tait-logo

Tait TD9300 DMR Data Terminal

tait-TD9300-DMR-Data-Terminal-product

Ozi ngwaahịa

  • Nchekwa nkeonwe
    • Gburugburu ebe mgbawa: Ejila akụrụngwa rụọ ọrụ n'akụkụ mkpuchi ọkụ eletrik ma ọ bụ n'ikuku mgbawa.
    • Proximity to RF transmissions: Maintain a safe separation distance of at least 5.3 feet (1.6 meters) from the antenna system to comply with RF Field Limits for Devices Used by the General Public.
  • Ọnọdụ gburugburu
    • Oke okpomoku na-arụ ọrụ: Ensure the equipment operates within specified temperature ranges.
    • iru mmiri: Iru mmiri ekwesịghị gafere 95% iru iru mmiri site na oke okpomọkụ na-arụ ọrụ.
    • Uzuzu na unyi: Ingress protection ratings: IP40, IP41 with front panel connectors facing down.
  • Nchekwa ala na ọkụ
    • Ntọala eletrik: Utilize the provided grounding connector for connection to the site ground point.
    • Lightning Ground: Take adequate precautions against lightning strikes to protect the site and equipment.
  • Ngwa ikuku ikuku
    • Ensure there is adequate ventilation around the equipment to prevent overheating.
  • LED Safety (EN 60825-1)
    • Ngwa a nwere Ngwaahịa ikanam klaasị 1.
  • Isolation (EN 60255-5)
    • Models with isolated ports are tested to specific levels for DC and Signal ports isolation.
  • Akpachara anya ESD
    • It is recommended to purchase an antistatic bench kit and follow installation instructions to prevent electrostatic discharge (ESD).

Ntuziaka ojiji ngwaahịa

Usoro nchekwa

  • Avoid operating in explosive environments or near electrical blasting caps.
  • Maintain a safe distance of at least 5.3 feet from the antenna system to comply with RF Field Limits.
  • Avoid touching the RF antenna while it is connected to prevent RF burns.
  • Avoid touching the hot surfaces of the terminal during prolonged operation.

Ọnọdụ gburugburu

  • Ensure the equipment operates within specified temperature ranges and humidity levels.
  • Protect the equipment from dust and dirt, following IP40 and IP41 ratings.

Nchekwa ala na ọkụ

  • Properly ground the equipment using the provided connector.
  • Take precautions against lightning strikes to ensure site and equipment security.

Ngwa ikuku ikuku

  • Maintain adequate ventilation around the equipment to prevent overheating.

Akpachara anya ESD

  • Purchase an antistatic bench kit and follow installation instructions to prevent electrostatic discharge.

Designed for telemetry and data communications, Tait DMR offers a secure and reliable M2M data terminal based on the DMR Tier 3 trunking standard.
The TD9300 terminal has multiple data interfaces and the intelligence to simplify wide area DMR-based connectivity, integrate quickly, and transparently support data communications.

ELU

tait-TD9300-DMR-Data-Terminal-fig-(1)

The TD9300, in conjunction with a SCADA Gateway and DMR tier III network, offers advanced data communications services for wireless networks.

  • Designed for M2M SCADA communications
  • Engineered for use in demanding environments
  • Full adherence to DMR standards, providing choice and interoperability
  • Native (SCADA protocol-aware) or Transparent IP data services
  • Flexible interfacing. Wide input voltage range, adjustable high power RF output, serial and Ethernet interfaces

Njiri mara na uru

  • Melite arụmọrụ
    • Monitor and control devices via long-range DMR, reduce travel & site visits
    • Centralized, standards-based network management
    • Design, manage, and maintain a single voice & data radio network
    • Designed to perform in demanding environments
    • Tough die-cast metal chassis protects in demanding environmental conditions
    • Protection and fold-back mechanisms limit hardware failures, automatically restore service after the fault is cleared.
    • Flexible mounting systems, DIN rail in both vertical and horizontal, on a 19-inch rack tray or wall-mounted
  • Nchekwa
    • AES-256-bit data encryption
    • Key management via web nhazi ibe
    • Terminals must both register and be authenticated to access the network
    • Stun and revive to disable devices
  • Remote site monitoring
    • Extensive outstation diagnostics:
    • Okpomọkụ
    • Signal (RSSI & BER, and MER)
    • Antenna fault
    • Ntinye voltage
    • Telemetry equipment status
    • Digital I/O
    • Over-the-air (OTA) configuration of
  • SCADA interface parameters, Standards-based interface protocols
    • Industry standard protocols:
    • DNP3 over IP/serial
    • IEC60870-5-101 and -104
    • MODBUS
    • Usoro oge netwọkụ (NTP)
    • Usoro ozi njikwa ịntanetị (ICMP)
    • Eliminates costly proprietary protocol integration and support
  • Ngwa
    • SCADA for distribution utilities
    • SCADA for oil & gas utilities
    • SCADA for control of irrigators
  • Ọrụ data
    • Packet data over traffic channels for telemetry, SCADA, and customer-specific applications
    • Native and Transparent IP data interface operation
    • Control channel short data messages, location, statu,s and text
  • Flexible interfaces
    • Two RS232 / RS485 serial interfaces for legacy equipment connection
    • 10/100 Mbps Ethernet connection
    • 2 digital inputs and 2 digital outputs to monitor and control the surrounding environment, fully isolated.

