AUTOOL LM 120

AUTOOL LM 120 Digital Manifold Gauge Meter User Manual

Model: LM 120

1. Okwu mmalite

The AUTOOL LM120+ Refrigeration Digital Manifold Gauge Meter is an intelligent electronic instrument designed for the installation, testing, and maintenance of refrigeration equipment such as air conditioners, refrigerators, and cold storage units. It offers multiple test modes, intelligent digital display, and a built-in refrigerant database for efficient operation, making it a versatile tool for professionals.

AUTOOL LM 120 Digital Manifold Gauge Meter with hoses and clamps

Figure 1: AUTOOL LM 120 Digital Manifold Gauge Meter and accessories.

2. Ntuziaka Nhazi

Follow these steps to properly set up your AUTOOL LM 120 Digital Manifold Gauge Meter:

  1. Steeti izizi: Before operation, ensure both the low pressure (blue) and high pressure (red) valves on the manifold gauge are in the closed position.
  2. Connect Temperature Clamps: Connect the two temperature-test clamps to their respective sockets on the manifold gauge. These clamps are essential for accurate temperature readings during testing.
    Connecting temperature clamps to the manifold gauge

    Figure 2: Connecting the temperature clamps for high and low pressure temperature testing.

  3. Ike Na: Press the power switch on the manifold gauge to turn on the device. The LCD display will illuminate, showing current readings and settings.
  4. Connect Tubes: Connect the blue, yellow, and red tubes to the corresponding ports on the manifold gauge. Ensure connections are secure to prevent leaks.
  5. Connect Refrigerant Quick Connectors: Attach the refrigerant quick connectors to the appropriate service ports on the refrigeration system (e.g., vehicle AC system). The red connector typically goes to the high-pressure port, and the blue to the low-pressure port.

Video 1: Demonstrates the setup and connection process for the AUTOOL LM 120 Digital Manifold Gauge Meter, including connecting temperature clamps and refrigerant tubes to a vehicle's AC system.

3. Ntuziaka ọrụ

The AUTOOL LM 120 offers various functions for comprehensive refrigeration system analysis:

3.1. Ọrụ Vacuum

To perform a vacuum operation, ensure all connections are secure. Open the necessary valves on the manifold gauge to initiate the vacuum process. The gauge will display the vacuum degree, allowing you to monitor the system's evacuation.

3.2. Refrigerant Filling

  1. Connect Refrigerant Container: After vacuuming, connect a new refrigerant container to the yellow service hose of the manifold gauge.
  2. Prepare Vehicle (if applicable): If working on a vehicle, start the engine and adjust the air conditioner to its lowest temperature setting to ensure the system is ready for refrigerant intake.
  3. Inlet Refrigerant: Slowly open the appropriate valves on the manifold gauge to allow the new refrigerant to enter the system. Monitor the pressure readings on the digital display to ensure proper filling.

3.3. Multiple Test Modes

The LM 120 supports various test modes:

  • Dual Pressure Measurement: Measures both high and low pressures simultaneously.
  • Dual Temperature Measurement: Measures high and low pipeline temperatures using the connected test clamps.
  • Vacuum Degree Measurement: Na-egosiputa pasentịtage of vacuum achieved.
  • Pressure Leakage Measurement: Calculates pressure difference over time to detect leaks.
  • Ngbanwe nke otu: Easily switch between pressure units (Kpa, Mpa, bar, inHg, PSI) and temperature units (Celsius/Fahrenheit).
Evaporation Pressure and Temperature Test on AUTOOL LM 120

Figure 3: Display showing Evaporation Pressure & Temperature Test results.

Condensing Pressure and Temperature Test on AUTOOL LM 120

Figure 4: Display showing Condensing Pressure & Temperature Test results.

Pressure Leakage Test on AUTOOL LM 120

Figure 5: Display showing Pressure Leakage Test results.

3.4. Built-in Database

The LM 120 features a built-in database of 89 kinds of refrigerant pressure and evaporation temperatures. This allows the device to automatically calculate supercooling and superheating temperatures, providing convenient and direct access to critical operational data.

Refrigerant Type Setting and Observation Window on AUTOOL LM 120

Figure 6: Setting refrigerant type and observing filling status through the viewable window.

4. Nlekọta

Proper maintenance ensures the longevity and accuracy of your AUTOOL LM 120 Digital Manifold Gauge Meter:

  • Nhicha: Regularly wipe the device with a soft, dry cloth. Avoid using abrasive cleaners or solvents that could damage the display or casing.
  • Nchekwa: After each use, carefully uninstall all quick connectors and tubes. Turn off the manifold gauge. Pack the equipment securely in its carrying case to protect it from dust, moisture, and physical damage.
  • Nyocha akụkụ: Periodically inspect the hoses, connectors, and temperature clamps for any signs of wear, cracks, or damage. Replace any worn components to maintain optimal performance and prevent refrigerant leaks.
  • Ogologo oge: The LM 120 is constructed with high-strength engineering plastic, flexible non-slip silicone, and copper interfaces, designed for industrial-grade durability. Proper handling and storage will further extend its service life.

