1. Ngwaahịa gafereview
The BN-LINK CP-SU67D is an indoor astronomical digital programmable timer designed for automated control of various indoor appliances. It features up to 18 ON/OFF programs, astronomical timing for automatic sunrise/sunset adjustments, and support for six U.S. time zones. This timer also includes automatic Daylight Saving Time (DST) adjustment and an internal battery backup to retain settings during power outages.
Akụkụ ndị bụ isi:
- Astronomical Timing: Automatically adjusts ON/OFF times based on sunrise and sunset data.
- Multi-Zone Accuracy: Supports six U.S. time zones (PAC, MOU, CEN, EAS, HAW, ALA) for precise local scheduling.
- 18 ON/OFF Programs: Create up to 18 independent timer schedules for various devices.
- Nhazi oge dị mfe: Offers weekly and daily settings for comprehensive control.
- Ụdị arụ ọrụ: Easily switch between Auto, Manual, and Random modes.
- Ụdị enweghị usoro: Varies ON/OFF times by 0-30 minutes for enhanced security when away.
- DST Adjustment: Automatically shifts between standard and daylight saving time.
- Internal Battery Backup: Retains current time and program settings during power interruptions.
- Safe Power Rating: 125V 60Hz, 15A/1875W resistive, suitable for lamps, coffee makers, fans, and small indoor appliances.
Ọdịnaya ngwugwu:
- BN-LINK CP-SU67D Digital Programmable Timer
- Akwụkwọ ntuziaka onye ọrụ
2. Ntuziaka nchekwa dị mkpa
Please read and understand all instructions before using this product. Failure to follow these instructions may result in electric shock, fire, or serious personal injury.
- Eji ime ụlọ naanị: This timer is designed for indoor use in dry locations. Do not expose to rain, moisture, or wet conditions.
- Ọdụdọ Eletriki: Ekwela ka ọkụ eletrik gị gafere ọkwa 125V, 15A, 1875W. Ibufe ihe ngụ oge gabiga ókè nwere ike ibute oke okpomọkụ na ọkụ.
- Nda ala: Ensure the timer is plugged into a properly grounded 3-prong outlet.
- Ụmụaka: Debe ebe ụmụaka na-apụghị iru.
- Nhicha: Unplug the timer from the outlet before cleaning. Use a dry cloth only.
- Mbupu: Do not attempt to disassemble or repair the unit. Refer all servicing to qualified service personnel.
- Ngwa ndakọrịta: Ensure the appliance connected to the timer is suitable for unattended operation.
3. Ngwa ngwaahịa
Familiarize yourself with the various parts of your BN-LINK CP-SU67D timer:

- Ngosipụta ihuenyo: Shows current time, day, mode, and program settings.
- Bọtịnụ: Used for setting time, programs, and modes (SET, PROG, D/D, Reset, ON/OFF, +, -).
- Red Power Indicator Light: Na-enwu mgbe ngwaọrụ ahụ gbanyere ọkụ.
- Green Operation Indicator Light: Illuminates when the timer is actively controlling a connected device (e.g., turning it ON).
- Tinyekwa: Where you plug in the appliance to be controlled.
4. Mbido Mbido
4.1 Ịchaji batrị dị n'ime
Before first use, plug the timer into a live electrical outlet for at least 30 minutes to charge the internal battery. This battery maintains the clock and program settings during power outages ma ọ bụ mgbe agbanyụrụ ihe nkwụnye oge ahụ.
4.2 Clearing All Memory
To clear all previous settings and reset the timer to factory defaults, use a small pointed object (like a pen tip) to press the Tọgharia button located on the front of the timer. This is recommended for initial setup or if you encounter programming difficulties.
4.3 Ịtọ Oge na Ụbọchị Ugbu a
- Pịa ma jide SET button for 3 seconds until the clock display starts flashing.
- Jiri ihe + na - buttons to adjust the current hour.
- Pịa SET again to move to minute adjustment, then use + na -.
- Pịa SET again to move to day adjustment (MO, TU, WE, TH, FR, SA, SU), then use + na -.
- Pịa SET one last time to confirm and exit time setting mode.
4.4 Ịtọ oge Mpaghara
The timer supports six U.S. time zones for accurate astronomical timing. To set your time zone:

- Pịa ma jide D/D button for 3 seconds. The current time zone abbreviation will flash on the display.
- Jiri ihe + or - buttons to cycle through the available time zones (PAC, MOU, CEN, EAS, HAW, ALA).
- Once your desired time zone is displayed, press D/D ọzọ iji kwado na pụọ.
4.5 Daylight Saving Time (DST) Adjustment
The timer automatically adjusts for Daylight Saving Time. No manual reset is needed.

- To manually enable/disable DST, press and hold the + button for 3 seconds. The 'DST' indicator will appear or disappear on the display.
5. Ntuziaka ọrụ
5.1 Programming ON/OFF Events
The timer allows for up to 18 independent ON/OFF programs. Each program can be set for specific days of the week or daily.

