1. Okwu mmalite
This manual provides instructions for the proper use and maintenance of the Dasqua 7 Piece 0-16-Inch Electronic Depth Gage Set, model 4710-1205. This electronic depth gage is designed for precise depth measurements in various industrial and scientific applications. It features a digital display for clear readings and is constructed for durability and accuracy.

Image 1.1: The Dasqua 7 Piece 0-16-Inch Electronic Depth Gage Set, showing the main unit and various measurement rods.
2. Ihe ngwugwu
Chọpụta na akụrụngwa niile dị na ngwugwu:
- Electronic Depth Gage Unit
- Set of Measurement Rods (7 pieces)
- Akpa nchekwa
- Warranty Letter

Image 2.1: The complete Dasqua Electronic Depth Gage Set, including the main unit, measurement rods, and storage case.
3. Atụmatụ igodo
- Mkpebi: 0.0005-inch / 0.01mm for precise measurements.
- Nkwekọrịta Ọkọlọtọ: Manufactured in accordance with DIN863 standards.
- Spindle: Hardened, ground, and lapped for enhanced accuracy.
- Ntughari: Designed to accommodate a broad range of measurement applications.
- Ngosipụta: Large, digital display for clear and quick readings.
- Ihe owuwu: Hardened stainless steel base and rods resist wear, ensuring durability and consistent accuracy.
- Tọgharia efu: Ability to reset to zero at any position for comparative depth measurements.
4. Nhazi ntuziaka
4.1. Ntinye batrị
The electronic depth gage typically uses a CR2032 lithium coin cell battery. To install or replace the battery:
- Locate the battery compartment cover on the back of the digital display unit.
- Use a small screwdriver or coin to open the cover.
- Fanye batrị CR2032 ọhụrụ nwere akụkụ dị mma (+) chere ihu n'elu.
- Dochie mkpuchi nke batrị batrị nke ọma.
4.2. Attaching Measurement Rods
Select the appropriate measurement rod for the desired depth range. The set includes rods of various lengths.
- Identify the threaded end of the measurement rod.
- Carefully screw the rod into the threaded hole at the bottom of the depth gage's base until it is finger-tight. Do not overtighten.
- Ensure the rod is securely attached and straight.

Image 4.1: The electronic depth gage with a measurement rod properly attached to its base.

Image 4.2: A selection of the hardened stainless steel measurement rods provided with the depth gage set.
5. Ntuziaka ọrụ
5.1. Gbanyụọ / gbanyụọ
- Pịa Gbanye/ Gbanyụọ bọtịnụ iji gbanye ngwaọrụ ahụ.
- Pịa Gbanye/ Gbanyụọ button again to power off the device.
5.2. Unit Conversion (Inch/Millimeter)
- Pịa mm/in button to switch between millimeter (mm) and inch (in) units. The selected unit will be displayed on the screen.
5.3. Zero Setting
The zero-reset function allows for comparative measurements or setting a reference point.
- Place the depth gage on a flat, stable reference surface, ensuring the measurement rod is fully retracted or resting on the surface.
- Pịa ZERO button. The display will show '0.000' or '0.00'.
5.4. Iwere nha
- Ensure the depth gage is zeroed on a reference surface.
- Place the base of the depth gage firmly on the surface from which the depth is to be measured.
- Lower the measurement rod into the hole or recess until its tip contacts the bottom.
- Read the measurement directly from the digital display.
5.5. Ọrụ Jide
- Pịa Jide bọtịnụ iji mee ka ọgụgụ dị ugbu a dị na ngosipụta ahụ sie ike.
- Pịa Jide button again to release the reading and return to live measurement.

Foto 5.1: Zuru ezu view of the digital display, showing the ON/OFF, mm/in, HOLD, and ZERO buttons.
6. Nlekọta
6.1. Nhicha
- Wipe the depth gage and rods with a clean, dry, lint-free cloth after each use.
- Maka unyi siri ike, jiri ákwà dị nroampened with isopropyl alcohol. Avoid harsh chemicals or solvents.
- Ensure no liquid enters the electronic components.
6.2. Nchekwa
- Store the depth gage in its protective case when not in use.
- Debe ngwaọrụ ahụ n'ebe kpọrọ nkụ, pụọ na ìhè anyanwụ kpọmkwem, oke okpomọkụ na oke iru mmiri.
- Ọ bụrụ na echekwara ya ruo ogologo oge, wepụ batrị ahụ iji gbochie mmiri ịpụ apụ.
6.3. Ngbanwe batrị
Replace the battery when the display becomes dim or erratic. Refer to Section 4.1 for battery installation instructions.
7. Nchọpụta nsogbu
- Ngosipụta ahụ tọgbọ chakoo ma ọ bụ gbaa ọchịchịrị:
Check battery installation. Replace the battery if necessary. Ensure the device is powered on. - Ọgụgụ na-ezighi ezi:
Ensure the depth gage is properly zeroed on a flat reference surface. Clean the measurement rod and base to remove any debris. Verify the measurement rod is securely attached. - Bọtịnụ anaghị anabata:
Check battery level. If the issue persists after battery replacement, contact customer support.
8. Nkọwapụta ngwaahịa
| Nkọwapụta | Nkọwa |
|---|---|
| Nọmba nlereanya | 4710-1205 |
| Oke nha | 0-16 sentimita / 0-400mm |
| Mkpebi | 0.0005 inch / 0.01mm |
| Izi ezi | 0.0015 inch / 0.03mm |
| Ihe onwunwe | Hardened Stainless Steel |
| Isi Iyi Ike | CR2032 Battery (typical) |
| Akụkụ ngwugwu | 9 x 5 x 2 sentimita asatọ |
| Ibu Ibu | 12.8 ounces |

Image 8.1: Detailed specifications and dimensional diagram for the Dasqua 0-16 inch Electronic Depth Gage Set.
9. Akwụkwọ ikike na nkwado
This product is supplied with a warranty letter. For specific warranty terms and conditions, please refer to the documentation included in your package. For technical support, service, or inquiries regarding your Dasqua 4710-1205 Electronic Depth Gage Set, please contact the manufacturer directly through their official websaịtị ma ọ bụ ọwa ọrụ ndị ahịa.