OONO D-1410

ONO 16 Amp 2x12 Position Terminal Block Distribution Module D-1410 User Manual

Ụdị: D-1410

1. Okwu mmalite

This manual provides essential information for the safe and efficient use of the OONO 16 Amp 2x12 Position Terminal Block Distribution Module, Model D-1410. Please read this manual thoroughly before installation and operation to ensure proper functionality and safety.

2. Ozi nchekwa

Ịdọ aka ná ntị: Electrical work should only be performed by qualified personnel. Failure to follow these safety guidelines may result in electric shock, fire, or personal injury.

  • Always disconnect power before installing, wiring, or servicing the module.
  • Ensure all connections are secure to prevent loose wires and potential short circuits.
  • Agafela voltage (48V) or current (16 Amp) of the module.
  • Use appropriate wire gauges (26AWG ~ 12AWG) for connections.
  • Mount the module in a dry, protected environment, away from moisture and extreme temperatures.

3. Ngwaahịa gafereview

The OONO D-1410 is a 16 Amp, 48V, 2x12 position screw terminal block distribution module designed for AC/DC applications. It facilitates organized and efficient power distribution by allowing multiple connections from a single source. The module supports multiple module extension connections for larger systems.

3.1 Akụkụ

  • Mgbochi ọnụ: Two rows of 12 screw terminals each (A1-A12, B1-B12) for connecting wires.
  • Ọnụ ntinye/mmepụta: Larger A and B terminals for main power input/output.
  • PCB: FR-4 glass fiber printed circuit board.
  • Oghere mgbakwasị: For securing the module.
OONO D-1410 Terminal Block Distribution Module

Figure 1: OONO D-1410 Terminal Block Distribution Module. This image shows the overall view of the green terminal block module with its two rows of screw terminals and main A/B input/output points.

OONO D-1410 Terminal Block with A/B Inputs

Figure 2: OONO D-1410 Terminal Block with A/B Inputs. A closer view highlighting the main A and B input/output terminals on the left side of the module.

OONO D-1410 Terminal Block Top View

Figure 3: OONO D-1410 Terminal Block Top View. This image provides an overhead perspective of the module, clearly showing all 24 screw terminals arranged in two parallel rows.

OONO D-1410 Terminal Block Bottom View

Figure 4: OONO D-1410 Terminal Block Bottom View. This image displays the underside of the PCB, showing the solder points and the model version "D-1410 Ver. 1.0".

4. Nkọwapụta

NjirimaraNkọwapụta
Nọmba nlereanyaD-1410
Enyere aha ugbu a16 Amp (total input or output)
Oke Voltage48V
Ọnụọgụ nke ọkwa2x12 (24 total contacts)
Terminal Block Pitch (A/B)7.5mm / 0.295"
Terminal Block Pitch (A1-B12)5.0mm / 0.197"
Oke waya26AWG ~ 12AWG / 2.5mm²
Ogologo eriri7mm
kposaraM3, steel, Cr3+ Zn plated
Pin Header and CageBras
PCB iheFR-4 glass fiber
AsambodoUL, CE, CQC
Akụkụ ngwaahịa4.72"W x 0.97"H (approx. 120mm x 24.6mm)
OONO D-1410 Terminal Block Dimensions Diagram

Figure 5: OONO D-1410 Terminal Block Dimensions. This diagram illustrates the physical dimensions of the module in millimeters, including screw and spacer details.

5. Ntọala na nwụnye

Follow these steps for proper installation of the OONO D-1410 module:

  1. Ịkwụsị ike: Ensure all power sources to the circuit are disconnected before beginning installation. Verify with a voltagọ bụ onye nyocha.
  2. Ịkwanye:
    • Identify a suitable, dry, and stable mounting surface.
    • Use the provided screws and nylon spacers to secure the module. The spacers help insulate the underside of the PCB from the mounting surface.
    • Ensure the module is firmly attached to prevent movement or strain on connections.
  3. Wiring the Main Power:
    • Connect the main power input wires to the larger 'A' and 'B' terminals on the module.
    • Strip approximately 7mm of insulation from the wire ends.
    • Insert the stripped wire into the terminal opening and tighten the M3 screw securely. Ensure no stray wire strands are exposed.
  4. Wiring Output Devices:
    • Connect the wires from your output devices (loads) to the individual A1-A12 and B1-B12 terminals.
    • Each 'A' terminal (A1, A2, etc.) is connected to the main 'A' input, and each 'B' terminal (B1, B2, etc.) is connected to the main 'B' input.
    • Maintain proper polarity for DC circuits.
    • Ensure wires are within the 26AWG ~ 12AWG range.
    • Mee ka skru niile dị n'akụkụ sie ike.
  5. Nyocha: Double-check all wiring for correctness, secure connections, and absence of short circuits before restoring power.
OONO D-1410 Typical Connection Diagram

Figure 6: Typical Connection Use Method. This diagram illustrates how multiple OONO D-1410 modules can be interconnected to distribute power to various loads from a single source. It shows the main A and B lines feeding into the modules, which then distribute to individual loads.

