Acrel DTSD1352

Akwụkwọ ntuziaka onye ọrụ Acrel DTSD1352 maka mita ike nke usoro atọ

Model: DTSD1352 | Brand: Acrel (Manufactured by TGLGTQPX)

1. Okwu mmalite

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Acrel DTSD1352 Three Phase Bidirectional Energy Meter. This device is designed for accurate measurement of three-phase energy consumption and generation, featuring RS485 communication for integration into monitoring systems. Please read this manual thoroughly before installation and operation to ensure safe and efficient use.

2. Ozi nchekwa

ỊDỌ AKA NA NTỊ: Ihe ize ndụ nke mkpọ ọkụ eletrik!

  • Ekwesịrị ịrụ nrụnye na nrụzi naanị site n'aka ndị ọrụ ọkụ eletrik ruru eru.
  • Ensure all power is disconnected before installing or servicing the meter.
  • Do not touch live terminals.
  • Verify correct wiring connections to prevent damage to the meter or electrical system.
  • The meter must be installed in a dry, well-ventilated area, free from excessive dust, corrosive gases, and direct sunlight.

3. Ngwaahịa gafereview

The Acrel DTSD1352 is a compact and robust three-phase multi-function energy meter. It features a clear LCD display for real-time data, intuitive control buttons, and various connection terminals.

N'ihu view of the Acrel DTSD1352 energy meter showing the LCD display, control buttons, and terminal connections.

Foto 3.1: N'ihu view of the DTSD1352 meter. This image displays the main LCD screen showing power readings (e.g., 0.00 kW), the "SET" button, and three orange arrow buttons for navigation. Terminal blocks are visible at the top and bottom for electrical connections.

N'akuku view of the Acrel DTSD1352 energy meter, showing the side profile and additional terminal details.

Foto 3.2: N'akuku view of the DTSD1352 meter. This perspective highlights the compact design and the various input/output terminals on the top and bottom, as well as the side labeling for model identification.

4. Nkọwapụta

The following table outlines the key technical specifications of the Acrel DTSD1352 energy meter. For detailed information, refer to the product datasheet.

Table of technical specifications for the Acrel DTSD1352 energy meter, including voltage, current, measurement performance, pulse, communication, outline, and environment details.

Foto 4.1: Detailed technical specifications. This image presents a table covering various parameters such as reference voltage (3*57.7/100V, 3*220/380V, 3*380V), reference frequency (50Hz), maximum current (6A, 80A), accuracy (Class 0.5S), communication interface (RS485, MODBUS-RTU), dimensions (127*88*70 mm), and environmental conditions (operating temperature -25~55℃, humidity ≤95%).

Tebụl 4.1: Nkọwa n'ozuzu
OkeUru
Ntụaka Voltage3*57.7/100V, 3*220/380V, 3*380V
Ugboro ntụaka50Hz
Kachasị ugbu a6A, 80A (depending on model)
Accuracy of active kWhKlas 0.5S
Interface nkwurịta okwuRS485
Protocol nzikọrịta oziMODBUS-RTU
Akụkụ (L*W*H)127mm * 88mm * 70mm
Okpomọkụ na-arụ ọrụ-25 ℃ ruo 55 ℃
Okpomọkụ nchekwa-40 ℃ ruo 70 ℃
iru mmiri≤95% (enweghị condensation)
Elu<2000m
Ibu Ibu7.1 ounces (ihe dị ka 200g)

5. Nwụnye na Wiring

Proper installation and wiring are critical for the accurate and safe operation of the DTSD1352 meter. Refer to the diagrams below for connection methods.

Wiring diagrams for the Acrel DTSD1352 energy meter, showing both direct connection (3P4W) and connection via Current Transformers (CTs).

Foto 5.1: Wiring diagrams. This image illustrates two primary wiring methods: a 3-phase 4-wire (3P4W) direct connection where power lines (A, B, C, N) connect directly to the meter, and a connection via Current Transformers (CTs) for higher current applications, showing the CTs connected to the respective phase lines and then to the meter.

5.1 Direct Connection (3P4W)

For direct connection, ensure the phase lines (A, B, C) and neutral (N) are connected to the corresponding terminals on the meter. This method is typically used for lower current applications where the meter can directly handle the load current.

  • Connect Phase A to terminal 'A'.
  • Connect Phase B to terminal 'B'.
  • Connect Phase C to terminal 'C'.
  • Connect Neutral to terminal 'N'.
  • Gbaa mbọ hụ na njikọ niile echekwara na mkpuchi nke ọma.

5.2 Connection via Current Transformers (CTs)

For higher current applications, the DTSD1352 meter can be connected via external Current Transformers (CTs). This method scales down the current to a measurable level for the meter.

  • Install the CTs on each phase line (A, B, C).
  • Connect the secondary windings of the CTs to the corresponding current input terminals (e.g., Ia*, Ia, Ib*, Ib, Ic*, Ic) on the meter.
  • Ensure the polarity of the CTs is correct (P1/K to the source side, P2/L to the load side, and S1/S2 to the meter). Incorrect polarity will result in inaccurate readings.
  • Jikọọ voltage inputs (Ua, Ub, Uc, N) directly from the respective phases and neutral to the meter.
  • It is recommended to install a fuse on the voltage input lines for protection.

Important: Always ensure the CT secondary circuit is closed before applying power to the primary circuit. Never open the secondary circuit of a live CT.

6. Ọrụ

Once installed and powered, the DTSD1352 meter will automatically begin measuring. The LCD display shows various parameters, which can be navigated using the control buttons.

