1. Okwu mmalite
This manual provides essential information for the safe and efficient operation of your Anern 3600W Hybrid Solar Inverter. This all-in-one unit integrates a 3600W pure sine wave inverter, a 120A MPPT solar charge controller, and a battery charger. It is designed to convert 24V DC power to 110V/120V AC power, suitable for various home backup, RV, and off-grid applications. Please read this manual thoroughly before installation and use.

Figure 1: Anern 3600W Hybrid Solar Inverter (Model Anern-3600)
2. Ozi nchekwa
Observe the following safety precautions to prevent injury and damage to the inverter or connected equipment:
- Ndị ọrụ ruru eru ga-arụrịrị nrụnye.
- Gbaa mbọ hụ na wiwi niile dabara na koodu eletriki mpaghara na nke mba.
- Ekwula ihe na-agbanwe agbanwe. Enweghị akụkụ ọ bụla dị n'ime ya nke a ga-eji rụọ ọrụ.
- Disconnect all power sources (PV, battery, AC input) before performing any wiring or maintenance.
- Avoid contact with live terminals.
- Wụnye inverter ahụ n'ebe ikuku na-anaghị abata nke ọma, pụọ na ihe ndị na-ere ọkụ na mmiri.
- Gbaa mbọ hụ na ntọala nke inverter kwesịrị ekwesị.
- This inverter is equipped with multiple protection features including overcurrent, low-voltage, short-circuit, overheating, and overload protection.

Figure 2: Inverter Protection Features and Wi-Fi Monitoring Capability
3. Akụrụngwa Ngwaahịa
The Anern 3600W Hybrid Solar Inverter offers a range of features for reliable power management:
- Integrated System: Combines a 3600W pure sine wave inverter, 120A MPPT solar charge controller, and battery charger.
- Ịrụ ọrụ dị elu: Solar charge module utilizes optimized MPPT tracking technology for up to 98% efficiency.
- Ndakọrịta batrị: Supports 24V Lead-Acid (Sealed, AGM, Gel, Flooded) and Lithium batteries. Includes built-in lithium activation.
- Ọrụ na-enweghị batrị: Capable of powering loads directly from the PV array without a connected battery.
- Dual AC Output: Provides two AC outputs for flexible load management.
- Ngosipụta LCD: Features a responsive RGB LCD screen and indicator LEDs for real-time monitoring and configuration.
- Ụdị arụ ọrụ ọtụtụ: Offers 4 charging modes and 2 output modes to suit diverse application needs.
- Nchedo zuru oke: Includes protection against overvoltage, na -agbadatage, reverse polarity, short circuits, overheating, and overload.
- Nleba anya anya: Supports Wi-Fi monitoring for system control via a mobile application.

Figure 3: Key Specifications and Features Overview

Figure 4: Battery Compatibility and Battery-Free Operation
4. Ihe ngwugwu
Chọpụta na etinyere ihe niile na ngwugwu gị:
- Anern 3600W Hybrid Solar Inverter (Model Anern-3600)
- Akwụkwọ ntuziaka (akwụkwọ a)
- Mounting accessories (if applicable, check packaging)
- Communication cable (if applicable, for Wi-Fi module)
5. Nhazi ntuziaka
5.1. Mwepu na nyocha
Carefully unpack the inverter and inspect it for any shipping damage. If any damage is found, contact your supplier immediately.
5.2. Ịkwanye ihe ntụgharị
Select a suitable location for mounting the inverter. It should be:
- Indoors, protected from direct sunlight, rain, and dust.
- Well-ventilated to ensure adequate heat dissipation.
- Mounted vertically on a solid surface.
- Accessible for wiring and maintenance.
Use appropriate mounting hardware (not always included) to secure the inverter to the wall.
5.3. Njikọ njikọ
All wiring must be performed with all power sources disconnected. Refer to the wiring diagram (usually found on the inverter or in a detailed wiring section of the full manual) for specific terminal connections.
- Njikọ batrị: Connect the 24V battery bank to the inverter's battery terminals. Ensure correct polarity (+ to + and - to -). Use appropriately sized cables and fuses.
- PV Array Connection: Connect the solar panel array to the PV input terminals. Observe correct polarity and ensure the PV input voltage and current are within the inverter's specifications (Max PV Power 4200W, Max DC Voltagnke 500VDC).
- AC Input Connection (Grid/Generator): If connecting to a utility grid or generator, connect the AC input to the designated terminals.
- AC Output Connection (Loads): Connect your AC loads (appliances) to the inverter's AC output terminals. The inverter features dual AC outputs.
- Nda ala: Jikọọ ọdụ ụgbọ ala nke inverter ahụ na ala ala a pụrụ ịtụkwasị obi.
5.4. Ike mbido na nhazi
After all connections are secure and verified:
- Turn on the battery breaker/switch.
- Turn on the PV array breaker/switch.
- If applicable, turn on the AC input breaker.
- The inverter will power on and the LCD display will illuminate.
- Use the control buttons on the LCD panel to configure system settings such as charging current, voltage thresholds, and priority modes according to your requirements.

