1. Okwu Mmalite na Product Overview
Thank you for choosing the BE COOL BC50LEF2301 50L Dehumidifier. This appliance is designed to efficiently remove excess moisture from the air in your home or commercial space, improving air quality and preventing issues like mold and mildew. This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your dehumidifier.
Key features of your BE COOL BC50LEF2301 dehumidifier include:
- Powerful dehumidification: Removes up to 50 liters of moisture per day.
- Suitable for large areas: Effective in rooms up to 125 m³ (50 m²).
- User-friendly touch panel with LED display.
- Adjustable humidity levels from 30% to 80%.
- Igwe nju oyi R290 maka gburugburu ebe obibi.
- Ọrụ ngụ oge 24.
- Ọrụ mwepu akpaaka.
- Full water tank alarm and automatic shut-off.
- 7-liter removable water tank.
- Integrated dust filter.
- Ike gitage memory function.
- Equipped with wheels for easy mobility.

2. Ntuziaka nchekwa
Biko gụọ ntuziaka nchekwa niile nke ọma tupu i jiri ngwa ahụ iji gbochie mmerụ ahụ ma ọ bụ mmebi. Debe akwụkwọ ntuziaka a maka ntụaka n'ọdịnihu.
- Nchekwa Eletriki: Gbaa mbọ hụ na ọkọnọ ike dabara na voltage specified on the rating label. Do not operate the unit with a damaged power cord or plug. Do not share the power outlet with other appliances.
- Nkwanye: Place the dehumidifier on a flat, stable surface. Maintain at least 20 cm (8 inches) clearance around the unit for proper airflow. Do not block air inlets or outlets.
- Igwe nju oyi: This appliance uses R290 refrigerant. Do not puncture the refrigerant circuit. Servicing should only be performed by qualified personnel.
- tank mmiri: Always empty the water tank before moving the unit. Do not drink the collected water.
- Ụmụaka na anụ ụlọ: Debe ụmụaka na anụ ụlọ pụọ na ngwa ngwa mgbe a na-arụ ọrụ.
- Nhicha: Wepụ ihe mkpuchi ahụ mgbe niile tupu ị sachaa ma ọ bụ rụzie ihe ọ bụla.
- Ọnọdụ ọrụ: Do not operate the unit in extremely high temperatures or in direct sunlight. The recommended operating temperature range is 5-32°C.
3. Ngwa ngwaahịa
Mara onwe gị nke ọma akụkụ ndị bụ isi nke ikuku ikuku gị:
- Ogwe njikwa: Located on the top, with touch buttons and an LED display.
- Ọpụpụ ikuku: Top front, where dry air is expelled.
- Ikuku ụgbọ mmiri: Rear, where humid air is drawn in.
- Nzacha uzuzu: Located behind the air inlet, removable for cleaning.
- tank mmiri: Removable tank at the bottom front for collecting condensed water.
- Ọpụpụ mmiri na-aga n'ihu: (If applicable) Located at the rear for connecting a drain hose.
- Wheel: Maka mfe ije nke unit.
- Jikwaa: Aka ejikọtara ọnụ maka ibugharị.


4. Nhazi
- Iwepu: Carefully remove the dehumidifier from its packaging. Retain the packaging materials for future storage or transport.
- Nkwanye:
- Debe unit ahụ kwụ ọtọ n'elu elu siri ike, dị larịị.
- Ensure there is at least 20 cm (8 inches) of free space around the unit to allow for adequate air circulation.
- Avoid placing the unit near heat sources, in direct sunlight, or in areas prone to splashing water.
- For optimal performance, operate the unit within the recommended temperature range of 5-32°C.
- Njikọ ike: Tinye eriri ọkụ eletrik n'ime oghere ọkụ eletrik nke e ji ala kpụọ. Hụ na oghere ọkụ eletrik ahụ ruru ihe achọrọ maka ike nke ngwaọrụ ahụ.
- Ojiji mbụ: After transport, allow the unit to stand upright for at least 2 hours before plugging it in and turning it on. This allows the refrigerant to settle.
5. Ntuziaka ọrụ
The BE COOL BC50LEF2301 features an intuitive touch control panel and LED display for easy operation.

5.1 Ọrụ Panel Control
- bọtịnụ ike (⏻): Pịa ka ịgbanwuo ma ọ bụ gbanyụọ unit ahụ.
- Bọtịnụ ọnọdụ (M): Cycles through different operating modes (e.g., Auto, Continuous, Drying).
- Humidity Setting (%): Adjusts the desired humidity level from 30% to 80% in 5% increments.
- Bọtịnụ Ọsọ Fan (☰): Selects between two fan speeds (High/Low).
- Bọtịnụ ihe eji agụ oge (⏱): Sets the 24-hour timer for automatic power ON or OFF.
- Ikanam Display: Shows current humidity, set humidity, or timer settings.
5.2 Tọọ iru mmiri achọrọ
Press the Humidity Setting button (%) repeatedly to cycle through desired humidity levels. The display will show the selected percentage. The unit will operate until the room humidity reaches the set level, then pause. It will resume operation if the humidity rises above the set level.

5.3 Ọrụ ngụ oge
The 24-hour timer allows you to set a specific time for the unit to turn ON or OFF automatically.
- Iji tọọ Nchekwa Onwe: While the unit is ON, press the Timer button. Use the humidity setting buttons (or dedicated timer adjustment buttons if present) to set the desired number of hours (1-24) after which the unit will turn off.
- Iji tọọ Auto-ON: While the unit is OFF, press the Timer button. Set the desired number of hours (1-24) after which the unit will turn on.
5.4 Water Tank Full Alarm and Auto Shut-off
When the 7-liter water tank is full, the unit will automatically stop operating, and an alarm will sound (beep). The LED display may also indicate a full tank. Empty the water tank and reinsert it correctly to resume operation.