6.1 Ngosipụta igodo

  • Ngosipụta LCD: Shows real-time measurements such as voltage, current, active power, reactive power, power factor, frequency, and total energy (kWh).
  • "SET" Button: Used to enter the parameter setting mode or confirm selections.
  • Arrow Buttons (Left, Right, Up, Down): Used to navigate through different display screens or adjust parameter values in setting mode.

6.2 Reading Energy Data

Press the arrow buttons to cycle through the various measurement screens. Common readings include:

  • Total Active Energy (kWh)
  • Forward Active Energy (kWh)
  • Reverse Active Energy (kWh)
  • Voltage (V) per phase
  • Current (A) per phase
  • Active Power (kW) per phase and total
  • Reactive Power (kVar) per phase and total
  • Ihe na -eme ike (PF)
  • Ugboro (Hz)

6.3 RS485 Nkwukọrịta

The meter supports RS485 communication with MODBUS-RTU protocol. This allows for remote reading of meter data and configuration. Refer to the MODBUS communication protocol document for detailed register addresses and commands.

7. Nlekọta

The DTSD1352 energy meter is designed for long-term, reliable operation with minimal maintenance. However, periodic checks are recommended.

  • Nhicha: Keep the meter clean and free from dust. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents.
  • Njikọ: Periodically check all wiring connections to ensure they are tight and secure. Loose connections can lead to inaccurate readings or overheating.
  • gburugburu: Gbaa mbọ hụ na gburugburu ebe ọrụ ka dị n'ime oke okpomọkụ na iru mmiri akọwapụtara.
  • Nhazi The meter is factory calibrated. If you suspect inaccuracies, contact qualified service personnel for recalibration.

8. Nchọpụta nsogbu

This section provides solutions to common issues you might encounter with the DTSD1352 meter.

Isiokwu 8.1: Ntuziaka nchọpụta nsogbu
NsogbuIhe nwere ike imeNgwọta
Meter display is blank.No power supply to the meter.Check the main power supply and wiring connections to the meter's voltage input terminals. Ensure fuses are intact.
Inaccurate energy readings.Incorrect wiring, incorrect CT ratio setting (if applicable), faulty CTs, or meter malfunction.Verify all wiring connections according to Section 5. Ensure CT polarity is correct. Check if the CT ratio programmed in the meter matches the physical CTs. If issues persist, contact technical support.
ọdịda nkwurịta okwu RS485.Incorrect wiring of RS485 terminals (A/B), incorrect communication parameters (baud rate, parity, address), or software issue.Check RS485 A and B terminal connections. Verify communication settings (baud rate, data bits, stop bits, parity, meter address) in your master device match the meter's settings. Ensure proper termination resistors are used if necessary.
Meter shows "Error" or specific error codes.Internal fault or specific operational issue.Note down the error code and consult the full product manual or contact technical support for specific error code interpretations and solutions.

9. Akwụkwọ ikike na nkwado

This product is manufactured by TGLGTQPX and sold under the Acrel brand. For specific warranty terms and conditions, please refer to the documentation provided at the time of purchase or contact your vendor. General support for the Acrel DTSD1352 meter can be obtained through the manufacturer's official channels or your authorized distributor.

For technical assistance, troubleshooting beyond this manual, or spare parts, please contact:

  • Onye nrụpụta: TGLGTQPX
  • Akara ngwaahịa: Acrel
  • Ụdị: DTSD1352
  • (Contact information such as website or email would typically be provided here by the manufacturer.)

Akwụkwọ ndị emetụtara - DTSD1352

Tupuview Ntuziaka maka ntinye na ọrụ mita eletriki nke otu usoro ADL100-ET
Ntuziaka zuru oke maka ntinye na ọrụ nke mita eletriki Acrel ADL100-ET nke otu-phase. Akwụkwọ ntuziaka a na-akọwa nkọwapụta teknụzụ, nkọwa ọrụ, ntuziaka waya, menu ngosipụta, usoro mmemme, na usoro nkwukọrịta (Modbus RTU).
Tupuview Acrel D318 Harmonic Meter Operation Instruction Manual
Operation instruction manual for the Acrel D318 External Roche Coil and Switched Transformer Harmonic Meter. Details features, technical specifications, and connection methods for energy saving and power monitoring applications.
Tupuview Acrel ADL3000-E Smart Mita: Akwụkwọ ntuziaka maka ntinye na ọrụ
Ntuziaka zuru oke maka ntinye na ọrụ mita Acrel ADL3000-E, nke gụnyere nkọwapụta teknụzụ, waya, ọrụ ngosipụta, na usoro nkwukọrịta.
Tupuview DJSF1352-RN Rail-Mounted DC Power Meter Installation and Operation Manual
This document provides comprehensive installation and operation instructions for the Acrel DJSF1352-RN rail-mounted DC power meter. It covers product specifications, technical parameters, wiring diagrams, operational guidance, menu settings, and communication protocols (Modbus-RTU, DLT645-07).
Tupuview Ngwa eletriki dị iche iche nke ụdị Acrel ACR10R nke nwere Transformer Mpụga nke Split Core - Ntuziaka Ojiji na Nwụnye
This manual provides comprehensive instructions for the Acrel ACR10R series rail-type multifunction electrical instrument, including its specifications, functions, installation, programming, and RS485 MODBUS-RTU communication. It details technical parameters, connection modes, operation procedures, and troubleshooting guidance for industrial and commercial power monitoring applications.
Tupuview ATE 系列无线测温传感器安装说明 V1.7
本说明书详细介绍了 ATE系列无线测温传感器的产品概述、型号说明、技术指标、安装方法以及,怳法以及,湨睡湳以及。 3-35kV 户内开关柜和 0.4kV 低压柜.