1. Ozi nchekwa dị mkpa
Please read these instructions carefully before installation and use. Keep this manual for future reference.
- Nchekwa Eletriki: Always disconnect power at the main circuit breaker before installation, maintenance, or bulb replacement. Consult a qualified electrician if you are unsure about electrical wiring.
- Voltage: Gbaa mbọ hụ na ọkọnọ ọkụ voltage dakọtara na ihe ndozi chọrọ (240V).
- Ụdị bọlbụ: Use only G9 bulbs, maximum 28 Watts. Do not exceed the recommended wattage. Bulbs are not included.
- Nwụnye: This fixture is designed for ceiling mounting. Ensure the mounting surface can support the weight of the chandelier (5.84 kg).
- gburugburu: For indoor use only (IP20 rating). Do not expose to moisture or extreme temperatures.
- Nhicha: Jiri akwa dị nro, kpọrọ nkụ maka nhicha. Ejila ihe nchacha abrasive ma ọ bụ ihe mgbaze.
2. Ngwaahịa gafereview
The MAYTONI Dallas Chandelier (MOD545PL-25B) is a modern decorative lighting fixture designed to enhance various indoor spaces such as living rooms, dining rooms, bedrooms, offices, kitchens, and cafes. Its unique design features a black metal frame with 25 smoked glass spheres, resembling a molecular structure.

Figure 2.1: MAYTONI Dallas Chandelier (MOD545PL-25B) - Overall View.
This chandelier provides bright and pleasant general illumination, suitable for rooms with low ceilings due to its total height of 25 cm and diameter of 75 cm. The shade diameter is 10 cm.
3. Kedu ihe dị na Igbe ahụ
Carefully unpack the box and ensure all components are present and undamaged. If any parts are missing or damaged, contact customer support before proceeding with installation.
- Chandelier frame (black metal)
- 25 Smoked glass spheres (shades)
- Akụrụngwa mgbanye (skru, arịlịka, wdg)
- Akwụkwọ ntuziaka
Note: G9 bulbs are not included and must be purchased separately.
4. Nkọwapụta
| Njirimara | Nkọwa |
|---|---|
| Ụdị | MAYTONI ịchọ mma ọkụ |
| Nọmba nlereanya | MOD545PL-25B |
| Akụkụ ngwaahịa (L x W x H) | 123.5 x 23.8 x 135.4 cm |
| Mgbakọta Ogologo | 25 cm |
| Dayameta | 75 cm |
| Ibu Ibu | 5.84 n'arọ |
| Ihe onwunwe | Metal (frame), Glass (shades) |
| Agba | Black (frame), Smoked (shades) |
| Ụdị | Oge a |
| Ọnụọgụ nke bọlbụ | 25 |
| Ụdị bọlbụ | G9 (anaghị etinye ya) |
| Max Wattage kwa Bulb | 28 Watt |
| Voltage | 240 volts |
| Ogo IP | IP20 (naanị ime ụlọ) |
| Isi Iyi Ike | Igwe ọkụ eletrik |
| Atụmatụ pụrụ iche | Ike dị irè |
5. Ntọala na nwụnye
Tupu ịmalite: Ensure the power supply is turned off at the circuit breaker. It is recommended to have two people for installation due to the size and weight of the fixture.

Figure 5.1: Installation Diagram and Dimensions.
- Kwadebe ụlọ: Mark the drilling points on the ceiling for the mounting bracket (1). Ensure the location is suitable and can support the chandelier's weight.
- Wụnye nkwado nkwado: Drill holes and insert appropriate anchors. Secure the mounting bracket to the ceiling using screws (2).
- Jikọọ Wiring: Carefully connect the chandelier's electrical wires to your household wiring. Ensure correct polarity (Live to Live, Neutral to Neutral, Ground to Ground). Use appropriate wire connectors.
- Jikọọ Canopy: Lift the chandelier and secure the canopy to the mounting bracket using the provided screws (4). Ensure the wires are not pinched.
- Wụnye G9 Bulbs: Insert the G9 bulbs into their respective sockets (3). Gently push and twist to secure.
- Attach Glass Spheres: Carefully attach each smoked glass sphere (6) to its designated holder on the chandelier frame (5). Twist or push to secure, depending on the mechanism.

Figure 5.2: Ceiling Mount Detail.

Figure 5.3: Detail of Glass Spheres and Bulb Sockets.
6. Ntuziaka ọrụ
Once installed, operating your MAYTONI Dallas Chandelier is straightforward:
- Ike Na: Weghachite ike na isi sekit breaker.
- Gbanwuo/ Gbanyụọ: Use your standard wall switch to turn the chandelier on or off.
- Ndokwa bọlbụ: Ensure power is off before replacing any G9 bulbs. Allow bulbs to cool completely before handling.
7. Nlekọta
Nlekọta mgbe niile ga-enyere aka chekwaa ọdịdị na ọrụ nke chandelier gị.
- Nhicha: Disconnect power before cleaning. Use a soft, dry, lint-free cloth to wipe the metal frame and glass spheres. Do not use liquid cleaners, abrasive materials, or chemical solvents, as these can damage the finish.
- Ndokwa bọlbụ: As needed, replace G9 bulbs with new ones of the same type and wattage (max 28W). Always ensure power is off and bulbs are cool before replacing.
- Nyocha: Na-elele njikọ niile na ngwaike na-arị elu kwa oge ka ị hụ na ha nọ na nchekwa.
8. Nchọpụta nsogbu
Ọ bụrụ na ị na-enwe nsogbu na chandelier gị, lee nsogbu na ngwọta ndị a na-ahụkarị:
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Ìhè anaghị agbanwuo |
|
|
| Ìhè flickers |
|
|
| Glass sphere falls off |
|
|
Ọ bụrụ na nsogbu ahụ dịgidere mgbe ịnwale azịza ndị a, biko kpọtụrụ nkwado ndị ahịa.
9. Akwụkwọ ikike na nkwado
Akwụkwọ ikike: This MAYTONI product comes with a 2-year warranty from the date of purchase, covering manufacturing defects. Please retain your proof of purchase for warranty claims.
Nkwado ndị ahịa: For any questions, concerns, or assistance with installation or troubleshooting, please contact MAYTONI customer service. Our dedicated team is ready to help you create the perfect lighting solution for your home or business.
You can visit the MAYTONI brand store for more information: MAYTONI Brand Store