- Pịa ỌRỤ button to enter program setting mode. The display will show '1 ON'.
- Jiri ihe + na - buttons to set the desired ON time for Program 1.
- Pịa ỌRỤ again. The display will show '1 OFF'.
- Jiri ihe + na - buttons to set the desired OFF time for Program 1.
- Pịa ỌRỤ again to select the days of the week for Program 1. Use + or - to cycle through options (e.g., MO TU WE TH FR SA SU, MO-FR, SA SU, individual days, etc.).
- Repeat steps 1-5 for up to 18 ON/OFF programs.
- Mgbe ịtọchara mmemme niile achọrọ, pịa SET button to exit program mode and return to the current time display.
5.2 Operating Modes (Auto, Manual, Random)
The timer offers three operating modes:

- Nchekwa onwe na ọnọdụ: The timer operates according to your programmed ON/OFF schedules. The display will show 'AUTO'.
- Ụdị akwụkwọ ntuziaka: Allows you to manually turn the connected appliance ON or OFF, overriding any programmed schedules. The display will show 'MAN'.
- Ụdị enweghị usoro: When enabled, this mode varies the programmed ON/OFF times by 0-30 minutes, simulating a 'lived-in' appearance for security purposes. The display will show 'RND'.
Iji gbanwee n'etiti ụdịdị, pịa bọtịnụ Gbanye/ Gbanyụọ button repeatedly until the desired mode (AUTO, MAN, RND) is displayed.


5.3 Astronomical Dusk to Dawn Feature
The timer can automatically adjust ON/OFF times based on local sunrise and sunset. This feature is active when the timer is in Auto mode and the time zone is correctly set. The display will show 'D/D' when this feature is active for a program.

6. Nlekọta
6.1 Nhicha
To clean the timer, first unplug it from the electrical outlet. Use a soft, dry cloth to wipe the exterior. Do not use liquid cleaners, aerosols, or harsh chemicals, as these may damage the unit or pose an electrical hazard.
6.2 Nchekwa
When not in use, store the timer in a cool, dry place, away from direct sunlight and extreme temperatures. Ensure the internal battery is charged periodically if stored for extended periods to maintain its functionality.
7. Nchọpụta nsogbu
If you encounter issues with your BN-LINK CP-SU67D timer, refer to the following common problems and solutions:
- Timer not turning ON/OFF at programmed times:
- Gbaa mbọ hụ na ihe nhazi oge dị na ya AUTO ọnọdụ.
- Verify that the programmed ON/OFF times and days are correct.
- Check if the internal battery is sufficiently charged (plug in for 30 minutes).
- Confirm the connected appliance is working correctly when plugged directly into an outlet.
- Ngosipụta ahụ tọgbọ chakoo ma ọ bụ gbaa ọchịchịrị:
- Plug the timer into a live outlet to charge the internal battery.
- If the issue persists, the internal battery may need replacement or the unit may be faulty.
- Difficulty programming the timer:
- Perform a full reset by pressing the Tọgharia bọtịnụ nwere ihe a kapịrị ọnụ.
- Carefully follow the programming steps in Section 5.1. The sequence of button presses is crucial.
- Ensure you are pressing SET to confirm each step (hour, minute, day) during time setting.
- To delete an unwanted program, navigate to that program number in PROG mode and set both ON and OFF times to '--:--' or reset the entire unit.
- Astronomical timing is inaccurate:
- Verify that the correct time zone is selected (refer to Section 4.4).
- Ensure the current time and day are set accurately.
- Note that astronomical timing adjusts based on general sunrise/sunset data for the selected time zone, not specific latitude/longitude.
- Random mode not working:
- Gbaa mbọ hụ na ihe nhazi oge dị na ya RND ọnọdụ.
- Random mode only applies to programmed ON/OFF events, not manual operation.
8. Nkọwapụta
| Oke | Uru |
|---|---|
| Nọmba nlereanya | CP-SU67D |
| Ogo Voltage | 125V AC, 60 Hz |
| Oke. Na-ebugo | 15A / 1875W (Resistive or General Purpose) |
| Ihe onwunwe | Plastic |
| Akụkụ ngwaahịa | 2.5"D x 2.5"W x 4.3"H |
| Ibu Ibu | 4.8 ounces |
| Ọnụọgụ nke Mmemme | Up to 18 ON/OFF programs |
| Batrị | 1 Nonstandard Battery (included, for backup) |


9. Akwụkwọ ikike na nkwado
9.1 Ozi akwụkwọ ikike
BN-LINK products are designed to provide reliable performance. For specific warranty details regarding your CP-SU67D timer, please refer to the warranty card included with your purchase or visit the official BN-LINK websaịtị.
9.2 Nkwado ndị ahịa
If you have any questions, require assistance with setup, or encounter issues not covered in this manual, please contact BN-LINK customer support. Contact information can typically be found on the product packaging or the official BN-LINK websaịtị.
- Nkwado n'ịntanetị: Visit the BN-LINK official websaịtị maka Ajụjụ Ndị A Na-ajụkarị, ndebanye aha ngwaahịa, na akụrụngwa nkwado.
- Nkwado email: Refer to your product packaging or the webebe nrụọrụ weebụ maka adreesị ozi-e ọrụ ndị ahịa.





