feature exclusive to the WG2AD model which allows water heating up 120 degrees, is the unit’s ability to maintain compressor stability by throttling the compressor load as needed to control discharge pressure.
WG1H 100% Hydronic Heated and Chilled Water Only– List of functions
- The PLC checks that the LOW/HIGH pressure, HX Low and Discharge temperature switches are made. An open safety switch input has a 60 second delay before setting a lockout and fault signal to “X”. This is to prevent nuisance calls, especially at the beginning of the cooling season when the Earth Loops are at their coldest. “X” is set with any hard lockout condition. Turning the low voltage na compressor unit gbanyụọ wee laghachi na resets lockout ọ bụrụhaala na ihapu okpomọkụ mgba ọkụ adịghị emeghe. Mgbanwe okpomọkụ nke mgbapụta nwere bọtịnụ nrụpụta akwụkwọ ntuziaka. Mgbanwe okpomọkụ na-emepe emepe ga-achọ nrụpụta akwụkwọ ntuziaka yana volta dị alatage ike okirikiri. Nrụgide na HX Igwe ọkụ ọkụ dị ala bụ akpaka.
- An “N” call starts the circulator pump for 30 seconds prior to the compressor to allow for full flow through the HX (heat exchanger) prior to starting the compressor. Once the call is complete, the pump will run an addition 30 seconds after the compressor stops to purge the HX of any residual heat. This occurs regardless of either a heated or chilled water call.
If you have any questions regarding any of these functions, please contact Total Green Mfg. at 419-678-2032 maka nkwado teknụzụ.
Ajụjụ a na-ajụkarị
- Ajụjụ: Kedu ka m ga-esi ebute ikpo ọkụ ikuku ụzọ karịa ikpo ọkụ hydronic na nkeji WGxAH?
A: Remove the jumper between R and AW terminals on the field wiring terminal strip. - Ajụjụ: Kedu ka atụmatụ mpaghara Split si arụ ọrụ na nkeji WGxAH?
A: Move the jumper from R and AW terminals to R and SZ on the field wiring terminal block to activate Split Zone.
Akwụkwọ / akụrụngwa
![]() |
WG2A Smart Logic Controller na-enweghị mmiri [pdf] Akwụkwọ ntuziaka WG2A, WG1AH, WG2AH, WG2AD, WG2A Smart Logic Controller, WG2A, Smart Logic Controller, Logic Controller, Controller |