Fluke FLUKE-107

Fluke 107 AC/DC Current Handheld Digital Multimeter User Manual

Model: FLUKE-107

Okwu mmalite

The Fluke 107 is a compact, handheld digital multimeter designed for basic electrical measurements. It provides accurate readings for voltage, current, resistance, capacitance, frequency, and duty cycle, along with continuity and diode test functions. Its portable design makes it suitable for various applications, from professional use to hobbyist projects.

Fluke 107 Digital Multimeter front view

Foto: N'ihu view of the Fluke 107 Digital Multimeter, displaying its screen, rotary dial, and function buttons.

Ozi nchekwa

Always adhere to safety precautions when using any electrical testing equipment. Failure to do so may result in injury or damage to the meter or equipment under test.

Kedu ihe dị na Igbe ahụ

The Fluke 107 package typically includes the following components:

Fluke 107 Multimeter with test leads and magnetic strap

Image: The Fluke 107 Multimeter displayed alongside its included test leads and magnetic lanyard.

Melite

Ntinye batrị

The Fluke 107 comes with two AAA batteries pre-installed. If replacement is needed:

  1. Hụ na agbanyụrụla multimeter ahụ.
  2. Chọta ebe batrị dị n'azụ mita ahụ.
  3. Open the battery compartment cover by twisting the lock and sliding it open.
  4. Remove the old batteries and insert two new AAA batteries, observing the correct polarity (+/-).
  5. Mechie mkpuchi nke batrị batrị nke ọma.

Ijikọ ule na-eduga

The Fluke 107 has three recessed banana jacks:

Always connect the black test lead to the COM jack. Connect the red test lead to the appropriate jack based on the measurement you intend to perform.

Using the Smart Strap Magnetic Lanyard

The included Smart Strap allows for hands-free operation by attaching the meter to a ferrous metal surface or by configuring it as a stand. The strap has a slot that fits into the meter's case and secures with Velcro. The magnetic end can then be used to attach the meter to metal surfaces or to itself to form a viewing stand.

Ntuziaka ọrụ

Njikwa agafelaview

The Fluke 107 features a central rotary selector knob and three soft-touch buttons:

Hand in glove operating Fluke 107 Multimeter

Image: A gloved hand adjusting the rotary dial of the Fluke 107 Multimeter, demonstrating its ergonomic design.

Ọrụ Nnwale

The meter is auto-ranging by default for most functions, simplifying operation.

  1. VoltagNha eletrọniki (AC/DC):
    • Tụgharịa igodo rotary ka V~ maka AC voltage ma ọ bụ V- maka DC voltage.
    • Connect the red test lead to the VΩHz jack and the black test lead to the COM jack.
    • Apply the test probes across the circuit or component to measure voltage.
  2. Current Measurement (AC/DC):
    • Tụgharịa igodo rotary ka A~ (AC) or A- (DC). Use the yellow button to toggle between AC and DC if needed.
    • Connect the red test lead to the A (10A FUSED) jack and the black test lead to the COM jack.
    • Ihe dị mkpa: Connect the meter in series with the circuit to measure current. Ensure the circuit is de-energized before connecting the meter.
  3. Nledo Nguzogide (Ω):
    • Tụgharịa igodo rotary ka Ω.
    • Connect the red test lead to the VΩHz jack and the black test lead to the COM jack.
    • Apply the test probes across the component. Ensure the circuit is de-energized.
  4. Nnwale na-aga n'ihu:
    • Tụgharịa igodo rotary ka Ω. Press the yellow button until the continuity icon (speaker symbol) appears.
    • Connect the red test lead to the VΩHz jack and the black test lead to the COM jack.
    • A continuous beep indicates a complete circuit (resistance less than 70Ω). "OL" indicates an open circuit.
  5. Nnwale Diode:
    • Tụgharịa igodo rotary ka Ω. Press the yellow button until the diode icon (arrow with line) appears.
    • Connect the red test lead to the VΩHz jack and the black test lead to the COM jack.
    • Place the red probe on the anode and black probe on the cathode of the diode. The display shows the forward voltage drop. Reverse the probes; "OL" should be displayed for a good diode.
  6. Nleba ike:
    • Turn the rotary knob to the capacitance symbol (-||-).
    • Connect the red test lead to the VΩHz jack and the black test lead to the COM jack.
    • Ihe dị mkpa: Discharge capacitors before connecting them to the meter. Apply probes across the capacitor. Readings may take up to 18 seconds to stabilize.
  7. Frequency (Hz) and Duty Cycle (%) Measurement:
    • Select AC Volts or AC Amps ọrụ.
    • Pịa Hz% button to display frequency. Press again for duty cycle. Press a third time to return to voltage/current display.

Nchekwa onwe-Off

The meter automatically powers off after 20 minutes of inactivity to conserve battery life. This feature can be disabled if continuous operation is required.

Nlekọta

Nhicha

Jiri mgbasa ozi hichapụ ikpe ahụamp cloth and mild detergent. Do not use abrasives or solvents. Keep the display clean and free from scratches.

Ngbanwe batrị

Refer to the "Battery Installation" section under Setup for detailed instructions. Replace batteries when the low battery indicator appears on the display.

