FSP PDU na Mgbanwe Mgbanwe Mgbanwe

FSP-PDU-and-Maintenance-Bypass-Switch-Module-PRODUCT.

Nkọwapụta

  • Ụdị: Bypass Switch Module V. 2.0
  • Ojiji: External power distribution unit for UPS systems or voltage regulators
  • Ịkwanye: Rack or Wall Mountable
  • Ike ntinye: Mains power cord
  • Mgbapụta mmepụta: Master for computer, Slave for peripherals
  • Ọrụ: Maintenance bypass, Power distribution, Power saving

Okwu mmalite

A na-eji ngwaahịa a dị ka ihe nkesa ike mpụga yana njikọ UPS ma ọ bụ nnukwu voltage regulators. It allows to manually transfer of the connected equipment to utility power via a bypass switch, permitting scheduled maintenance or UPS replacement without power interruption. Combined power distribution feature and the master-controlled design, it provides a maintenance bypass function and power saving within a rack mechanism.

Rack Mount/Wall Mount the Unit

The module can be mounted to a 19” enclosure or wall. Please follow chart below for rack/wall mount installation.FSP-PDU-and-Maintenance-Bypass-Switch-Module-FIG-1Ngwaahịa gafereview FSP-PDU-and-Maintenance-Bypass-Switch-Module-FIG-2

  1. Master output receptacle (for connecting a computer)
  2. Slave output receptacles (for connecting peripherals)
  3. Socket to UPS output
  4. Socket to UPS input
  5. Ngbanwe uzo
  6. Ntinye AC
  7. Ihe mgbaji sekit
  8. Master/Slave function switch
    • Ikanye ike
    • Ohu Na LED

Nwụnye na arụ ọrụ

Nyocha
Remove the unit from the shipping package and inspect it for damage that may have occurred during transportation. Notify the carrier and place of purchase if any damage is found. The shipping package contains:

  • Module mgba ọkụ mgbanaka na-emezi x 1
  • Ntuziaka ngwa ngwa x 1
  • Igwe ọkụ ọkụ x1
  • Kpọsara na ịrị elu ntị

Jikọọ na mpụga mgbidi
Plug the input power cord of the unit to the wall outlet. The Power LED will light up when the mains is normal. The Power LED will be off while power failure. FSP-PDU-and-Maintenance-Bypass-Switch-Module-FIG-3

Jikọọ UPS
Connect a power cord from UPS input to UPS input socket on the unit. Use one power cord to connect UPS output to UPS output socket on the unit. FSP-PDU-and-Maintenance-Bypass-Switch-Module-FIG-4

Jikọọ Ngwa
There are two types of output receptacles: Master and Slave. To save power consumption, the unit is equipped with Master and Slave output receptacles. The Master output receptacle will sense if the master device (computer) is on. If the master device is no longer drawing current, it will automatically shut down the power to the Slave output receptacles. Please refer to the charts below for detailed equipment connections.

FSP-PDU-and-Maintenance-Bypass-Switch-Module-FIG-5

IHE: When the computer is turned off, the Master output receptacle shuts off power to the slave output receptacles. However, when the computer goes into “sleep mode” or the power consumption of connected device to Master output receptacle is below 20 W, the Master output receptacle may not properly recognize the reduced power level.

Ọrụ

Nyefee na ngafe mmezi
Tupu ibufee na ngafe mmezi, gbaa mbọ hụ na ọkụ LED na-enwu. Nyefee ngbanwe ntụgharị ntụgharị site na "Nkịtị" gaa na "Nbanye". N'oge a, ngwaọrụ niile ejikọrọ na-akwado site na ike ịba uru ozugbo. Ị nwere ike gbanyụọ UPS wee kwụpụ eriri abụọ na-ejikọta na UPS. Mgbe ahụ ị nwere ike ịrụ ọrụ UPS ugbu a.