Figure 5: Dual AC Output and RGB LCD Display for Configuration
6. Ụdị arụ ọrụ
The inverter supports various charging and output modes to optimize power usage.
6.1. Ụdị Nchaji
You can select one of four charging modes:
- Naanị anyanwụ: The inverter charges the battery exclusively from solar energy.
- Mains Supply Priority: The inverter prioritizes charging from the utility grid (mains supply). Solar energy will supplement if available.
- Ihe kacha mkpa n'anwụ: The inverter prioritizes charging from solar energy. The utility grid will be used if solar power is insufficient.
- Mains Supply and Solar Charging Combination: The inverter uses both mains supply and solar energy to charge the battery simultaneously.
6.2. Output Modes
The inverter offers two output modes for continuous power supply:
- Power Bypass: In this mode, loads are powered directly from the AC input (utility grid or generator), bypassing the inverter. The inverter acts as a charger.
- Mmepụta ihe ntụgharị: Loads are powered by the inverter, drawing energy from the battery or directly from the PV array (if in battery-free mode).

Figure 6: Charging and Output Mode Diagram
7. Nlekọta
Mmezi oge niile na-eme ka arụmọrụ kachasị mma na ogologo ndụ nke inverter gị dịgide:
- Nhicha: Na-ehicha mpụta na oghere ikuku nke inverter mgbe ụfọdụ iji gbochie uzuzu ịgbasa, nke nwere ike igbochi oyi. Jiri ákwà kpọrọ nkụ ma dị nro.
- Lelee njikọ: Annually inspect all electrical connections for tightness and corrosion. Loose connections can cause overheating and poor performance.
- Nyocha gburugburu: Ensure the installation environment remains within specified temperature and humidity ranges.
- Nyocha batrị: If using lead-acid batteries, check electrolyte levels and terminal condition as per battery manufacturer guidelines.
- Mmelite femụwe: Lelee onye nrụpụta website for any available firmware updates for improved performance or new features.
8. Nchọpụta nsogbu
Nkebi a na-enye azịza maka nsogbu ndị a na-ahụkarị. Maka nsogbu ndị a na-edeghị ebe a, kpọtụrụ ndị na-ahụ maka teknụzụ.
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Inverter anaghị agba ọkụ | No battery connection; Battery voltage too low; Loose wiring; Blown fuse. | Lelee njikọ batrị na voltage; Ensure battery breaker is on; Inspect fuses. |
| Enweghị mmepụta AC | Overload; Short circuit; Inverter fault; AC output breaker tripped. | Reduce load; Check for short circuits in wiring; Reset AC output breaker; Restart inverter. |
| Battery not charging from PV | PV array disconnected; Insufficient sunlight; PV voltage too low/high; MPPT controller fault. | Check PV connections; Verify sunlight conditions; Ensure PV voltage is within range; Check MPPT settings. |
| Overload warning/shutdown | Connected load exceeds inverter capacity. | Belata ibu niile ejikọtara na inverter. |
| Ịdọ aka ná ntị okpomọkụ dị elu | Poor ventilation; Ambient temperature too high; Fan malfunction. | Ensure adequate airflow around the inverter; Relocate to a cooler area; Clean vents. |
9. Nkọwapụta
Detailed technical specifications for the Anern 3600W Hybrid Solar Inverter:
| Njirimara | Nkọwapụta |
|---|---|
| Nọmba nlereanya | Anern-3600 |
| Enyere ike | 3600W |
| Ike kacha elu | 7200W |
| Ntinye DC Voltage | 24VDC |
| Mmepụta AC Voltage | 110V/120VAC |
| Ugboro mmepụta AC | 50Hz/60Hz (Nchọpụta akpaaka) |
| Waveform | Okpokoro nke Sine |
| MPPT Charge Controller Current | 120A |
| Max PV Array ike | 4200W |
| Max PV DC Voltage | 500VDC |
| Ndakọrịta batrị | 24V Lead-Acid (Seal, AGM, Gel, Flooded), Lithium |
| Akụkụ ngwaahịa | 20.47 x 17.72 x 8.46 sentimita asatọ |
| Ibu Ibu | 22.2 pound |
10. Akwụkwọ ikike na nkwado