1. Okwu mmalite
This manual provides detailed instructions for the setup, operation, and maintenance of the Elitech Loget 260-TH 4G Real-time Temperature Humidity Data Logger. This device is designed for monitoring temperature, humidity, light, shock, and location in various cold chain applications, providing real-time data transmission via 4G network.
1.1. Ihe ngwugwu
- Elitech Loget 260-TH Data Logger (Reusable version)
- Built-in 4G SIM Card
- Akwụkwọ ntuziaka onye ọrụ
- USB Type-C USB
2. Ngwaahịa gafereview
The Loget 260-TH is a multi-sensor data logger equipped with a display and control buttons for easy interaction. It features internal sensors for temperature, humidity, light, and shock, along with LBS (Location-Based Service) for location tracking.

Figure 2.1: Elitech Loget 260-TH Data Logger with numbered components.
2.1. Njirimara akụrụngwa
- Ihuenyo ngosi LCD: Shows current readings, status, and alerts.
- Ìhè ihe ngosi LED: Provides visual status updates (e.g., OK, Alarm).
- Activate/Airplane Mode Button: Used to activate the device or toggle airplane mode.
- Ihe mmetụta nke ime: Measures ambient temperature and humidity.
- Back Hanging Hole: For mounting or securing the device.
- Bọtịnụ mmalite/Kwụsị: Initiates or terminates data logging.
- Nọmba usoro n'usoro: Unique identifier for the device.
- Ihe mmetụta ọkụ: Detects ambient light levels.
- Data Transmission Indicator: Shows network activity and data upload status.
2.2. Atụmatụ igodo
- Double Data Security: Features offline storage for up to 100,000 points to prevent data loss and supports shadow data recording for continuous monitoring even if logging is mistakenly stopped.
- Multi-Source Sensing: Monitors internal temperature (-30~60℃), humidity (0~100%RH), light (0~52000Lux), shock (0g~16g), and location (LBS). Optional external sensors for pH value or CO2 are available separately.
- Remote Monitoring via APP/Web: Real-time data is uploaded to the Elitech iCold Cloud platform via a built-in 4G SIM card. Upload intervals are configurable from 1 minute to 24 hours.
- Comprehensive Alarm System: Cloud-based alarms can be received via Elitech iCold APP, SMS, Email, or the web platform. The device also provides local sound, screen, and indicator light alarms for offline events.
- Auto Flight Mode & Electronic Fence: Complies with Do160 for aviation safety. Flight mode can be activated manually, scheduled, or automatically via an electronic fence (custom area activation).
- iCold Platform: A cloud-based platform compatible with RCW series products for real-time monitoring, automatic alerts, online data analysis, and management. It complies with FDA CFR 21 Part 11 requirements and supports iOS and Android apps.
3. Nhazi
3.1. Nchaji mbụ
Before first use, connect the Loget 260-TH to a power source using the provided USB Type-C cable and a standard USB charger (not included) to ensure the internal battery is fully charged. The battery indicator on the LCD will show charging status.
3.2. Device Activation and Platform Connection
- Ike Na: Press and hold the 'Start/Stop' button for a few seconds until the device powers on and the LCD screen illuminates.
- Njikọ netwọk: The built-in 4G SIM card will automatically attempt to connect to the network. The signal strength indicator on the LCD will show connection status.
- iCold Account Setup:
- Download the Elitech iCold APP from your mobile app store or visit the Elitech iCold web ikpo okwu (http://new.i-elitech.com).
- Debanye aha maka akaụntụ ọhụrụ ma ọ bụ banye ma ọ bụrụ na ị nwere otu.
- Add your Loget 260-TH device to your account using the serial number found on the device (refer to Figure 2.1, item 7).
- Nhazi: Once added, you can configure logging parameters such as upload interval, alarm thresholds, and sensor settings via the iCold platform.
4. Ntuziaka ọrụ
4.1. Starting and Stopping Logging
- Malite ịbanye: Press and hold the 'Start/Stop' button until the logging indicator appears on the LCD. The device will begin recording data according to the configured settings.
- Stop Logging: Press and hold the 'Start/Stop' button again until the logging indicator disappears. Data logging will cease.
4.2. Ụdị ụgbọ elu
Airplane mode disables all wireless communication (4G) to comply with aviation regulations. Data logging continues internally.

