AMTAST AMT158

Ntuziaka Onye Ọrụ nke Mita Ọrụ Mmiri AMTAST AMT158

1. Okwu mmalite

This manual provides detailed instructions for the AMTAST AMT158 Portable Water Activity Meter. It covers the product's features, technical specifications, proper setup, operational procedures, maintenance guidelines, and troubleshooting steps. Please read this manual thoroughly before using the device to ensure accurate measurements and safe operation.

2. Ngwaahịa gafereview

2.1 Atụmatụ

  • Fechaa & Portable: Weighing approximately 275 grams, the meter is designed for easy transport and on-the-go testing.
  • Accurate & Reliable Measurements: Offers a measurement range of 0-1.0aw with a resolution of ±0.01aw and an accuracy of ±0.02aw for precise water activity analysis.
  • Ihe mmetụta agbakwunyere: Features a non-conductive humidity sensor and integrated readings within a single unit, simplifying the measurement process.
  • Quick Testing Process: Provides rapid results, completing water activity measurements within approximately 5 minutes.
  • Convenient Display & Functions: Equipped with a 6-digit backlit LCD screen displaying both water activity (aw) and temperature simultaneously. Includes automatic and manual shut-off options, and a low battery indicator.

2.2 Akụkụ

The AMTAST AMT158 Water Activity Meter package typically includes the main unit (host), a sample plate, a portable carrying bag, and this instruction manual.

AMTAST AMT158 Water Activity Meter in a laboratory setting
Foto 1: AMTAST AMT158 Water Activity Meter in a laboratory setting, illustrating its function to measure free water activity for food and medicine preservation. The image also shows a sample plate, which is a key component.

3. Nkọwapụta

OkeUru
Oke nha0 ~ 1.0aw
Mkpebi± 0.01aw
Izi ezi± 0.02aw
SampOgologo ogeNkeji 5
Okpomọkụ na-arụ ọrụ0 ~ 50℃ (32 ~ 122℉)
Iru mmiri na-arụ ọrụ<95% RH (na-adịghị ekpokọta)
Ịnye ọkụ2 x 1.5V AAA Size (UM-4) Battery
Akụkụ145 x 77 x 30mm (5.7 x 3.0 x 1.2 sentimita)
Ibu (na-enweghị batrị)275g (0.61 lbs)
Diagram showing the dimensions and specifications of the AMTAST AMT158 Water Activity Meter
Foto 2: Diagram illustrating the physical dimensions (5.7 inches height, 3.0 inches width) and key technical specifications of the AMTAST AMT158 Water Activity Meter.

4. Nhazi

4.1 Ntinye batrị

  1. Chọta mkpuchi nke batrị n'azụ ngwaọrụ.
  2. Mee ka mkpuchi ahụ dị mfe ma ọ bụ gbapụ iji mepee ya.
  3. Insert two (2) 1.5V AAA (UM-4) batteries, ensuring correct polarity (+/-) as indicated inside the compartment.
  4. Dochie mkpuchi nke batrị batrị nke ọma.

Note: Batteries are not included in the package due to aviation security regulations.

Battery compartment and sensor of the AMTAST AMT158 Water Activity Meter
Foto 3: Zuru ezu view of the AMTAST AMT158 Water Activity Meter's battery compartment, showing where to insert the 2x1.5V AAA batteries, and the non-conductive humidity sensor.

4.2 Nyocha mbụ

Before first use, inspect the device for any visible damage. Ensure the sample plate is clean and free from debris. The sensor should also be clean and unobstructed.

5. Ọrụ

5.1 Gbanyụọ/ gbanyụọ

  • To power on the device, press the power button (usually marked with a ⑂ symbol). The backlit LCD screen will illuminate.
  • The device features an automatic shut-off function to conserve battery power. To manually shut off the device, press and hold the power button until the display turns off.

5.2 Inyocha ihe

  1. Gbaa mbọ hụ na sample plate is clean and dry.
  2. Place a small, representative sample of the material to be tested onto the sample plate. Ensure the sample covers the sensor area adequately without overflowing.
  3. Close the meter's lid or place the main unit onto the sample plate, ensuring a tight seal to create a closed environment for accurate measurement.
  4. The measurement process will begin automatically or may require a button press (refer to specific on-screen prompts if any). The device will typically take approximately 5 minutes to stabilize and display the final water activity (aw) and temperature readings.
  5. Once the reading is stable, record the displayed values.
  6. After measurement, remove the sample and clean the sample plate and sensor area immediately.
Close-up of the AMTAST AMT158 Water Activity Meter's backlit LCD screen
Foto 4: Close-up of the AMTAST AMT158 Water Activity Meter's backlit LCD screen, clearly displaying both the water activity (aw) value and the temperature.
AMTAST AMT158 Water Activity Meter emphasizing quick 5-minute measurement
Foto 5: The AMTAST AMT158 Water Activity Meter highlighting its quick and efficient measurement capability, completing tests within 5 minutes.

