1. Okwu mmalite
This manual provides essential information for the safe installation, operation, and maintenance of your Anern 1500W Hybrid Solar Inverter. This device integrates the functions of a solar inverter, MPPT solar charger, and battery charger to provide uninterrupted power support. It is designed for both on-grid and off-grid applications, supporting various battery types including lithium, lead-acid, and gel batteries.
Please read this manual thoroughly before installation and use to ensure optimal performance and safety.
2. Ntuziaka nchekwa
Adherence to these safety guidelines is crucial to prevent injury and damage to the inverter or connected equipment.
- Ndị ọrụ ruru eru ga-arụrịrị nrụnye.
- Ensure all wiring is correctly polarized and securely connected.
- Do not disassemble the inverter; refer servicing to authorized personnel.
- Avoid exposing the inverter to rain, snow, or liquids.
- Hụ na ikuku dị mma gburugburu inverter iji gbochie oke okpomọkụ.
- Always disconnect power before performing any maintenance or wiring.
- Use appropriate circuit breakers and fuses as specified in the electrical diagrams.
3. Ngwaahịa gafereview
The Anern 1500W Hybrid Solar Inverter is a multi-functional device designed for efficient power management in solar energy systems. It features a pure sine wave output, ensuring compatibility with sensitive electronics.

Foto 3.1: N'ihu view of the Anern 1500W Hybrid Solar Inverter, showing the LCD display and control buttons.

Nyocha 3.2: N'eluview of the Anern 1500W Hybrid Solar Inverter highlighting nominal power, input voltage, na batrị voltage.

Foto nke 3.3: Ngwaahịa zuru ezu dị n'eluview illustrating the various components and their functions.
Akụkụ ndị bụ isi:
- Mpụta Sine Wave dị ọcha: Provides high-quality AC power suitable for all types of loads, including sensitive electronics.
- Integrated MPPT Charge Controller: Built-in 40A MPPT solar charge controller maximizes solar power harvesting.
- Ụdị chaja ọtụtụ: Supports "Only Solar", "Mains First", "Solar First", and "Mains & Solar hybrid" charging modes.
- Flexible Output Modes: Offers "Solar First" and "SBU Priority" output modes for diverse application requirements.
- Ndakọrịta batrị: Compatible with 24V lithium, lead-acid, and gel batteries.
- Ngosipụta LCD: Provides dynamic display of system data and operating status, with configurable settings.
- Battery-Independent Operation: Capable of operating without a battery in certain configurations.
4. Nka na ụzụ nkọwa
Below are the key technical specifications for the Anern 1500W Hybrid Solar Inverter (Model: Anern_1500W_24V).
| Njirimara | Nkọwapụta |
|---|---|
| Nlereanya | Anern_1500W_24V |
| Ike aha | 1500W |
| Ike ịwa ahụ | 2000W |
| Mmepụta Voltage | 230VAC |
| Ugboro mmepụta | 50/60Hz (Nchọpụta akpaaka) |
| Batrị Voltage | 24VDC |
| Oke. Ike ntinye PV | 1100W |
| PV Voltage Oke | 20-150VDC |
| Max. PV Input VOC | 150VDC |
| Malite Voltage | > 30VDC |
| Onye njikwa chaja MPPT | 40A |
| Recommended PV Cable Size | 12AWG |
| Max. Charge Current (AC + Solar) | 40A |
| Ịrụ ọrụ | Ruo 98% |
| Ogo nchekwa | IP21 |
5. Nwụnye
Proper installation is critical for the safe and efficient operation of your hybrid solar inverter. Ensure all local electrical codes and regulations are followed.
5.1 Nhọrọ saịtị
- Install the inverter indoors, away from direct sunlight, heat sources, and moisture.
- Ensure the mounting surface is strong enough to support the inverter's weight.
- Allow at least 20 cm (8 inches) of clearance around the inverter for proper airflow.
- Avoid areas with flammable materials or corrosive gases.
5.2 eserese waya
The following diagram illustrates a typical system connection for the hybrid solar inverter, including solar panels, batteries, and AC loads.