Fuse Check and Replacement

The Fluke 107 has a single internal fuse for the Amps function. To check the fuse:

  1. Tụgharịa ngbanwe nke nhọrọ na Ω ọnọdụ.
  2. Plug the red test lead into the VΩHz jack.
  3. Insert the probe tip of the red test lead into the A (10A FUSED) jack until electrical contact is made.
  4. A reading of less than 0.5Ω indicates a good fuse. An "OL" reading indicates a blown fuse that requires replacement.

Fuse replacement requires opening the meter case by removing three screws. It is recommended that fuse replacement be performed by qualified personnel or a Fluke service center.

Nchọpụta nsogbu

NsogbuIhe nwere ike imeNgwọta
Egosipụtara "OL" (Oke ibu)Input value exceeds selected range; open circuit in continuity/diode test; blown fuse in current mode.Ensure correct function/range is selected. Check for open circuits. Check fuse in current mode.
Enweghị ngosipụta ma ọ bụ ngosipụta dị jụụLow battery; meter off; damaged display.Replace batteries. Turn meter ON. Contact service if display is damaged.
Ọgụgụ na-ezighi eziLow battery; incorrect function/range; poor test lead connection; external interference.Replace batteries. Verify function/range. Ensure leads are fully inserted. Move away from strong electromagnetic fields.
No current measurementBlown fuse; incorrect connection (not in series).Check and replace fuse if necessary. Ensure meter is connected in series with the circuit.

Nkọwapụta

OkeUru
Max Voltage n'etiti ihe ọ bụla ọnụ na ala ala600V
Ngosipụta Ọnụego Mmelite3 updates per second
Ụdị batrị2 x AAA batteries (Alkaline or Lithium recommended)
Ndụ batrị200 awa kacha nta
Okpomọkụ na-arụ ọrụ0°C ruo 40°C (32°F ruo 104°F)
DC Volts Ranges6.000V, 60.00V, 600.0V (Accuracy: 0.5% + 3 counts)
AC Volts Ranges6.000V, 60.00V, 600.0V (Accuracy: 1% + 3 counts)
ACmV Range600.0mV (Accuracy: 3% + 3 counts)
DC Amps Ranges4.000A, 10.00A (Accuracy: 1.5% + 3 counts)
AC Amps Ranges4.000A, 10.00A (Accuracy: 1.5% + 3 counts)
Oke mgbochi400.0Ω, 4.000kΩ, 40.00kΩ, 400.0kΩ, 4.000MΩ, 30.00MΩ (Accuracy: 0.5% + 2 or 3 counts, 1.5% + 3 counts for 40MΩ)
Capacitance Ranges50.00nF, 500.0nF, 5.000µF, 50.00µF, 500.0µF, 1000µF (Accuracy: 2% + 5 counts on two lowest, 5% + 5 counts on higher)
Ugboro ugboro50.00Hz, 500.0Hz, 5.000kHz, 50.00kHz, 100.0kHz (Accuracy: 0.1% + 3 counts)
Usoro ọrụ1% ~ 99% (Accuracy: 1% typical)
Diode Test Range2.000V (Accuracy: 10%)
Akụkụ ngwaahịa8.27 x 11 x 2.17 inch; 7.05 ounce

Akwụkwọ ikike na nkwado

The Fluke 107 Digital Multimeter comes with a 1-year manufacturer warranty. For warranty claims, technical support, or service, please contact Fluke customer service or visit the official Fluke website. Ensure you have your product model number and purchase details available.

For additional resources and detailed user manuals, please refer to the official Fluke support channels.

Akwụkwọ ndị emetụtara - FLUKE-107

Tupuview Fluke 107 Handheld CAT III Digital Multimeter - Technical Specifications
Detailed technical specifications, features, and general information for the Fluke 107 handheld CAT III digital multimeter. Includes electrical measurements, safety ratings, and ordering details.
Tupuview Fluke 107 CAT III Digitale Multimeter Specificaties en Kenmerken
Gedetailleerde specificaties, kenmerken en technische gegevens voor de Fluke 107 CAT III digitale multimeter in handpalmformaat. Inclusief elektrische en algemene specificaties, afmetingen, garantie en informatie over EURO-INDEX diensten.
Tupuview Fluke 106/107 Palmsized Digital Multimeters: Technical Specifications and Features
Detailed technical specifications, product highlights, and general information for the Fluke 106 and 107 palmsized digital multimeters. Learn about their electrical specifications, accuracy, features, and included equipment.
Tupuview Akwụkwọ ntuziaka onye ọrụ Fluke 106/107 Digital Multimeters
Akwụkwọ ntuziaka onye ọrụ zuru oke maka Fluke 106 na 107 Digital Multimeters, na-ekpuchi ozi nchekwa, ngwaọrụ karịrịview, nha, mmezi, na nkọwapụta.
Tupuview Ngwa nkwụnye Fluke FEV100 maka ọdụ ụgbọ ala eletrik: Data nka na nkọwapụta.
Chọgharịa nkọwa nka, atụmatụ na usoro nnwale maka Fluke FEV100 Adapter Kit, emebere iji nwalee ọdụ ụgbọ eletrik nke ọma na nke ọma (EVSE). Gụnyere ozi nchekwa, ndakọrịta, na nkọwa nhazi.
Tupuview Fluke 110 True-RMS Multimeter: Technical Specifications and Features
Detailed specifications and features of the Fluke 110 compact True-RMS multimeter, designed for precise electrical installation and troubleshooting. Includes accuracy, safety ratings, and included accessories.