UNI-T A56 BT

Akwụkwọ ntuziaka onye ọrụ UNI-T A56 BT okpomọkụ iru mmiri

Models: A56 BT, A57 BT

1. Okwu mmalite

The UNI-T A56 BT and A57 BT are advanced temperature and humidity dataloggers designed for precise environmental monitoring. These devices feature a large data storage capacity of 64,000 sets, Bluetooth connectivity for seamless communication with PC and mobile applications, and robust IP54 protection. They are ideal for various applications requiring accurate and reliable temperature and humidity data logging, such as food processing, cold-chain transportation, and warehouse monitoring.

2. Atụmatụ igodo

  • Oke izi ezi: Measures temperature with an accuracy of ±0.3°C and humidity with ±2.5%RH.
  • Nchekwa Data buru ibu: Capable of storing up to 64,000 sets of temperature and humidity data.
  • Njikọ Bluetooth: Enables wireless data transfer and configuration via Bluetooth to a mobile application (TempLink) or PC analysis software.
  • Audible and Visible Alarm: Provides alerts for out-of-limit temperature and humidity conditions.
  • Nchekwa IP54: Offers protection against dust and splashing water, suitable for various environments.
  • Magnetic Wall-Mounted Design: Allows for flexible and secure placement.
  • Adjustable Record Interval: Logging intervals can be set from 10 seconds to 24 hours.
  • Nkwado ọtụtụ asụsụ: User interface available in English, French, German, Italian, Spanish, Swedish, Polish, and Czech.
  • Ogologo ndụ batrị: Powered by a single-use Li-ion battery (3.6V 2700mAh ER14505) with up to 2 years of life (room temperature, 15min record interval).
Infographic showing key features of UNI-T A56 BT Datalogger

Nyocha 2.1: N'eluview of UNI-T A56 BT Datalogger key features including Bluetooth APP, 64000 Data Storage, High Accuracy, PC Analysis Software, Audible and Visible Alarm, and Waterproof Dustproof (IP54).

Infographic showing display, temperature range, record interval, alarm, and mounting options

Figure 2.2: Detailed features including simultaneous large-screen display, wide measurement range (-40°C to 85°C), adjustable record interval, over-limit alarm, and magnetic wall-mounted design.

3. Nhazi

3.1. Nyocha mbụ

Upon unpacking, verify that all components are present and undamaged. The package typically includes the A56 BT datalogger, a gift box, a quick start guide, a safety instruction, download operation guide, battery, wall-mounted screws*2, expandable rubber plug*2, and a USB cable.

3.2. Ntinye batrị

The datalogger uses a single-use Li-ion battery (3.6V 2700mAh ER14505). Refer to the quick start guide for specific instructions on how to open the battery compartment and correctly insert the battery. Ensure proper polarity.

3.3. Nwụnye ngwanrọ

Download the UNI-T TempLink mobile application from your device's app store or the PC analysis software from the official UNI-T websaịtị. Soro ntuziaka na ihuenyo maka nwụnye.

3.4. Mounting the Datalogger

The A56 BT features a magnetic wall-mounted design. Choose a suitable location for monitoring, ensuring it is within Bluetooth range of your control device if wireless operation is desired. Use the provided screws and plugs for secure wall mounting if needed.

N'ihu view of UNI-T A56 BT Datalogger showing display

Foto 3.1: N'ihu view of the A56 BT Datalogger, displaying current temperature and humidity readings.

4. Ntuziaka ọrụ

4.1. Ijikọ site na Bluetooth

  1. Ensure Bluetooth is enabled on your smartphone or PC.
  2. Open the TempLink app or PC software. The software will automatically search for nearby A56 BT/A57 BT dataloggers.
  3. Select your datalogger from the list of discovered devices to establish a connection.

4.2. Configuring Logging Parameters

Using the TempLink app or PC software, you can configure various logging parameters:

  • Interbanye abanye: Set how frequently data is recorded (e.g., 10s, 1min, 1h).
  • Oti mkpu: Define upper and lower limits for temperature and humidity to trigger audible and visual alarms.
  • Start/Stop Logging: Initiate or terminate data recording.
  • Nhọrọ nkeji: Choose between °C and °F for temperature display.

4.3. Ịmalite na Ịkwụsị Ndekọ Data

Once configured, you can start logging directly from the app/software. The datalogger will begin recording data at the specified interval. To stop logging, use the corresponding function in the application.

4.4. Data Retrieval and Analysis

After logging, connect the datalogger to the TempLink app or PC software. You can then download the recorded data. The software allows for graphical analysis of the data and export into various formats such as XLSX (Excel), CSV, or TXT for further processing.

Infographic showing data storage, Bluetooth connection, and report generation

Figure 4.1: Illustration of the datalogger's capabilities, including 64000 data storage, Bluetooth APP and PC software support, and automatic generation of multiple report forms (PDF, CSV).