5.3 Ngwa

The AMTAST AMT158 Water Activity Meter is suitable for measuring water activity in a wide range of products, including but not limited to:

  • Dried fruits and vegetables
  • Beef jerky and other dried meats
  • Baked goods like cookies
  • Sausages and processed meats
  • Grains, nuts, and spices
Collage of food items illustrating the wide application of the AMTAST AMT158 Water Activity Meter
Foto 6: A visual representation of various food products such as dried fruit, beef jerky, cookies, and sausage, demonstrating the broad utility of the AMTAST AMT158 Water Activity Meter in different food applications.

6. Nlekọta

6.1 Nhicha

  • After each use, carefully clean the sample plate and the area around the sensor with a soft, dry cloth.
  • Do not use abrasive cleaners or solvents, as these can damage the sensor or the device's casing.
  • Ensure no liquid enters the device's internal components.

6.2 Nchekwa

Store the meter in a clean, dry environment, away from direct sunlight and extreme temperatures. When storing for extended periods, remove the batteries to prevent leakage.

6.3 nnọchi batrị

When the low battery indicator appears on the display, replace both AAA batteries promptly to ensure continued accurate operation. Refer to Section 4.1 for battery installation instructions.

7. Nchọpụta nsogbu

NsogbuIhe nwere ike imeNgwọta
Ngwaọrụ anaghị agbanwu ọkụBatrị nwụrụ anwụ ma ọ bụ arụnyere na ezighi eziLelee polarity batrị; dochie ya na batrị ọhụrụ.
Ọgụgụ na-ezighi ezi ma ọ bụ na-ekwekọghị ekwekọ
  • Ihe mmetụta sensọ
  • Na-ekwesịghị ekwesị sample ọnye
  • Device not calibrated (if applicable)
  • Environmental interference (temperature/humidity outside operating range)
  • Hichaa ihe mmetụta na sample plate thoroughly.
  • Gbaa mbọ hụ na sample covers the sensor and the lid is sealed.
  • If calibration is required, refer to specific calibration instructions (not covered in this general manual).
  • Ensure operating conditions are within specified ranges (0-50℃, <95%RH).
Display shows 'Low Battery'Batrị dị alaReplace both 1.5V AAA batteries.
Ngwaọrụ na-eti mkpu mgbe niilePossible internal error or battery issueRemove and reinsert batteries. If the issue persists, contact customer support.

8. Akwụkwọ ikike na nkwado

For warranty information, technical support, or service inquiries, please contact the manufacturer or your authorized dealer. Keep your purchase receipt as proof of purchase.

You can visit the official AMTAST store for more information: AMTAST Store on Amazon

Akwụkwọ ndị emetụtara - AMT158

Tupuview Ntuziaka Ntuziaka maka Nnyocha Nlele Elu AMTAST
Akwụkwọ ntuziaka zuru oke maka AMTAST Surface Roughness Tester, na-akọwapụta atụmatụ ya, ọrụ ya, mmezi ya, nsogbu ya, na nkọwapụta teknụzụ maka nyocha udidi elu ziri ezi.
Tupuview Nduzi maka Ịwụnye, Ọrụ, na Nchọpụta Nsogbu nke AMTAST
Ntuziaka zuru oke maka AMTAST Water Timer, na-ekpuchi ngwaahịa dị n'eluview, nkọwapụta, ntinye, ntọala mmemme ịgba mmiri akpaka, ịgba mmiri aka, igbu oge mmiri ozuzo, mkpọchi ụmụaka, na ajụjụ ndị a na-ajụkarị.
Tupuview Ntuziaka Ngwaahịa nke AMT-105 Temometa Mkpu n'ime/n'èzí
Ntuziaka ngwaahịa maka temometa mkpu dị n'ime/n'èzí AMTAST AMT-105, nkọwapụta ya, nkọwapụta ya, usoro ntinye, na ntuziaka ọrụ.
Tupuview Mita pH nke Amtast AMT620 Lab - Atụmatụ na Nkọwapụta
Ozi zuru ezu gbasara mita pH nke Amtast AMT620 Lab, gụnyere atụmatụ ya dịka nkwụghachi okpomọkụ pH akpaaka/aka, ọrụ GLP, ikike ịchekwa data, na nkwukọrịta RS232. E nyere nkọwapụta maka oke pH, mV, na oke okpomọkụ na izi ezi.