Backed up by our proven radio network expertise, the TD9300 is part of the Tait DMR solution portfolio that consists of terminals, infrastructure, applications, services, and integration with third-party interfaces to ensure that your organization can reap all the benefits of the spectrally-efficient DMR standard in a mission-critical environment.

Nkọwapụta

Izugbe

  • Ntinye voltage
  • Power consumption (@ 24VDC)
    • Tx current (peak)
    • Tx power consumption (average, single slot)
    • Standby (average) 9-36VDC
    • 3.1A for 25W RF power, 1.0A / 1.6A for 1W / 5W RF power
    • 40W for 25W RF power, 15W / 22W for 1W / 5W RF power 5.3W
  • Dimensions 180mm (w) x 156mm (~D) x 61mm (H)
  • Okpomọkụ na-arụ ọrụ -22°F ruo 140°F (-30°C ruo 60°C)
  • Water and dust protection IP40 in all orientations or IP41 with connectors facing down
  • Frequency stability ±0.5ppm (-22°F to 140°F/-30°C to 60°C)
  • Channel spacing 12.5kHz spacing 2.5 / 3.125 / 5 / 6.25kHz increment per channel step
  • Weight lb (kg) 4.2 lb (1.9kg)
  • Mounting the DIN rail clip or panel mount bracket
  • ESD rating +/-4kV contact discharge and +/-8kV air discharge
  • Air interface standard DMR: ETSI TS 102 361
  • Indicators 5 status LEDs: PWR, RTU, DMR, 1, 2
  • Packet Data ½ Rate, ¾ Rate, Full rate
  • General Purpose digital I/O Input: Opto-isolated, 18VDC max Output: Isolated, 170mA@18VDC

ebugharị

  • VHF 136-174MHz UHF 400-470MHz
  • Output power (configurable) 25W: 25W, 12.5W, 5W, 1W 25W: 25W, 12W, 5W, 1W
  • FM Hum and noise (TIA-603-D) 12.5kHz: 40dB 12.5kHz: 40dB
  • Adjacent channel power ratio (DMR, ETS 300-113) 12.5kHz: 60dBc 12.5kHz: 60dBc
  • Conducted Emissions 25W: -36dBm 25W: -36dBm
  • Usoro ọrụ:
    • 5W: 80% @ 25ºC 25% @ 60ºC
    • 12W: 75% @ 25ºC 20% @ 60ºC
    • 25W: 65% @ 25ºC 15% @ 60ºC

Nnata

  • VHF:  136-174MHz UHF , 400-470MHz
  • Mmetụta: (DMR) 5% BER -119dBm (0.25µV) -120dBm (0.25µV)
  • Intermodulation rejection: (EIA603D) 81dB 76dB
  • Intermodulation rejection: (ETS 300) 72dB 66dB
  • Spurious response rejection: (DMR) (ETS 300-113) 72dB 76dB
  • FM hum and noise: (TIA-603-D) 12.5kHz: 45dB 12.5kHz: 45dB
  • Emere ihe na-adịghị mma: -57dBm -57dBm
  • Nhọrọ ọwa n'akụkụ: (TIA/EIA one tone) 65dB 64dB
  • Nhọrọ ọwa n'akụkụ: (DMR, EN 300 113) 62dB 61dB

data iwu

tait-TD9300-DMR-Data-Terminal-fig-(2)

OTHER STANDARDS

  • Environmental Low Pressure (Altitude): MIL-STD-810G 500.5, Proc 2
  • Okpomọkụ dị elu: MIL-STD-810G 501.5, Proc 1,2
  • Okpomọkụ dị ala: MIL-STD-810G 502.5, Proc 1,2
  • Okpomọkụ Shock: MIL-STD-810G 503.5, Proc 1
  • iru mmiri: MIL-STD-810G 507.5, Proc 2
  • Mmaji: MIL-STD-810G 514.6, Proc 1
  • Ujo: MIL-STD-810G 516.6, Proc 1

Specifications are subject to change without notice and shall not form part of any contract. They are issued for guidance purposes only.

  • All specifications shown are typical.
  • For further information, please check with your nearest Tait office or authorized dealer.

TD9300_SS_v15.0_A4

  • Tait Limited facilities are certified for ISO 9001:2015 (Quality Management System), ISO 14001:2015 (EnvironmentalManagement System), and BS OHSAS 18001:2007(Occupational Health and Safety Management System) for aspects associated with the design, manufacture, and distribution of radio communications and control equipment, systems and services.
  • In addition, all our Regional Head Offices are certified to ISO 9001.
  • The word “Tait” and the Tait logo are trademarks of Tait Limited.

tait-TD9300-DMR-Data-Terminal-fig-(3)

Ozi ndị ọzọ

Ajụjụ a na-ajụkarị

Q: What should I do if I need more information on antistatic precautions?

A: You can obtain further information on antistatic precautions and dangers of electrostatic discharge (ESD) from standards such as ANSI/ESD S20.201999 or BS EN 100015-4 1994.

Q: How do I ensure proper grounding of the equipment?

A: Utilize the provided grounding connector on the front panel for connection to the site ground point.

Akwụkwọ / akụrụngwa

tait TD9300 DMR Data Terminal [pdf] Akwụkwọ ntuziaka
MNE-00021, MNE-00021-07, TD9300 DMR Data Terminal, TD9300, DMR Data Terminal, Data Terminal, Terminal

Ntụaka

Hapụ ikwu