Nyefee na Nchedo UPS
After maintenance service is done, make sure the UPS operation is normal. Then, reconnect UPS to the unit by following Installation Section. Verify the Power LED is lighting. Then transfer the rotary bypass switch from “Bypass” to “Normal”. Now, all connected devices are protected by UPS.

Ọrụ Nna-ukwu/Ohu
Mgbe jikọọ ngwaọrụ niile na unit, pịa "Master / Slave switch" iji mee ka ọnọdụ (FSP-PDU-and-Maintenance-Bypass-Switch-Module-FIG-6 ). Ohu On LED ga-enwu mgbe ijikọ ibu na nrụpụta nna ukwu dị n'elu 20W. Pịa "Master/Ohu mgba ọkụ" iji gbanyụọ ọkwa (FSP-PDU-and-Maintenance-Bypass-Switch-Module-FIG-6), Akwụsịghị ọrụ ahụ yana Ohu On LED ga-agbanye.

Ọnọdụ & Tebụl ihe ngosi

FSP-PDU-and-Maintenance-Bypass-Switch-Module-FIG-7

Ịdọ aka ná ntị nchekwa dị mkpa (Chekwaa ntụziaka ndị a)

  • Iji rụọ ọrụ a n'enweghị nsogbu, biko gụọ ma soro ntuziaka niile nke ọma.
  • Gụọ akwụkwọ ntuziaka a nke ọma tupu ị na-anwa ịtọpụ, wụnye, ma ọ bụ rụọ ọrụ.
  • You may keep this quick guide for further reference.
  • kpachara anya: The product must be used indoors only.
  • kpachara anya: Edokwala unit ahụ nso mmiri mmiri ma ọ bụ n'ime oke damp gburugburu ebe obibi.
  • kpachara anya: Edokwala ngwaahịa a ozugbo na anyanwụ ma ọ bụ n'akụkụ ebe dị ọkụ.
  • kpachara anya: Ekwela ka mmiri mmiri ma ọ bụ ihe si mba ọzọ banye ngwaahịa a.
  • kpachara anya: Gbanye ngwaahịa ahụ site na iji oghere ala 2P +.
  • kpachara anya: Mgbe ị na-etinye ngwaahịa ahụ, hụ na nchikota nke mmiri iyi nke ngwaahịa na ngwaọrụ ndị ọ na-enye agaghị agafe 3.5mA.

Ntuziaka ojiji ngwaahịa

Nwụnye na nyocha ọrụ
Remove the unit from the shipping package and inspect for any damage. Contact the carrier if damage is found.

Rack Mount/Wall Mount the Unit
The module can be mounted to a 19″ enclosure or wall. Follow the provided instructions for installation.

Jikọọ na mpụga mgbidi
Plug the input power cord into the wall outlet. Power LED indicates normal mains power.

Jikọọ UPS
Connect UPS input/output cords to the corresponding sockets on the unit.

Operation Transfer to Maintenance Bypass
Ensure the Power LED is lit, switch the bypass switch from Normal to Bypass for the utility power supply.

Jikọọ Ngwa
Connect devices to the Master and Slave output receptacles based on power consumption requirements.

Nyefee na Nchedo UPS
After maintenance, reconnect UPS to the unit and switch the bypass from Bypass to Normal for UPS protection.

Ọrụ Nna-ukwu/Ohu
Enable/disable the Master/Slave function switch based on load requirements. Slave LED indicates load status.

Ajụjụ a na-ajụkarị

Q: How do I know if the unit is receiving power? A: The Power LED will indicate normal mains power by lighting up. Q: Can I mount the unit on a wall? A: Yes, the unit can be wall-mounted using the provided instructions. Q: What is the purpose of the Master/Slave function? A: The Master/Slave function helps in power saving by controlling power to peripherals based on the main device status.

The Power LED will indicate normal mains power by lighting up.

Can I mount the unit on a wall?

Yes, the unit can be wall-mounted using the provided instructions.

What is the purpose of the Master/Slave function?

The Master/Slave function helps in power saving by controlling power to peripherals based on the main device status.