SYSTEM SENSOR CR-6A Six Relay Control Module

Nkọwapụta
- Nrụ ọrụ nkịtị Voltage: 15-29 VDC
- Njikere ugbu a: 1.9 mA
- Oti mkpu ugbu a: 32 mA (assumes all six relays have been switched once and all six LEDs solid on)
- Oke okpomọkụ: 32°F ruo 120°F (0°C ruo 49°C)
- iru mmiri: 10 to 93% Noncondensing;
- Akụkụ: 6.8″H x 5.8″W x 1.0″D (173mm H x 147mm W x 25mm D)
- Ngwa: BB-2A Cabinet; BB-6A Cabinet; CH-6A Chassis or suitably grounded metallic cabinet
- Waya nlele: 12-18 AWG (0.9mm2 – 3.25mm2 )
- Relay Current: 30 mA/Relay Pulse (15.6 mS pulse duration) pulse under panel control
- Ọnụ ala Voltage (Isolation) Min. 4 VDC
- Ibu Enyere Oke: 0.5A
- Kachasị mgbanwe ugbu a: 0.5A
| ỌRỤ dị ugbu a | Oke VOLTAGE | Nkọwapụta ibu | Ngwa |
| 2A | 25VAC | PF = 0.35 | Non Coded |
| 3A | 30VDC | Nguzogide | Non Coded |
| 2A | 30VDC | Nguzogide | Edebere koodu |
| 0.46A | 30VDC | (L/R = 20ms) | Non Coded |
| 0.7A | 70.7VAC | PF = 0.35 | Non Coded |
| 0.9A | 125VDC | Nguzogide | Non Coded |
| 0.5A | 125VAC | PF = 0.75 | Non Coded |
| 0.3A | 125VAC | PF = 0.35 | Non Coded |
IHE: Ekwesịrị ịhapụ akwụkwọ ntuziaka a n'aka onye nwe / onye ọrụ a.
Tupu ịwụnye
This information is included as a quick reference installation guide. If the modules will be installed in an existing operational system, inform the operator and local authority that the system will be temporarily out of service. Disconnect the power to the control panel before installing the modules. This system contains static sensitive components. Always ground yourself with a proper wrist strap before handling any circuits so that static charges are removed from the body. The housing cabinet should be metallic and suitably grounded.
Nkowa Izugbe
The CR-6A Six Relay Control Module is intended for use in an intelligent alarm system. Each module is intended for Form-C switching applications, which do not require wiring super-vision for the load circuit. A single isolated set of dry relay contacts is provided for each module, which is capable of being wired for either normally open or normally closed for each operation. Each module has its own address. A pair of rotary code switches is used to set the address of the first module from 01 to 94 (or 01 to 154 for panels that support 159 addresses). The remaining modules are automatically assigned to the next five higher ad-dresses. Provisions are included for disabling a maximum of four unused modules to release the addresses to be used elsewhere. Each CR-6A module also has panel controlled green LED indicators. The panel can cause the LEDs to blink, latch on, or latch off.
gụnyere:
- (6) 1 × 3 Terminal Blocks
- (1) 1 × 4 Terminal Block
- (2) 1.25″ (32mm) Stand offs
- (4) Igwe kposara
- (2) Mkpụrụ
Achọrọ ndakọrịta
To ensure proper operation, this module shall be connected to a compatible control panel only.
Akụkụ
Following are descriptions of the CR-6A mounting frameworks. There are two mounting op-tions for CR-6A modules:
- Up to six CR-6A modules can be installed on a CH-6A in a BB-6A cabinet
- One or two CR-6A modules can be installed in a BB-2A cabinet
Chassis
The CH-6A chassis is used to mount CR-6A modules in a BB-6A cabinet. It accommodates up to six CR-6A modules in a single cabinet row three modules wide and two modules deep. (See Figure 1.)

The BB-2A cabinet has a built-in chassis that will accommodate one or two CR-6A modules. (See Figure 2.)

