Sartorius GL2202i-2S

Sartorius GL2202i-2S Gold Scale User Manual

Model: GL2202i-2S | Brand: Sartorius

1. Okwu mmalite

This manual provides comprehensive instructions for the proper setup, operation, and maintenance of the Sartorius GL2202i-2S Gold Scale. Adhering to these guidelines will ensure accurate and reliable performance of your precision weighing instrument.

2. Ozi nchekwa

Observe the following safety precautions to prevent injury and damage to the device:

3. Ngwaahịa gafereview

The Sartorius GL2202i-2S is a precision gold scale designed for accurate weighing applications. Key components include the weighing pan, digital display, and control panel.

Sartorius GL2202i-2S Gold Scale with weighing pan and digital display

Figure 1: Sartorius GL2202i-2S Gold Scale. This image shows the scale's stainless steel weighing pan, the digital display, and the control buttons for operation.

Isi Components:

4. Nhazi

4.1 Nwepu

Carefully remove the scale and all accessories from the packaging. Retain the original packaging for future transport or storage.

4.2 Ntinye

Place the scale on a firm, stable, and level surface. Avoid locations subject to:

4.3 Ịkwalite Ọkwa

Adjust the leveling feet located at the bottom of the scale until the air bubble in the level indicator (usually located near the display) is centered. This ensures accurate weighing results.

4.4 Njikọ ike

Connect the provided power adapter to the scale's power input and then to a suitable electrical outlet. Allow the scale to warm up for at least 30 minutes after initial power-on for optimal stability.

5. Ntuziaka ọrụ

5.1 Gbanyụọ ma ọ bụ gbanyụọ

Pịa Ike button (often marked with a circle and a vertical line) to turn the scale on or off. The display will show a self-test sequence before settling at zero.

5.2 Ibu Ibu Dị Mkpa

  1. Ensure the display reads 0.00 g before placing any item on the pan.
  2. Carefully place the item to be weighed onto the center of the weighing pan.
  3. Wait for the reading to stabilize. The stable reading will be displayed.
  4. Remove the item from the pan.

5.3 Tare arụ ọrụ

The tare function allows you to weigh items in a container by subtracting the container's weight.

  1. Place the empty container on the weighing pan.
  2. Pịa Tare button (often marked with a 'T' or '->0<-'). The display will reset to 0.00 g.
  3. Add the item to be weighed into the container. The display will show the net weight of the item.
  4. Remove both the item and container from the pan.

6. nhazi nhazi

The Sartorius GL2202i-2S features an automatic, built-in calibration and adjustment function. Regular calibration ensures the highest level of accuracy. Refer to the on-screen prompts or the scale's specific menu for initiating the automatic calibration process. Ensure the scale is stable and free from any load during calibration.

7. Nlekọta na nhicha

7.1 Nhicha

To maintain the scale's performance and appearance:

7.2 Nchekwa

If storing the scale for an extended period, ensure it is clean, dry, and stored in its original packaging or a protective container in a stable environment.

8. Nchọpụta nsogbu

Akụkụ a na-ekwu maka nsogbu ndị ị nwere ike izute. Maka nsogbu edepụtaghị ebe a, kpọtụrụ nkwado ndị ahịa.

NsogbuIhe nwere ike imeNgwọta
Display shows "Err" or unstable readings.Scale not level, vibrations, drafts, overload, or internal error.Check leveling, move to a stable location, ensure no load exceeds capacity, restart the scale.
Scale does not power on.Power cable disconnected, faulty outlet, or power adapter issue.Verify power cable connection, try a different outlet, check power adapter.
Ọgụgụ na-ezighi ezi.Needs calibration, environmental factors, or dirty pan.Perform calibration, ensure stable environment, clean weighing pan.

9. Nkọwapụta

10. Akwụkwọ ikike na nkwado

For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact Sartorius customer service directly. Keep your purchase receipt and model number readily available when contacting support.

Akwụkwọ ndị emetụtara - GL2202i-2S

Tupuview Sartorius CP | Gemplus Series eletrọnịkị nha nha - ntuziaka ọrụ
Ntuziaka ọrụ zuru oke maka Sartorius CP | Usoro Gemplus eletrọnịkị micro-, nyocha, na nguzozi ziri ezi, gụnyere CPA, GCA, na ụdị GPA. Na-ekpuchi nrụnye, ọrụ, nhazi, mmemme ngwa, nchọpụta nsogbu, mmezi na nkọwapụta.
Tupuview Sartorius Portable and Gold Series Service Manual: Maintenance and Repair Guide
Comprehensive service manual for Sartorius Portable and Gold series weighing scales (PT...-000V1 and GT...-G00V1). Covers adjustment, calibration, repair procedures, troubleshooting, and data interface information for service technicians.
Tupuview Onye ndu Sartorius CP Gemplus: Istruzioni kwa Bilance Analitiche e di Precisione
Ntuziaka zuru oke maka otu onye ọ bụla si elettroniche Sartorius CP na Gemplus (modelli CPA, GCA, GPA). Gbanyụọ installazione, egwuregwu, impostazioni, manutenzione na kpọmkwem ihe eji eme ihe.
Tupuview Sartorius PR 5230 Transmitter in Field Housing - Instrument Manual
Comprehensive instrument manual for the Sartorius PR 5230 Transmitter in Field Housing. Covers installation, operation, calibration, safety, and technical specifications for industrial weighing applications.
Tupuview Sartorius Secura, Quintix, Practum Laboratory Balances Akwụkwọ ntuziaka onye ọrụ
Akwụkwọ ntuziaka onye ọrụ zuru oke maka Sartorius Secura, Quintix, na nguzo ụlọ nyocha Practum. Nwụnye nkọwa, ọrụ, ntuziaka nchekwa, ngwa nha dị iche iche, ntọala sistemụ na nkọwa nka maka nha ụlọ nyocha.
Tupuview Sartorius CP | Gemplus Series Operating Instructions: CPA, GCA, GPA Models
Comprehensive operating instructions for Sartorius CP | Gemplus Series electronic micro-, analytical, and precision balances, including CPA, GCA, and GPA models. Covers installation, operation, configuration, application programs, and maintenance.