1. Okwu mmalite
Thank you for choosing the EMOS TSS910A Photoelectric Smoke Detector. This manual provides essential information for the safe and effective installation, operation, and maintenance of your smoke detector. Please read these instructions carefully before use and retain them for future reference.
The EMOS TSS910A is designed to provide early warning of fire by detecting smoke particles. It features a photoelectric sensor, an 85 dB acoustic alarm, and an optical LED warning light, ensuring reliable detection and alerting. With its 10-year lifespan and included 9V battery, it offers long-term safety for your home or office.
2. Ozi nchekwa
- Ihe nchọpụta anwụrụ ọkụ a bụ maka ojiji n'ime ụlọ naanị.
- Do not paint the smoke detector. Paint can clog the sensing chambers and prevent the alarm from functioning correctly.
- Etinyela ya n'ebe nwere oke iru mmiri, oke okpomọkụ, ma ọ bụ oke uzuzu.
- Regularly test the smoke detector as described in the operating instructions.
- Never ignore a smoke alarm. Investigate the cause and take appropriate action immediately.
- Keep out of reach of children unless installed securely.
- Tụfuo batrị na ngwaọrụ ahụ dịka iwu obodo si dị.
3. Ihe ngwugwu
Gbaa mbọ hụ na ihe niile dị na ngwugwu:
- 1 x EMOS TSS910A Smoke Detector
- 1 x 9V Battery (Alkaline)
- Ihe mgbakwasị ụkwụ na ihe nkwụnye mgbidi
- Akwụkwọ ntuziaka (akwụkwọ a)
4. Ngwaahịa gafereview
Familiarize yourself with the components of your EMOS TSS910A smoke detector:

This image displays the EMOS TSS910A smoke detector from the front and side, highlighting key features. The front view shows the acoustic alarm vents, the optical alarm LED, and the central test button. An inset image shows the battery compartment. Dimensions are also provided: 101 mm diameter and 36 mm height.
- Bọtịnụ ule: Press to test the alarm function.
- Optical LED: Flashes periodically during normal operation and rapidly during an alarm.
- Acoustic Alarm: Emits an 85 dB sound during an alarm.
- Akụkụ batrị: Located on the rear for the 9V battery.
- Efere Nkwanye: Detachable plate for ceiling or wall installation.
5. Ntọala na nwụnye
5.1 Ịhọrọ ebe
For optimal protection, install smoke detectors in every sleeping area and on every level of your home, including the basement. Consider these guidelines:
- Install on the ceiling in the center of a room or hallway.
- If wall-mounted, the top of the alarm should be 10-30 cm (4-12 inches) below the ceiling.
- Keep away from corners (at least 50 cm / 20 inches from walls).
- Avoid installing near windows, doors, or air vents where drafts could interfere with smoke detection.
- Do not install in kitchens, bathrooms, or garages where cooking fumes, steam, or exhaust fumes could cause false alarms.

This image shows the EMOS TSS910A smoke detector mounted on a ceiling, demonstrating a typical installation scenario in a residential setting. The detector is centrally placed on the ceiling, blending with the room's decor.
5.2 Ntinye batrị
- Twist the smoke detector counter-clockwise to detach it from the mounting plate.
- Chọta ebe batrị dị n'azụ ihe nchọpụta ahụ.
- Connect the included 9V alkaline battery to the battery clip, ensuring correct polarity (+ to + and - to -).
- Tinye batrị n'ime oghere.
- Reattach the smoke detector to the mounting plate by aligning the marks and twisting clockwise until it clicks into place.