The front CR-6A module positions of each chassis are offset below the rear CR-6A module positions so that all of the status indicators are visible.
Ụlọ ụlọ
- A BB-6A cabinet will house the CH-6A chassis with up to six CR-6A modules installed on it.
- The BB-2A cabinet houses one or two CR-6A modules on the internal chassis that is part of the cabinet.
- Refer to cabinet installation documents for dimensions.
Nzọụkwụ ntinye
- Ịkwanye kabinet
In a clean, dry area, mount the backbox using the four holes provided in the back surface of the cabinet. (See Figure 3.) - Nwụnye chassis
The CH-6A chassis is mounted in the BB-6A cabinet. It is attached to the two PEM studs on the back wall of the cabinet with two 8-32 hex nuts. The hex nuts are included with the chassis. (See Figure 4.)

The BB-2A cabinet comes with the chassis already installed, so no mounting is necessary.
Ntinye Module
There are two methods for installing a module in the rear position of a chassis. Method one is for installation of a rear module only, when no module will be installed in front of it. Refer to Figure 5 for instructions. Method two is for installation of a rear module when another module will be installed in the chassis position in front of it. Refer to Figures 6a and 6b for method two. All necessary screws and standoffs are supplied with the modules.

- Step 1: Insert the bottom of the CR-6A module down into a rear slot on the chassis.
- Step 2: Carefully swing the upper edge of the board back towards the back of the chassis until it touches the two standoffs.
- Step 3: Align two 4-40 screws with the two standoffs and tighten.
- Step 4: Address and wire the modules according to the instructions in this manual.
The steps in Figures 6a and 6b describe and illustrate module installation when the rear chassis position and the position in front of it will be filled. Front position installation is possible only if the rear position is filled with a module.

- Step 1: Insert the bottom edge of the CR-6A module down into a rear slot of the chassis.
- Step 2: Carefully swing the bottom edge of the board towards the back of the board until it touches the short standoff attached to the chassis.
- Step 3: Align the long standoff with the short standoff and tighten.

- Step 1: Insert the bottom edge of the CR-6A module down into a front slot of the chassis.
- Step 2: Carefully swing the upper edge of the board towards the back of the chassis until it touches the 1.25″ (31.75mm) standoffs installed on the rear module.
- Step 3: Align two 4-40 screws with the two standoffs and tighten.
- Step 4: Address and wire the modules according to the instructions in this manual.
WIRING
IHE: Wiring niile ga-adabarịrị na koodu, iwu na ụkpụrụ mpaghara dị.
- Install module wiring in accordance with the job drawings and appropriate wiring dia-grams.
- Make electrical connections by stripping approximately ¼” (6.35mm) of insulation from the end of the wire sliding the bare end of the wire under the clamping plate, and tight-ening the clampefere efere ịghasa.
- Set the address on the modules per the job drawing. Use the rotary code switches to set the address of the first module between 01 and 94 (or 01 and 154 for panels that support 159 addresses). The remaining modules are automatically assigned to the next five higher addresses. For example, if the base address switch is set to 28, the next five modules will be addressed to 29, 30, 31, 32, and 33. DO NOT set the lowest address above 94 (or 154 for panels that support 159 addresses), as the other modules will be assigned to nonexistent addresses.