5.5 Mgbapu na-aga n'ihu
For extended operation without needing to empty the water tank, you can connect a drain hose to the continuous drainage outlet at the rear of the unit. Ensure the hose is sloped downwards to allow gravity drainage into a suitable receptacle or floor drain.
5.6 Defrost Ọrụ
The unit is equipped with an automatic defrost function. If frost builds up on the evaporator coils, the unit will temporarily stop dehumidifying and run the fan to melt the frost. Dehumidification will resume automatically once the defrost cycle is complete.

6. Nlekọta
Ndozi mgbe niile na-eme ka arụ ọrụ kacha mma na-agbatịkwu ogologo ndụ nke dehumidifier gị.
6.1 Nhicha Nzacha Uzuzu
- Gbanyụọ ngwaọrụ ahụ ma wepụ ya na ebe ọkụ eletrik.
- Locate the air inlet grille at the rear of the unit.
- Wepu uzuzu uzuzu.
- Clean the filter with a vacuum cleaner or wash it with warm, soapy water. Rinse thoroughly and allow it to air dry completely before reinserting.
- Reinsert the dry filter and close the grille.
Recommendation: Clean the dust filter every two weeks or more frequently depending on usage and air quality.
6.2 Na-ekpochapụ tankị mmiri
- When the water tank is full, the unit will stop operating and alert you.
- Jiri nlezianya wepụ tank mmiri ahụ n'ihu nke unit ahụ.
- Gbanyụọ mmiri ahụ anakọtara.
- Clean the tank periodically with mild detergent and water to prevent mold growth. Rinse thoroughly.
- Reinsert the empty tank firmly into the unit. Ensure it is correctly seated to allow the unit to resume operation.
6.3 Ihicha Unit Mpụga
Jiri nwayọ hichaa mpụta nke otu ahụ, damp cloth. Do not use harsh chemicals, abrasive cleaners, or solvents, as these can damage the surface.
6.4 Nchekwa
Ọ bụrụ na ị na-echekwa ngwaọrụ ahụ ruo ogologo oge:
- Unplug the unit and empty the water tank.
- Clean the dust filter and the exterior.
- Allow the unit to dry completely for at least 24 hours in a well-ventilated area.
- Store the unit upright in a cool, dry place, preferably in its original packaging.
7. Nchọpụta nsogbu
Tupu ịkpọtụrụ nkwado ndị ahịa, biko rụtụ aka na ntuziaka nchọpụta nsogbu ndị a maka okwu nkịtị:
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Unit anaghị agbanwuo. | Enweghị ọkụ. Ejikọghị eriri ọkụ nke ọma. Water tank full or not correctly inserted. | Lelee oghere ọkụ na ihe nbibi sekit. Gbaa mbọ hụ na etinyere eriri ọkụ na nchekwa. Empty water tank and reinsert it correctly. |
| Unit is running but not dehumidifying. | Room temperature too low (below 5°C). Ihe nzacha ikuku mechiri. Ntọala iru mmiri dị elu karịa iru mmiri dị ugbu a. Ọnụ ụzọ/ime windo mepere emepe. | Operate unit within recommended temperature range. Hichaa nzacha ikuku. Set desired humidity lower than current room humidity. Close doors and windows to isolate the room. |
| Ihe ngosi zuru oke nke tank mmiri dị, mana tank adịghị eju. | Water tank not correctly inserted. Float switch malfunction. | Remove and reinsert the water tank firmly. Kpọtụrụ nkwado ndị ahịa ma ọ bụrụ na nsogbu ka dị. |
| Ngalaba na-eme mkpọtụ. | Unit abụghị n'elu larịị. Ihe nzacha ikuku mechiri. Okwu gbasara akụrụngwa. | Tinye otu n'elu larịị, kwụsiri ike. Hichaa nzacha ikuku. Kpọtụrụ nkwado ndị ahịa. |
| Frost on coils. | Okpomọkụ ụlọ dị oke ala. | The unit's automatic defrost function should activate. If not, turn off the unit and allow it to defrost naturally. Ensure operating temperature is above 5°C. |
If the problem persists after trying these solutions, please contact BE COOL customer support.
8. Nkọwapụta
| Njirimara | Nkọwapụta |
|---|---|
| Ụdị | Dị jụụ |
| Nọmba nlereanya | BC50LEF2301 |
| Dehumidification ikike | Approx. 50 Liters/24h |
| Ike tank mmiri | 7 lita |
| Ike | 680 Watt |
| Nha ime ụlọ akwadoro | Ruo 125 m³ (50 m²) |
| Akụkụ ngwaahịa (L x W x H) | 26.6 x 37.8 x 61.5 cm |
| Ibu Ibu | 19 kilogram |
| Ihe onwunwe | Plastic |
| Igwe nju oyi | R290 (ihe gbasara gburugburu ebe obibi) |
| Ọsọ ndị fan | 2 |
| Atụmatụ pụrụ iche | Two fan levels, Dust filter, Full water tank alarm, Defrost function, Power outage memory, 24-hour timer, Touch panel, Removable tank, Wheels. |

9. Akwụkwọ ikike na nkwado
This BE COOL dehumidifier comes with a standard manufacturer's warranty. Please refer to the warranty card included with your purchase for specific terms and conditions, including warranty period and coverage details.
For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact BE COOL customer support. Contact information can typically be found on the product packaging, the official BE COOL websaịtị, ma ọ bụ risit ịzụrụ ihe gị.
When contacting support, please have your model number (BC50LEF2301) and purchase date ready.