This image illustrates the open battery compartment of the EMOS TSS910A smoke detector, clearly showing the terminals for the 9V battery. This visual aid helps users correctly install the battery.
5.3 Ịtinye ihe nchọta
- Once the battery is installed, hold the mounting plate against the chosen ceiling or wall location.
- Mark the positions for the two screw holes.
- Drill two holes at the marked positions. Insert the wall plugs if necessary.
- Secure the mounting plate with the provided screws.
- Attach the smoke detector to the secured mounting plate by aligning the marks and twisting clockwise until it locks firmly.
- After mounting, press the test button to ensure the alarm functions correctly.
6. Ntuziaka ọrụ
6.1 Ọrụ nkịtị
Once installed with a fresh battery, the smoke detector is active. The optical LED will flash approximately once every 40-60 seconds to indicate normal operation.
6.2 Testing the Alarm
It is crucial to test your smoke detector weekly to ensure it is functioning correctly. To test:
- Press and hold the large central Bọtịnụ nwale on the front of the detector for a few seconds.
- The alarm will sound loudly (85 dB), and the LED will flash rapidly.
- Hapụ bọtịnụ ahụ. Mkpu mkpu ahụ kwesịrị ịkwụsị.
- Ọ bụrụ na mkpu ahụ adaghị, gaa na ngalaba Nchọpụta Nsogbu.
6.3 Ngosipụta mkpu
- Mkpu anwụrụ ọkụ: When smoke is detected, the alarm will sound continuously (85 dB), and the red LED will flash rapidly.
- Ịdọ aka ná ntị batrị dị ala: The detector will chirp approximately once every 30-40 seconds, and the LED will flash simultaneously, indicating that the battery needs to be replaced. This warning will continue for about 30 days.
7. Nlekọta
7.1 nnọchi batrị
When the low battery warning sounds (a chirp every 30-40 seconds), replace the 9V battery immediately. Use only alkaline 9V batteries. To replace:
- Twist the smoke detector counter-clockwise to remove it from the mounting plate.
- Disconnect the old 9V battery from the clip and remove it.
- Connect a new 9V alkaline battery, ensuring correct polarity.
- Place the new battery into the compartment.
- Reattach the smoke detector to the mounting plate by aligning the marks and twisting clockwise until it clicks into place.
- Test the alarm using the test button after battery replacement.
7.2 Cleaning Your Smoke Detector
Dust and debris can accumulate on the smoke detector and affect its performance. Clean your detector at least once a month:
- Gently vacuum the exterior of the smoke detector using a soft brush attachment.
- Wipe the cover with a slightly damp akwa . Ejila ihe nhicha ma ọ bụ ihe mgbaze.
- Etinyela ihe nchọpụta anwụrụ ọkụ agba.
7.3 Ogologo ndụ
The EMOS TSS910A smoke detector has a 10-year operational lifespan. After 10 years from the manufacturing date (usually printed on the device), the entire unit should be replaced, even if it appears to be working correctly.

This image emphasizes the 10-year safety feature of the EMOS TSS910A smoke detector, shown installed on a ceiling. The long lifespan of the sensor and the low battery warning ensure continuous operation and safety.
8. Nchọpụta nsogbu
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Mkpu anaghị ada ụda n'oge ule. | Batrị nwụrụ anwụ ma ọ bụ arụnyere na ezighi ezi. | Check battery polarity. Replace with a new 9V alkaline battery. |
| Ihe nchọpụta na-akpọ mkpu kwa sekọnd 30-40. | Ịdọ aka ná ntị batrị dị ala. | Dochie batrị 9V ozugbo. |
| False alarms occur frequently. | Improper location (e.g., near kitchen, bathroom, or dusty area). Dust accumulation. | Relocate the detector to a more suitable area. Clean the detector as per maintenance instructions. |
| LED does not flash during normal operation. | Dead battery or unit malfunction. | Replace battery. If problem persists, the unit may need replacement. |
9. Nkọwapụta
| Njirimara | Nkọwa |
|---|---|
| Nọmba nlereanya | TSS910A |
| Ụdị ihe mmetụta | Igwe ọkụ |
| Olu mkpu | 85 dB |
| Isi Iyi Ike | Batrị Alkaline 1 x 9V (gụnyere) |
| Nrụ ọrụ Voltage | 9V |
| Ogologo ndụ | afọ 10 |
| Akụkụ (D x H) | 10.1 x 3.6 cm (4 x 1.4 sentimita) |
| Ibu | 190g (0.42 lbs) |
| Ihe onwunwe | Plastic |
| Agba | Ọcha |
| Iru mmiri na-arụ ọrụ | 5% ruo 95% RH (na-abụghị condensing) |
10. Akwụkwọ ikike na nkwado
EMOS products are manufactured to high-quality standards. For warranty information, technical support, or service inquiries, please refer to the contact information provided with your purchase or visit the official EMOS websaịtị. Biko dowe ihe akaebe nke ịzụrụ ihe maka akwụkwọ ikike.