Okwu mmalite
The MedeScan Smart Talking Blood Pressure Monitor is designed to provide accurate and convenient blood pressure and pulse rate measurements for home use. This device incorporates Intelligent Averages Technology for enhanced precision and features a talking function for ease of use. Please read this manual thoroughly before using the device to ensure proper operation and safety.

Image: The MedeScan Smart Talking Blood Pressure Monitor with its digital display showing blood pressure and pulse readings, and control buttons.
Ozi nchekwa dị mkpa
- Gakwuru dọkịta gị tupu i jiri ngwaọrụ a ma ọ bụrụ na ị nwere nsogbu ahụike ọ bụla.
- Ejila ngwaọrụ a maka nyocha ma ọ bụ ọgwụgwọ nsogbu ahụike ma ọ bụ ọrịa ọ bụla.
- Debe ngwaọrụ ahụ ka ụmụaka ghara iru ya.
- Ejila ngwaọrụ ahụ n'ime ụgbọala na-agagharị agagharị.
- Avoid strong electromagnetic fields during use.
- Only use the specified cuff and accessories provided by MedeScan.
Ihe ngwugwu
Chọpụta na akụrụngwa niile dị na ngwugwu:
- 1 x Blood Pressure Monitor Device
- 1 x Adjustable Arm Cuff
- 1 x AC nkwụnye
- 1 x Akwụkwọ ntuziaka onye ọrụ
- 3 x AA batrị

Image: The MedeScan Blood Pressure Monitor, arm cuff, and power adapter laid out, showing the complete package contents.
Melite
- Isi mmalite ike: Insert 3 AA batteries into the battery compartment, ensuring correct polarity. Alternatively, connect the device to a power source using the provided AC adapter.
- User and Time Setting: Pịa SET button for 3 seconds to enter the setting mode. Choose User A or User B using the MEM button. Set the date and time using the MEM button to adjust values and SET iji gosi.
Ntuziaka ọrụ
Nkwadebe maka nha
- Zuru ike ma ọ dịkarịa ala nkeji 10 tupu ị tụọ nha.
- Avoid eating, smoking, or exercising immediately prior to measurement.
- Ensure you are in a quiet and relaxed environment.
Ndokwa Cuff
- Place the cuff on your bare upper arm, 2–3 cm (approximately 1 inch) above the elbow.
- Ensure the tubing runs inside your arm and is aligned with the center of your inner arm.
- The cuff should be snug but not too tight; you should be able to insert two fingers between the cuff and your arm.

Image: A person demonstrating the correct placement of the arm cuff on the upper arm, ensuring it is positioned properly for an accurate reading.
Na-ewere nha
- Sit comfortably with your feet flat on the floor and your arm level with your heart.
- Pịa Malite/Kwụsị button to begin the measurement.
- The cuff will automatically inflate and then slowly deflate. Remain still and silent during this process.
- Once the measurement is complete, your blood pressure (systolic and diastolic) and pulse rate will be displayed on the screen and announced by the talking function.

Image: A person seated, operating the MedeScan Blood Pressure Monitor to take a reading, with the cuff on their arm and their finger on the START/STOP button.
Viewing Past Readings (Memory Function)
- Pịa MEM button to scroll through stored results. The device stores up to 240 readings (120 per user).
- The Intelligent Averages Technology can calculate the average of multiple measurements for enhanced accuracy.
Nchọpụta Arrhythmia
- The monitor is equipped with Arrhythmia Monitoring, which alerts you to any irregular heartbeats detected during the measurement. If this icon appears frequently, consult your physician.
Mkpuchi akpaaka
- The device will automatically turn off after 60 seconds of inactivity to conserve power. You can also press Malite/Kwụsị iji aka gbanyụọ ya.
Nlekọta
- Nhicha: Wipe the device and cuff with a soft, dry cloth. Do not use abrasive cleaners or immerse the device in water.
- Nchekwa: Store the monitor and cuff in a cool, dry place, away from direct sunlight and extreme temperatures.
- Ngbanwe batrị: Dochie batrị mgbe ihe ngosi batrị dị ala pụtara na ngosipụta ahụ.
Nchọpụta nsogbu
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Ngwaọrụ anaghị agbanwu. | Batteries are low or incorrectly inserted; AC adapter not connected properly. | Check battery polarity, replace batteries, or ensure AC adapter is securely plugged in. |
| Ọgụgụ na-ezighi ezi. | Incorrect cuff placement; movement during measurement; not resting before measurement. | Ensure cuff is correctly placed, remain still and silent, rest for 10 minutes prior. |
| Cuff anaghị afụ ọnụ. | Air tube disconnected; cuff not properly wrapped. | Check that the air tube is securely connected to the monitor. Re-wrap the cuff snugly. |
Nkọwapụta
- Ụdị: BPS01
- Akụkụ ngwaahịa: 15.24 x 13.97 x 15.24 cm
- Ibu ihe: 482 grams
- Ike ebe nchekwa: 2 x 120 readings (240 total)
- Isi mmalite ike: 3 x AA Batteries or AC Adapter
- Ụdị ngosi: LCD
- Saịtị atụ: Ogwe aka elu
- Atụmatụ: Talking Function, Arrhythmia Detection, Intelligent Averages Technology, Auto Inflation & Deflation
Akwụkwọ ikike na nkwado
MedeScan products are designed to meet high quality standards. For warranty information and customer support, please refer to the warranty card included with your product or visit the official MedeScan websaịtị.
Ị nwekwara ike ịga na MedeScan Store on Amazon maka ozi ndị ọzọ na nkwado ngwaahịa.