OONO D-1410 Schematic Diagram

Figure 7: OONO D-1410 Schematic. This schematic diagram shows the internal wiring of the terminal block, indicating that all 'A' terminals are common and all 'B' terminals are common, allowing for parallel distribution.

6. Ntuziaka ọrụ

Once the OONO D-1410 module is correctly installed and wired, operation is straightforward:

  • Ike Na: After verifying all connections, restore power to the circuit.
  • Nkesa ike: The module will distribute the input power from the main 'A' and 'B' terminals to all corresponding individual 'A' and 'B' output terminals.
  • Load Operation: Connected devices will receive power according to their wiring.
  • Nleba anya: Periodically check connections for any signs of overheating or loose wires, especially during initial operation.

7. Nlekọta

The OONO D-1410 module requires minimal maintenance. Regular inspections are recommended to ensure continued safe and reliable operation.

  • Nlele anya: Periodically inspect the module and all connections for any signs of damage, corrosion, or loose wires.
  • Nhicha: If necessary, gently clean the module with a dry, soft cloth. Do not use liquids or abrasive cleaners. Ensure power is disconnected before cleaning.
  • Mechie njikọ: Over time, vibrations or temperature changes can cause screws to loosen. Periodically re-tighten all terminal screws, ensuring not to overtighten.

8. Nchọpụta nsogbu

If you encounter issues with your OONO D-1410 module, consider the following troubleshooting steps:

NsogbuIhe nwere ike imeNgwọta
Enweghị ike na ngwaọrụ ejikọrọ.
  • Ọkụ ọkụ isi agbanyụrụ.
  • Loose connection at main A/B terminals.
  • Loose connection at individual output terminals.
  • Wiring na -ezighi ezi.
  • Check and restore main power.
  • Disconnect power, then check and tighten main A/B connections.
  • Disconnect power, then check and tighten individual output connections.
  • Disconnect power, review wiring diagram (Figure 6, Figure 7) and correct connections.
Module or wires are overheating.
  • Overcurrent (exceeding 16 Amp ngụkọta).
  • Loose connections causing resistance.
  • Incorrect wire gauge for the load.
  • Immediately disconnect power. Reduce the total load or use multiple modules.
  • Disconnect power, check and tighten all connections.
  • Ensure wire gauge is appropriate for the current draw (26AWG ~ 12AWG).
Intermittent power to devices.
  • Njikọ waya rụrụ arụ.
  • Damaged wire insulation.
  • Disconnect power, check and re-tighten all connections.
  • Disconnect power, inspect wires for damage and replace if necessary.

9. Akwụkwọ ikike na nkwado

For warranty information or technical support regarding your OONO D-1410 Terminal Block Distribution Module, please contact OONO customer service through the retailer where the product was purchased or visit the official OONO websaịtị.

Onye nrụpụta: CZH-LABS

Ụbọchị mbụ dị: Maachị 13, 2018

Akwụkwọ ndị emetụtara - D-1410

Tupuview OONO F-1040 Akpaaka obere Voltage Kpupu modul: Njirimara, nkọwapụta na nwụnye
Ozi zuru ezu na OONO F-1040 Automatic Low Voltage Kwupu Modul, gụnyere atụmatụ ya, voltage, ọkwa dị ugbu a, ntuziaka nrụnye, na nkọwapụta maka ichedo batrị site na mwepu miri emi.
Tupuview OONO F-1021 Series 50 Amp Forward & Reverse Relay Module - Technical Specifications
Comprehensive technical specifications, features, wiring diagrams, and dimensions for the OONO F-1021 series 50 Amp Forward & Reverse Relay Module, designed for motor control applications requiring motion reversal.
Tupuview ONO 10 Amp Forward & Reverse Relay Module F-1020 Series: User Guide
Detailed guide for the OONO F-1020 series 10 Amp Forward & Reverse Relay Module, covering features, specifications, wiring diagrams, and dimensions for 5V, 12V, and 24V versions.
Tupuview OONO F-1081 Series 10 Amp Reversing Relay Module with Limit Switch Support
Technical datasheet for the OONO F-1081 series 10 Amp Reversing Relay Module, featuring support for limit switches and various switch types (momentary, alternate-action). Includes specifications and wiring diagrams for 5V, 12V, and 24V versions.
Tupuview ONO F-1030 Series DPST 1NO 1NC 8Amp Latching Relay Module | Technical Specifications
Detailed technical specifications, features, and wiring diagrams for the OONO F-1030 series DPST 1NO 1NC 8Amp Latching Relay Module. Covers input control modes, output switch capabilities, voltage versions, and dimensions.
Tupuview OONO F-1057 Electric Heating Relay User Manual
Instructions and specifications for the OONO F-1057 On/Off Switching Electric Heating Relay with Built-in 24V Transformer, designed for AC 120V resistive loads controlled by low voltagna thermostats.