5. Nlekọta

5.1. Ngbanwe batrị

When the battery indicator on the display shows low power, replace the battery promptly to ensure continuous operation and data integrity. Use only the specified battery type (3.6V 2700mAh ER14505 Li-ion battery).

5.2. Nhicha

Wipe the datalogger with a soft, dry cloth. Do not use abrasive cleaners or solvents. While the device has IP54 protection, avoid submerging it in water or exposing it to excessive moisture.

5.3. Nchekwa

Store the datalogger in a cool, dry place away from direct sunlight and extreme temperatures when not in use for extended periods. Remove the battery if storing for several months to prevent leakage.

6. Nchọpụta nsogbu

  • Ngwaọrụ anaghị ejikọ site na Bluetooth: Ensure the datalogger is powered on and within range (up to 100 feet). Check that Bluetooth is enabled on your smartphone or PC. Restart both the datalogger and the application.
  • Ọgụgụ na-ezighi ezi: Verify that the datalogger is placed in an environment free from direct heat sources, strong air currents, or excessive moisture that could affect sensor performance. Ensure the sensor opening is not obstructed.
  • Data logging not starting: Confirm that logging parameters have been correctly configured and the 'Start' command has been issued through the application. Check battery level.
  • Ngosipụta anaghị arụ ọrụ: Check the battery level and replace if necessary. If the issue persists, contact customer support.

7. Nkọwapụta

Table of UNI-T A56 BT Datalogger functions and specifications

Figure 7.1: Detailed table of functions, ranges, accuracy, and other characteristics of the A56 BT Datalogger.

NjirimaraNkọwapụta
Ụdị ngwaahịaYH-A56 BT
Oke okpomọkụ-40°C ~ 85°C (-40°F ~ 185°F)
Okpomọkụ ziri ezi±0.3°C (0°C < t ≤ 60°C)
Oke iru mmiri0% ~ 100% RH
Ikike iru mmiri±2.5%RH (0% ≤ RH ≤ 90%)
Ike ndekọ64,000 setịpụ
Ogologo oge ndekọ10s ~ 24h (Adjustable via App/PC)
NjikọtaBluetooth APP (TempLink), PC Analysis Software
Oti mkpuAudible and Visible
Ogo nchekwaIP54
Ụdị batrịSingle-use Li-SOCl2 Battery 3.6V 2700mAh (ER14505)
Oge ọrụ2 years (Room temperature, 15min record interval, screen off, indicators/Bluetooth off)
ỊkwanyeIgwe ndọta azụ ma ọ bụ mgbakwasị mgbidi
Nha ngwaahịa104 x 62 x 25 mm
Arọ Net NgwaahịaIhe dịka 110g
Akụkụ ngwaahịa6.5 x 4.33 x 4.72 sentimita asatọ
Ibu Ibu2.2 pound (ihe dị ka 1 n'arọ)
Onye nrụpụtaUsoro UNI

8. Akwụkwọ ikike na nkwado

Warranty information for the UNI-T A56 BT/A57 BT Temperature Humidity Datalogger is typically provided with the product packaging or available on the official UNI-T websaịtị. Biko lee akụrụngwa ndị a maka usoro na ọnọdụ nkwa zuru ezu.

For technical support, product inquiries, or service, please visit the official UNI-T website or contact their customer service department through the contact information provided in your product documentation.

Akwụkwọ ndị emetụtara - A56 BT

Tupuview UNI-T A57 BT Bluetooth Temperature Humidity Datalogger User Manual
Comprehensive user manual for the UNI-T A57 BT Bluetooth Temperature Humidity Datalogger, detailing its features, operation, specifications, safety guidelines, and software integration for accurate temperature and humidity monitoring.
Tupuview UNI-T UT330 Series USB Datalogger: User Manual and Specifications
Comprehensive user manual for the UNI-T UT330T, UT330TH, and UT330THC USB Temperature and Humidity Dataloggers. Features include operation, specifications, maintenance, and software/app setup.
Tupuview UNI-T UT330A/B/C USB Datalogger Operation Manual - Temperature, Humidity, Pressure Monitoring
Comprehensive operation manual for the UNI-T UT330A, UT330B, and UT330C USB dataloggers. Learn about features, safety, usage, maintenance, and technical specifications for accurate environmental data logging.
Tupuview UNI-T UT331+/UT332+ Digital Temperature & Humidity Meter User Manual
Comprehensive user manual for the UNI-T UT331+ and UT332+ digital temperature and humidity meters, covering features, operation, safety, maintenance, and technical specifications.
Tupuview UNI-T UT331+/UT332+ Digital Temperature Humidity Meter Manual
Comprehensive user manual for UNI-T UT331+ and UT332+ digital temperature and humidity meters. Learn about features, operation, safety, data logging, and maintenance.
Tupuview Akwụkwọ ntuziaka onye ọrụ UNI-T UT333S Digital okpomọkụ iru mmiri
User manual for the UNI-T UT333S Digital Temperature Humidity Meter, covering features, specifications, safety information, structure, symbols, buttons, and maintenance.