5. Nchọpụta nsogbu

If you encounter issues with your AUTOOL LM 120, consider the following:

  • Ọgụgụ na-ezighi ezi: Ensure all connections are tight and free of leaks. Verify that the correct refrigerant type is selected in the device settings. If persistent, contact customer support for potential calibration needs.
  • Temperature Sensor Issues: Check the connection of the temperature clamps. Ensure they are securely attached to the pipes for accurate readings. If clamps are damaged, they may need replacement.
  • Enweghị Ngosipụta/Ike: Check battery levels. Ensure the power button is pressed firmly.
  • Hose Leaks: Inspect hoses and their connections for any visible damage or loose fittings. Tighten connections or replace hoses if necessary.
  • Ọrụ Vacuum: Note that the LM 120 measures relative vacuum degree and does not display micron readings. If micron-level vacuum measurement is required, a different model may be necessary.

For issues not covered here, please refer to the detailed product manual or contact AUTOOL customer support.

6. Nkọwapụta

OkeUru
Nọmba Nlereanya iheLM 120
Onye nrụpụtaỤgbọala
Ihe onwunweCrystal, Silicone
Akụkụ akụkụ L x W x H0.01 sentimita asatọ
Ibu Ibu950 grams
Nha ihuenyo12 sentimita asatọ
Pressure Test TypeNrụgide ihu
Pressure Test UnitsKpa; Mpa; bar; inHg; PSI
Oke ule nrụgide0 Kpa - 6000 Kpa
Mkpebi ule nrụgide1 Kpa
Nnwale nrụgide ziri ezi+/- 0.5%(FS)+ 5dgt
Oke ibufe nrụgide10000 Kpa (10 Mpa; 100 bar;)
Vacuum Test TypeRelative vacuum
Vacuum Test UnitsKpa; Mpa; bar; inHg; PSI
Oke ule oghere-101 Kpa ~ 0 Kpa
Mkpebi ule Vacuum1 Kpa
Temperature Test Units°C (Celsius), °F (Fahrenheit)
Oke ule okpomọkụ-40°C ~ 150°C (-40°F ~ 302°F)
Mkpebi ule okpomọkụ0.1°C (-40°C ~ 99.9°C), 1°C (100°C ~ 150°C), 0.1°F (-40°F ~ 99.9°F), 1°F (100°F ~ 302°F)
Nnwale okpomoku ziri ezi+/- 0.5°C + 2dgt, +/- 0.9°F + 2dgt
Technical Parameters table for AUTOOL LM 120

Figure 7: Detailed technical parameters of the AUTOOL LM 120.

7. Akwụkwọ ikike na nkwado

AUTOOL stands behind the quality of its products:

  • Akwụkwọ ikike nke afọ atọ: For damage caused by non-human factors, AUTOOL promises to resend parts for free within 3 years.
  • Lifelong Maintenance: The product is supported with lifelong maintenance.
  • Nkwado ndị ahịa: For any inquiries or support needs, AUTOOL offers 24/7 customer support. You can contact them for assistance with product operation, troubleshooting, or warranty claims.
24/7 Customer Support iconAkara ikike afọ 3

Figure 8: AUTOOL's commitment to customer support and warranty.

Akwụkwọ ndị emetụtara - LM 120

Tupuview AUTOOL Im 120 Digital Manifold Gauge User Manual
Comprehensive user manual for the AUTOOL Im 120 Digital Manifold Gauge, detailing its features, specifications, operation instructions for refrigerant filling, vacuum testing, leak detection, safety precautions, common problems, and a glossary of terms relevant to refrigeration systems.
Tupuview AUTOOL LM120/LM120+ Digital Manifold Gauge User Manual
This user manual provides comprehensive guidance for the AUTOOL LM120/LM120+ Digital Manifold Gauge. It details product specifications, structure, function instructions for refrigerant filling, vacuum operation, and pressure leak testing. The manual also includes common problems, a glossary of terms, maintenance advice, warranty information, and return/exchange procedures. Essential for HVAC technicians and refrigeration professionals.
Tupuview AUTOOL LM150 Digital Manifold Pressure Tester User Manual - HVAC Refrigerant Tool
Comprehensive user manual for the AUTOOL LM150 Digital Manifold Pressure Tester. Covers product specifications, operating instructions for refrigerant filling, vacuum, and leak testing, common problems, glossary of terms, maintenance, warranty, and return policy for HVAC and refrigeration professionals.
Tupuview Akwụkwọ ntuziaka AUTOOL LM120+ Digital Manifold Gauge
Comprehensive user manual for the AUTOOL LM120+ Digital Manifold Gauge, detailing its features, specifications, safety precautions, operating instructions, and troubleshooting tips for refrigeration and HVAC systems.
Tupuview Akwụkwọ ntuziaka AUTOOL LM160 Smart Digital Manifold Kit
Comprehensive user manual for the AUTOOL LM160 Smart Digital Manifold Kit, covering operation, technical specifications, maintenance, and safety for HVAC applications.
Tupuview Akwụkwọ ntuziaka onye ọrụ AUTOOL LM150 Digital Manifold Pressure Test
User manual for the AUTOOL LM150 Digital Manifold Pressure Tester, providing detailed instructions, specifications, safety guidelines, and troubleshooting for HVAC and refrigeration system testing.