1. Okwu mmalite
The AOPUTTRIVER AP-9000B is a high-precision ammonia gas detector designed for continuous quantitative analysis of ammonia (NH3) concentration. It features an imported electrochemical principle ammonia gas sensor, offering fast response speed, high accuracy, good stability, and excellent repeatability. This device is equipped with a large LCD display, sound and light dual alarms, and is USB rechargeable, making it suitable for various industrial and agricultural applications.
2. Akụrụngwa Ngwaahịa
- High-precision Ammonia Detection: Measures ammonia concentration from 0 to 100 PPM with a resolution of 0.1 PPM and an accuracy of +/- 2%.
- Ambient Temperature Measurement: Monitors ambient temperature from -10°C to 50°C.
- Sound & Light Dual Alarms: Features customizable alarm thresholds. When the preset ammonia level is reached, a red light indicator and an audible beep sound simultaneously alert the user.
- USB enwere ike ịchaji: Equipped with a built-in rechargeable lithium battery and includes a USB charging cable for continuous operation and reduced long-term costs.
- Ndekọ data: Stores up to 180 sets of historical data, recording ammonia concentration readings every minute for environmental condition monitoring.
- Ngosipụta LCD agba: Provides clear and easy-to-read information.

Nyocha 2.1: N'eluview of the AP-9000B Ammonia Gas Detector's key features.
3. Kedu ihe dị na Igbe ahụ
Mgbe ịmepechara ngwugwu ahụ, biko chọpụta na agụnyere ihe niile ndị a:
- 1 x igbe nkwakọ ngwaahịa
- 1 x ntuziaka ntuziaka
- 1 x eriri nchaji
- 1 x AOPUTTRIVER AP-9000B Ammonia Tester
- 1 x Akpa nchekwa

Figure 3.1: Contents of the AP-9000B package.
4. Nhazi
4.1 Ntinye batrị
Before initial use, ensure the battery is correctly installed. If the battery is not pre-installed or needs replacement, follow these steps:
- Use a small screwdriver to unscrew the battery cover on the back of the device.
- Connect the battery to the interface inside the compartment.
- Tighten the battery cover securely.

Figure 4.1: Battery installation steps.
4.2 Ịchaji ngwaọrụ
The AP-9000B is equipped with a rechargeable lithium battery. To charge the device:
- Chọta ọdụ ụgbọ mmiri chaja USB dị na ngwaọrụ ahụ.
- Connect the provided USB charging cable to the device and a suitable USB power source (e.g., computer, USB wall adapter).
- The battery indicator on the display will show the charging status. Charge until the battery icon indicates a full charge.

Figure 4.2: Charging the AP-9000B via USB.
5. Ntuziaka ọrụ
5.1 Gbanyụọ ma ọ bụ gbanyụọ
- Iji gbanye: Pịa ma jide OK button until the device powers on and the display illuminates.
- Iji gbanyụọ: From the main display, press and hold the OK button. The device will prompt for confirmation to power off. Press OK ọzọ iji gosi.
5.2 Ozi ngosi
The color LCD display provides real-time information:
- Ụbọchị na oge: Shown at the top of the screen.
- Ọkwa batrị: Indicator at the top right.
- NH3 Concentration: Large digits display the current ammonia level in PPM.
- Ọnọdụ dị ugbu a: Indicates 'Normal' or 'Alarm' status.
- Uru kacha elu: Displays the peak ammonia concentration detected.
- Okpomọkụ: Current ambient temperature in °C or °F.
- iru mmiri: Current relative humidity (RH%).

Figure 5.1: Main display interface of the AP-9000B.
5.3 Nhazi na Ntọala NchNhr
The device features a menu for various settings and data review:
- ENT/▼ Key: Long press to enter the setting function. Short press in the setting state to activate the downward function or navigate through options.
- ESC/▲ Key: Short press to activate the upward function or navigate through options.
- Igodo OK: Press to confirm selections or enter sub-menus.
The settings interface includes options for:
- Display Settings (SET DISP)
- Alarm Settings (SET ALARM) - Adjust high and low alarm thresholds.
- Scheduled Shutdown (TIM SHUT)
- Alarm Mode (ALA MODE) - Select Light, Vibration, or Sound.
- System Time (SYS TIME)
- Historical Data (HIS DATA) - Review echekwabara agụ.
Video 5.2: Demonstration of the AP-9000B's button functions and menu navigation for settings and data review.
6. Ngwa
The AOPUTTRIVER AP-9000B Ammonia Gas Detector is versatile and can be used in a wide range of environments where ammonia monitoring is critical. Its applications include:
- Metallurgy
- Osisi ọkụ
- Farms (Poultry, Pig, Livestock)
- Ogwugwu
- Osisi kemịkalụ
- Scientific Research Facilities
- Healthcare and Pharmaceutical Industries
- Environmental Protection Monitoring