Figure 5.1: System diagram showing connections for solar panels, generator/utility, external battery packs, and household appliances.
- Njikọ batrị: Connect the battery bank to the inverter's battery terminals. Ensure correct polarity.
- PV Array Connection: Connect the solar panel array to the PV input terminals. Observe voltage na oke ugbu a.
- Njikọ ntinye AC: Connect the AC utility grid or generator to the AC input terminals.
- Njikọ Mbupụ AC: Connect your household loads to the AC output terminals.
- Nda ala: Ensure the inverter is properly grounded according to local electrical codes.
6. Ụdị ọrụ na ntọala
The inverter offers various configurable settings via its LCD display and control buttons. These settings allow you to optimize the system's performance based on your specific needs.
6.1 Ụdị Nchaji
- Naanị anyanwụ: Na-ebute ike anyanwụ ụzọ maka ịchaji batrị.
- Isi ihe mbụ: Prioritizes utility grid power for battery charging, using solar only when grid is unavailable.
- Anyanwụ Mbụ: Prioritizes solar power for battery charging, supplementing with grid power if solar is insufficient.
- Mains & Solar Hybrid: Utilizes both mains and solar power for charging, optimizing based on availability and load.
Ụdị mmepụta 6.2
- Anyanwụ Mbụ: Prioritizes solar power to supply loads, then battery, then utility grid.
- SBU Priority: Prioritizes Solar, then Battery, then Utility grid for supplying loads.
6.3 LCD Display and Control
The LCD display provides real-time system data, including input/output voltage, battery status, and load levels. Use the function buttons to navigate menus and configure settings such as battery charging current, AC/solar charger priority, and load supply priority.

Figure 6.1: Close-up of the LCD display showing system status and indicators.
7. Nlekọta
Mmezi mgbe niile na-eme ka ogologo ndụ na arụmọrụ kachasị mma nke inverter gị.
- Nhicha: Keep the inverter's exterior clean and free of dust. Use a dry cloth. Do not use liquid cleaners.
- Igwe ikuku: Ensure ventilation openings are clear and not obstructed.
- Njikọ: Na-elele njikọ eletriki niile mgbe niile maka ike na ihe ịrịba ama nke ire ere.
- Nyocha batrị: Ọ bụrụ na ị na-eji batrị lead-acid, lelee ọkwa electrolyte na ọnọdụ njedebe dịka ntuziaka ndị nrụpụta batrị si dị.
- Nyocha gburugburu: Gbaa mbọ hụ na gburugburu ebe arụ ọrụ ka dị n'ime oke okpomọkụ na iru mmiri akọwapụtara.
8. Nchọpụta nsogbu
This section provides solutions to common issues you might encounter. For problems not listed here, contact technical support.
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Inverter anaghị agbanyụ | No battery connection; Battery voltage too low; Power switch off. | Lelee njikọ batrị na voltage; Ensure power switch is on. |
| Enweghị mmepụta AC | Overload; Short circuit; Inverter fault; Battery low. | Reduce load; Check for short circuits; Check battery voltage; Restart inverter. |
| Nchaji anyanwụ anaghị arụ ọrụ | Ntinye PV voltage too low/high; PV array disconnected; MPPT controller fault. | Check PV connections and voltage; Ensure sufficient sunlight; Consult manual for error codes. |
| Mkpọtụ na-adịghị mma | Loose components; Fan obstruction; Internal fault. | Inspect for loose parts; Clear fan obstructions; If persistent, contact support. |
9. Akwụkwọ ikike na nkwado
Anern provides a standard warranty for this product. Please refer to the warranty card included with your purchase for specific terms and conditions. For technical support, service, or warranty claims, please contact Anern customer service through their official channels or visit their websaịtị.
Onye nrụpụta: Anern
Ụbọchị mbụ dị: Maachị 3, 2025
Ị nwere ike ịchọta ozi na nkwado na Anern Store on Amazon.