Figure 4.1: Loget 260-TH illustrating Flight Mode activation methods.
- Ntinye akwụkwọ ntuziaka: Press the 'Activate/Airplane Mode' button (Figure 2.1, item 3) to toggle airplane mode on or off.
- Scheduled Activation: Configure specific times for airplane mode activation via the iCold platform.
- Electronic Fence Activation: Set up a custom geographical area in the iCold platform. The device will automatically enter airplane mode upon entering this area and exit upon leaving.
4.3. Data Access and Alarms

Figure 4.2: Loget 260-TH data displayed on the Elitech iCold mobile application.
- Data ezigbo oge: View live temperature, humidity, light, shock, and location data on the Elitech iCold APP or web ikpo okwu.
- Data akụkọ ihe mere eme: Access and analyze historical data, generate reports (PDF/CSV), and track routes through the iCold platform.
- Ọkwa mkpu: Receive instant alerts via APP, SMS, or Email when configured parameters exceed set thresholds. The device also provides local visual and audible alarms.

Figure 4.3: Elitech iCold platform demonstrating PDF and CSV report export functionality.
5. Nlekọta
5.1. Nlekọta batrị
- Recharge the device regularly, especially if it will be stored for an extended period.
- Avoid exposing the device to extreme temperatures during charging or storage, as this can degrade battery life.
5.2. Nhicha
- Jiri akwa dị nro hichaa ngwaọrụ ahụ.
- Do not use abrasive cleaners or solvents, as these can damage the casing or sensors.
5.3. Nchekwa
- Chekwaa ngwaọrụ ahụ n'ebe dị jụụ, kpọrọ nkụ na-adịghị na ìhè anyanwụ kpọmkwem.
- Ensure the battery is partially charged (around 50%) before long-term storage.
6. Nchọpụta nsogbu
6.1. Ngwaọrụ anaghị agba ọkụ
- Ensure the device is fully charged. Connect it to a power source using the USB Type-C cable.
- Verify that the 'Start/Stop' button is pressed and held for the required duration.
6.2. No 4G Network Connection
- Check the signal strength indicator on the LCD. If weak, move to an area with better network coverage.
- Ensure airplane mode is not active.
- Contact Elitech support if the issue persists, as the built-in SIM card may require troubleshooting.
6.3. Data Not Uploading to iCold Platform
- Confirm the device has a stable 4G connection.
- Verify that the device is correctly added and configured in your iCold account.
- Check the upload interval settings in the iCold platform.
6.4. Ọgụgụ Na-ezighi Ezi
- Ensure the sensors are not obstructed or exposed to direct heat/cold sources that do not reflect the ambient environment.
- Allow the device to stabilize in a new environment for a few minutes before taking critical readings.
7. Nkọwapụta
| Oke | Uru |
|---|---|
| Nọmba nlereanya | US-LogEt260-TH-10PACK |
| Temperature Range (Internal) | -30℃ ruo 60℃ (-22℉ ruo 140℉) |
| Humidity Range (Internal) | 0% ruo 100% RH |
| Oke ihe mmetụta ọkụ | 0 ruo 52000 Lux |
| Shock Sensor Range | 0 g na 16 g |
| Ndepụta ebe | LBS (Location-Based Service) |
| Ike Nchekwa data | 100,000 points (offline) |
| Njikọta | 4G (Built-in SIM Card) |
| Bulite nkeji | Configurable (1 minute to 24 hours) |
| Ụdị batrị | Lithium ion (gụnyere) |
| Interface | USB Ụdị-C |
| nnabata | Do160 (Aviation Safety), FDA CFR 21 Part 11 |
8. Akwụkwọ ikike na nkwado
For warranty information, technical support, or service inquiries, please contact Elitech Technology Inc. directly. Refer to the official Elitech website or the contact information provided with your purchase for the most up-to-date support details.
Platform nke Elitech iCold: http://new.i-elitech.com