Figure 6.1: Diverse applications of the AP-9000B Ammonia Gas Detector.
7. Safety Information: Hazards of Ammonia
Ammonia (NH3) is a hazardous gas. Understanding its concentration levels and associated risks is crucial for safety. The AP-9000B helps monitor these levels to prevent exposure to dangerous concentrations.
| Concentration (PPM) | Ihe ize ndụ nwere ike ime |
|---|---|
| 5 ppm | Sensory odor threshold; some individuals may detect it. |
| 20 ppm | Significant irritation in most people, generally not harmful with short exposure. |
| 20-30 nkeji | Time-weighted safety thresholds for occupational exposure. |
| 100 ppm | Discomfort for most people, not harmful with limited exposure. |
| 250 ppm | Irritation of nose, throat, eyes, and other senses. |
| 400 ppm | Eye pain, tearing for 30 minutes. |
| 700 ppm | Limit of human tolerance; prolonged exposure should be avoided. |
| 2500 ppm | Intense coughing, irritation of nose, throat, etc.; may lead to death in 15 minutes. |
| 5000 ppm | Causes spasmodic dyspnea, asphyxiation, and rapid death. |

Figure 7.1: Ammonia concentration hazard levels.
8. Nlekọta
To ensure the longevity and accuracy of your AOPUTTRIVER AP-9000B Ammonia Gas Detector, follow these maintenance guidelines:
- Nhicha mgbe niile: Wipe the device exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Nlekọta ihe mmetụta: Avoid exposing the sensor area to dust, dirt, or liquids, which can affect its performance.
- Njikwa batrị: Recharge the battery when the low battery indicator appears. Avoid fully discharging the battery frequently to prolong its lifespan. If replacing the battery, refer to Section 4.1.
- Nchekwa: Mgbe a naghị eji ya ruo ogologo oge, debe ngwaọrụ ahụ n'ebe dị jụụ ma kpọọ nkụ, ebe anwụ na-anaghị apụta kpọmkwem ma ọ bụ oke okpomọkụ.
- Nhazi For professional applications requiring high accuracy, periodic calibration by qualified personnel may be necessary. Refer to the full technical manual for calibration procedures if applicable.
9. Nchọpụta nsogbu
If you encounter issues with your AP-9000B, refer to the following common troubleshooting steps:
- Ngwaọrụ anaghị agba ọkụ: Ensure the battery is charged. Connect the device to a USB charger and try again. Check if the battery is correctly installed (refer to Section 4.1).
- Ọgụgụ na-ezighi ezi: Ensure the sensor area is clean and unobstructed. Avoid using the device in environments with extreme temperature or humidity fluctuations outside its operating range. Allow the device to stabilize in the environment for a few minutes before taking readings.
- Mkpu Anaghị arụ ọrụ: Check the alarm settings in the menu (SET ALARM, ALA MODE) to ensure they are configured correctly and the volume/vibration is enabled.
- Ihe ngosi: If the display is dim or flickering, ensure the battery is charged. If the issue persists, contact customer support.
- Bọtịnụ anaghị anabata: Try restarting the device. If buttons remain unresponsive, contact customer support.
For persistent issues not covered here, please contact AOPUTTRIVER customer support.
10. Nkọwapụta
| Njirimara | Nkọwapụta |
|---|---|
| Ụdị | AOPUTTRIVER |
| Nọmba nlereanya | AP-9000B |
| Ammonia Measuring Range | 0 ~ 100 PPM |
| Mkpebi | 0.1 PPM |
| Izi ezi | +/- 2% |
| Measurement Ambient Temperature Range | -10 ~ 50 Celsius |
| Iru mmiri na-arụ ọrụ | 0-95% RH |
| Typedị Oti mkpu | Sound & Light Dual Alarm |
| Isi Iyi Ike | USB Rechargeable Lithium Battery |
| Nchekwa data | Up to 180 sets of data (1-minute interval) |
| Ibu Ibu | 3.2 ounces (ihe dị ka gram 90.7) |
| Akụkụ ngwugwu | 8 x 6 x 3 sentimita asatọ |