This manual provides essential information for the safe and efficient operation of your ACiQ 20 SEER2 Essentials 9000 BTU Mini Split AC/Heating System. This ductless heat pump system is designed to provide both cooling and heating for spaces approximately 250-400 sq. ft. in size, operating on 208/230V power.
Please read this manual thoroughly before installation, operation, or maintenance. Keep it for future reference.

Foto: Ofeview of the ACiQ Mini Split System, showing the indoor unit, outdoor condenser, remote control, and a smartphone interface for WiFi control.
2. Ozi nchekwa
- Achọrọ nwụnye ọkachamara: This unit is not a DIY installation. Installation, maintenance, and repair must be performed by a qualified, licensed HVAC professional. Improper installation can result in electric shock, fire, water leakage, or other hazards.
- Nchekwa Eletriki: Ensure the power supply matches the unit's requirements (208/230V). All electrical work must comply with local and national electrical codes. Disconnect power before servicing.
- Ijikwa friji: The unit contains R454B refrigerant. Only qualified personnel should handle refrigerant. Ensure proper ventilation during installation and servicing.
- Vacuuming Lines: The refrigerant lines must be properly evacuated (vacuumed) by a professional to remove air and moisture before operation. Failure to do so will void the warranty and can cause system damage.
- Nwepu: Debe oghere zuru oke gburugburu ma n'ime ụlọ ma n'èzí maka ikuku na mmezi kwesịrị ekwesị.
- Ụmụaka na anụ ụlọ: Debe ụmụaka na anụ ụlọ n'ebe a na-arụ ọrụ na nlekọta.
3. Gịnị gụnyere
Your ACiQ Mini Split System package includes the following components:

Image: A visual representation of all items included in the ACiQ Mini Split package, such as the indoor unit, outdoor unit, line set, remote, and various installation accessories.
- Ngalaba ime ụlọ (Onye njikwa ikuku)
- Ngalaba dị n'èzí (condenser)
- Njikwa anya
- 16ft Line Set (pre-charged for this length)
- Mgbidi okpu
- Ahịrị igbapu
- Ụdọ ọkụ
- Akụrụngwa mgbago (skru, arịlịka)
- AAA Batteries (for remote control)
- Akwụkwọ ntuziaka (akwụkwọ a)
- Additional small parts like rubber feet, plastic wrap, plasticine, and a remote mount.
4. Ntuziaka nwụnye
As stated in the safety information, installation of this ACiQ Mini Split System requires a qualified HVAC professional. The following points are general guidelines and not a substitute for professional expertise.
- Nhọrọ saịtị:
- Ime ụlọ: Choose a location that allows for optimal air distribution, sufficient wall strength to support the unit, and proper drainage. Avoid direct sunlight or heat sources.
- N'èzí: Select a stable, level surface with adequate clearance for airflow and maintenance. Avoid areas prone to excessive dust, debris, or direct exposure to strong winds.
- Ịkwanye: Securely mount the indoor unit to a wall using the provided mounting plate and hardware. The outdoor unit should be placed on a sturdy pad or wall bracket.
- Njikọ Ntọala ahịrị: Connect the pre-charged 16ft line set between the indoor and outdoor units. Ensure all connections are tight and leak-free.
- Ọkụ eletrik: Connect the power supply (208/230V) and communication wiring according to the wiring diagram provided in the full installation manual (included with the product) and local electrical codes.
- igbapu: Install the drain line with a continuous downward slope to ensure proper condensate removal.
- Ntupu: After all connections are made, the refrigerant lines must be evacuated using a vacuum pump to remove non-condensable gases and moisture. This step is critical for system performance and longevity.
- Leak Lelee: Perform a thorough leak check on all refrigerant connections.
- Nwale ọsọ: After installation, perform a test run to verify proper operation in both cooling and heating modes.
Ihe ndetu dị mkpa: The unit comes pre-charged with refrigerant for up to a 25ft line set. If your line set is shorter, a professional will still need to vacuum the lines. If a longer line set is used, additional refrigerant may be required, which must be added by a certified technician.
5. Ntuziaka ọrụ
5.1 Ọrụ njikwa anya
The remote control allows you to manage all functions of your ACiQ Mini Split System. Insert the provided AAA batteries before first use.

Image: Remote control features, illustrating icons for I Feel Mode, Sleep Mode, Eco Mode, Mute Mode, Timers, and Turbo Mode.
- Bọtịnụ ike: Gbanyụọ otu ahụ ma ọ bụ gbanyụọ.
- Bọtịnụ ụkpụrụ: Na-eme usoro site na ụdị ọrụ: Auto, Cool, Dry, Heat, Fan.
- Ndozi okpomọkụ: Jiri akụ Elu/Ala tọọ okpomọkụ achọrọ.
- Ọsọ onye ofufe: Adjusts the fan speed (Auto, Low, Medium, High).
- Bọtịnụ Swing: Controls the louver direction for optimal air distribution.
- Ọrụ ngụ oge: Set the unit to turn ON or OFF automatically after a specified period.
- Modera Modera: Na-agbanwe okpomọkụ na ọsọ fan maka ụra dị mma na ịchekwa ike.
- Ụkpụrụ Eco: Optimizes operation for energy efficiency.
- Ọnọdụ M Na-enwe Mmetụta: The remote control senses the temperature at its location and adjusts the unit's operation for localized comfort.
- Ụdị Turbo: Na-enye ngwa ngwa jụrụ oyi ma ọ bụ kpo oku iji ruo okpomọkụ achọrọ ngwa ngwa.
- Ọnọdụ ogbi: Reduces operational sounds for a quieter environment.
5.2 WiFi Control (Smart Device App)
Your ACiQ Mini Split System is equipped with built-in WiFi, allowing control via a smart device (iOS or Android) from anywhere. The app is compatible with Amazon Alexa, Google Assistant, and IFTTT.