A dip switch is provided to disable a maximum of four unused modules. Modules are dis- abled from the highest address and work downward. If two modules are disabled, the lowest four addresses will be functional, while the highest two will be disabled. For example, if the dip switch for Address Disable is placed on “two” and the base address switch is set to 28, the modules will be assigned to 28, 29, 30 and 31.
IHE: Power must not be applied to the unit when changing functionality of the dip switches. NOTE: The CR-6A must have power cycled for dip switch changes to take effect.
IHE: All references to power limited represent “Power Limited (Class)
IHE:
- The relay contacts on the CR-6A may be connected to either a power-limited or non power-limited source, this wiring must remain separated by at least 0.25″ (6.35 mm) from all power-limited wiring.
- Sekit nwere oke ike ga-eji ụdị FPL, FPLR, ma ọ bụ FPLP eriri dịka nkeji 760 nke NEC chọrọ.
- Installation and wiring requirements shall be in accordance with CSA C22.1 and ULC S524.
- For easier wiring, assign all power-limited wiring to one side rather than alternating with non power-limited.
AMAOKWU OKWU AFỌ atọ
System Sensor warrants its enclosed module to be free from defects in materials and workmanship under normal use and service for a period of three years from date of manufacture. System Sensor makes no other express warranty for this smoke detector. No agent, representative, dealer, or employee of the Company has the authority to increase or alter the obligations or limitations of this Warranty. The Company’s obligation of this Warranty shall be limited to the repair or replacement of any part of the smoke detector which is found to be defective in materials or workmanship under normal use and service during the three year period commencing with the date of manufacture. After phoning System Sensor’s toll free number 1-800- SENSOR2 (736-7672) for a Return Authorization number, send defective units postage prepaid to: System Sensor Canada (3PL), c/o Kuehne and Nagel, 6335 Edwards Blvd., Mississauga, Ontario L5N 2W7, RA #__________. Please include a note describing the malfunction and suspected cause of failure. The Company shall not be obligated to repair or replace units which are found to be defective because of damage, unreasonable use, modifications, or alterations occurring after the date of manufacture. In no case shall the Company be liable for any consequential or incidental damages for breach of this or any other Warranty, expressed or implied whatsoever, even if the loss or damage is caused by the Company’s negligence or fault. Some legislations do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This Warranty gives you specific legal rights, and you may also have other rights under common law.
Nkwupụta FCC
Ngwaọrụ a na-akwado akụkụ 15 nke Iwu FCC. A na-arụ ọrụ n'okpuru ọnọdụ abụọ a:
- Ngwaọrụ a nwere ike ọ gaghị ebute nnyonye anya na-emerụ ahụ, yana
- Ngwaọrụ a ga-anabatarịrị nnyonye anya ọ bụla enwetara, gụnyere nnyonye anya nwere ike ibute ọrụ na-achọghị.
IHE: A nwalere ngwa a wee hụ na ọ dabara na oke maka ngwaọrụ dijitalụ klaasị B, dabere na akụkụ 15 nke Iwu FCC. Emebere oke ndị a iji nye nchebe ezi uche dị na ya megide nnyonye anya na-emerụ emerụ na ntinye ụlọ. Akụrụngwa a na-ewepụta, na-eji ma nwee ike ịgbasa ike ugboro redio yana, ọ bụrụ na etinyeghị ya ma jiri ya dịka ntuziaka siri dị, nwere ike ibute ndabichi na-emerụ ahụ na nkwukọrịta redio. Agbanyeghị, enweghị nkwa na nnyonye anya agaghị eme na otu nrụnye. Ọ bụrụ na akụrụngwa a na-ebute nnyonye anya na-emerụ ahụ na nnabata redio ma ọ bụ telivishọn, nke enwere ike ikpebi site na ịgbanyụ ma gbanye akụrụngwa, a na-agba onye ọrụ ume ka ọ nwaa idozi nnyonye anya site na otu ma ọ bụ karịa n'ime usoro ndị a:
- Megharịa ma ọ bụ bugharịa antenna nnata.
- Mee ka nkewa dị n'etiti akụrụngwa na nnata.
- Jikọọ akụrụngwa n'ime oghere na sekit dị iche na nke ejikọrọ onye nnata.
- Kpọtụrụ onye na-ere ahịa ma ọ bụ onye ọrụ redio/TV nwere ahụmahụ maka enyemaka.
Ngwaọrụ na nchekwa nchekwa
Tupu ịwụnye ngwaahịa a hụ na tamper akara na nkwakọ ngwaahịa dị ugbu a na-agbajighị ma ngwaahịa ahụ emebeghị tampered na kemgbe ọ hapụrụ factory. Awụnyela ngwaahịa a ma ọ bụrụ na enwere ihe ngosi ọ bụla nke tampeme ihe. Ọ bụrụ na e nwere ihe ịrịba ama nke tampekwesịrị iweghachite ngwaahịa a n'ebe azụrụ ya. Ọ bụ ọrụ onye nwe sistemu iji hụ na echekwara sistemu niile, ya bụ ngwaọrụ, ogwe, wiring wdg, nke ọma iji zere tampusoro nke nwere ike ibute nkpughe ozi, nhụsianya, na mmebi iwu.
FAQ
Can I install a module in the front position if the rear position is already filled?
Front position installation is possible only if the rear position is filled with a module.
Akwụkwọ / akụrụngwa
![]() |
SYSTEM SENSOR CR-6A Six Relay Control Module [pdf] Ntuziaka nwụnye I56-2186-002, CR-6A Six Relay Control Module, CR-6A, Six Relay Control Module, Relay Control Module, Control Module |