Image: A user operating the ACiQ system remotely via a smartphone app, highlighting the WiFi control feature.
- Budata ngwa: Download the "Smart Life" app from your device's app store (iOS or Android).
- Debanye aha/Nbanye: Create an account or log in to the Smart Life app.
- Tinye ngwaọrụ: Follow the in-app instructions to add your ACiQ Mini Split System. This typically involves putting the unit into pairing mode (refer to the full manual for specific steps) and connecting it to your home WiFi network.
- Njikwa: Once connected, you can control all functions of the unit, including mode, temperature, fan speed, and scheduling, from your smartphone or tablet.
- Ngwakọta Smart Home: Link the Smart Life app with Amazon Alexa, Google Assistant, or IFTTT for voice control and advanced automation.
6. Nlekọta
Regular maintenance ensures optimal performance and longevity of your ACiQ Mini Split System. Always disconnect power to the unit before performing any maintenance.
- Air Filter Cleaning (Monthly):
- Mepee akụkụ ihu nke ime ụlọ.
- Wepu ihe nzacha ikuku.
- Clean filters with a vacuum cleaner or wash them with lukewarm water. Allow them to dry completely before reinstalling.
- Indoor Unit Cleaning (Periodically): Jiri ihe dị nro, d hichaa mpụta nke ihe dị n'ime ụlọ ahụ.amp akwa . Ejila kemịkalụ siri ike ma ọ bụ ihe mkpocha abrasive.
- Outdoor Unit Cleaning (Seasonally):
- Clear any debris (leaves, dirt, grass) from around the outdoor unit.
- Gently rinse the condenser coils with a garden hose to remove accumulated dirt. Be careful not to bend the fins.
- Drain Line Check (Seasonally): Ensure the condensate drain line is clear and free of obstructions to prevent water leakage.
- Nyocha ndị ọkachamara (kwa afọ): It is recommended to have a qualified HVAC technician inspect your system annually. This includes checking refrigerant levels, electrical connections, and overall system performance.
7. Nchọpụta nsogbu
Tupu ị kpọtụrụ ndị ahịa, biko lee nsogbu na ngwọta ndị a na-ahụkarị.
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Unit anaghị agbanwuo. | Enweghị ike, batrị dịpụrụ adịpụ anwụọla, ihe mgbawa sekit adaala. | Lelee ọkọnọ ike, dochie batrị ndị dịpụrụ adịpụ, tọgharịa ihe mgbawa sekit. |
| Ezughi oke jụrụ oyi/ọkụ. | Dirty air filters, blocked outdoor unit, wrong mode selected, temperature setting incorrect, low refrigerant. | Clean air filters, clear outdoor unit, select correct mode, adjust temperature, contact professional for refrigerant check. |
| Mwepu mmiri sitere na nkeji ime ụlọ. | Ahịrị mmiri akpọchiri akpọchi, ntinye na-ezighi ezi. | Lelee ma hichaa eriri mmiri ozuzo, kpọtụrụ ọkachamara maka nyocha. |
| Mkpọtụ na -adịghị ahụkebe. | Akụkụ rụrụ arụ, ihe mgbochi fan, okwu compressor. | Turn off unit and inspect for obstructions. If noise persists, contact professional. |
| Njikwa anya anaghị arụ ọrụ. | Batrị nwụrụ anwụ, ihe mgbochi n'etiti ime na unit, arụghị ọrụ nke ọma. | Replace batteries, remove obstructions, try resetting the remote. |
For issues not listed here or if solutions do not resolve the problem, please contact ACiQ customer support or a qualified HVAC technician.
8. Nkọwapụta

Image: Technical specifications and dimensions for the ACiQ Mini Split Indoor and Outdoor Units.
| Njirimara | Nkọwa |
|---|---|
| Nọmba nlereanya | ACiQ-K09W-W-HP230B / ACiQ-K09Z-HP230B |
| Ike | 9,000 BTU (0.75 ton) |
| SEER2 Efficiency | 20.0 |
| Ịnye ọkụ | 230V~ / 60Hz / 1Ph |
| Oke arụ ọrụ jụrụ oyi | 5°F to 122°F outdoor temperature |
| Oke arụ ọrụ kpo oku | -4°F to 86°F outdoor temperature |
| Estimated Coverage Area | 250-400 sq ft |
| Akụkụ ime ụlọ (H x W x D) | 7.99" x 31.92" x 11.49" |
| Akụkụ dị n'èzí (H x W x D) | 19.60" x 30.98" x 11.41" |
| Ọkwa mkpọtụ ime ụlọ | Dị obere ka 28 dBA |
| Typedị Refrigerant | R454B |
| Atụmatụ pụrụ iche | Built-in WiFi, Ultra-quiet operation, Full installation kit, Heats in -4°F temps |
9. Akwụkwọ ikike na nkwado
ACiQ provides a comprehensive warranty for your peace of mind.

Image: ACiQ warranty details, indicating 6-year compressor and 4-year parts coverage.
- Akwụkwọ ikike Compressor: afọ 6
- Akwụkwọ ikike nke akụkụ: afọ 4
- Ndebanye akwụkwọ ikike: To activate your warranty, you must register your system online with the manufacturer at ACiQ.com. Failure to register may affect warranty coverage.
- Nkwado: For technical assistance, warranty claims, or service inquiries, please visit the official ACiQ websaịtị ma ọ bụ kpọtụrụ nkwado ndị ahịa ha ozugbo.
Biko dowe ihe akaebe nke ịzụrụ ihe maka ebumnuche ikike.