1. Okwu mmalite
This manual provides comprehensive instructions for the installation, operation, and maintenance of the Growatt SPH 5000TL3 BH UP Hybrid Inverter. Please read this manual thoroughly before installation and operation to ensure proper use and safety.
The compact Growatt SPH 5000TL3 BH UP inverter features a maximum PV power of 7500 W and a 2 MPP tracker. It boasts a maximum efficiency of 97.2%. The OLED touchscreen allows for simple and modern operation. The device offers 24-hour self-consumption monitoring and is suitable for photovoltaic installations in residential settings.
Akụkụ ndị bụ isi:
- 100% three-phase unbalanced output
- Intelligent phase-level power export limitation
- Wide battery voltage ogologo: 100-550 V
- UPS function, 10ms transition
- VPP dị njikere
2. Ozi nchekwa
Ntuziaka nchekwa dị mkpa: Read and follow all instructions carefully. Keep this manual for future reference.
- Naanị ndị ọrụ ruru eru ga-arụrịrị nrụnye.
- Ensure all electrical connections comply with local and national electrical codes.
- Do not attempt to repair the inverter yourself. Refer all servicing to qualified service personnel.
- Disconnect all power sources before performing any maintenance or installation procedures.
- The inverter can generate high voltages and currents. Exercise extreme caution.
- Gbaa mbọ hụ na ntọala nke inverter kwesịrị ekwesị.
- Do not operate the inverter if it has been physically damaged or if any components are missing.
3. Ngwaahịa gafereview
The Growatt SPH 5000TL3 BH UP is a hybrid inverter designed for photovoltaic systems, capable of managing solar power generation, battery storage, and grid interaction. It features a robust design and an intuitive OLED touchscreen for monitoring and control.

Figure 3.1: Growatt SPH 5000TL3 BH UP Hybrid Inverter with accompanying Smart Meter and Data Logger. The inverter is a white and black rectangular unit, while the smart meter is a white rectangular device and the data logger is a black cylindrical device.

Foto 3.2: N'ihu view of the Growatt SPH 5000TL3 BH UP Hybrid Inverter. The inverter features a prominent Growatt logo at the top, a black lower section with a green-lit OLED display and control buttons labeled 'ESC', 'OK', and arrow keys.
Ngwa:
- Inverter Unit: The main device responsible for converting DC power from solar panels to AC power for home use or grid export, and managing battery charging/discharging.
- OLED Touchscreen Display: Provides real-time operational data, system status, and allows for configuration adjustments.
- bọtịnụ njikwa: Used for navigating the menu and confirming selections on the OLED display.
- PV Input Terminals: Connections for solar panel strings.
- Ọnụ batrị: Connections for the battery bank.
- AC Output/Grid Connection: Connection for household loads and the utility grid.
- Ọdụ ụgbọ mmiri nkwukọrịta: For monitoring and external device connections (e.g., RS485, CAN/USB).
- Smart Meter (Optional/Included): For precise energy measurement and export limitation.
- Data Logger (Optional/Included): For remote monitoring and data collection.
4. Ntọala & nwụnye
Proper installation is crucial for the safe and efficient operation of your Growatt SPH 5000TL3 BH UP inverter. This section provides a general overview; refer to the detailed installation guide provided with your product for specific wiring diagrams and procedures.
4.1 Nhọrọ saịtị
- Choose a cool, dry, and well-ventilated location.
- Zere ikpughe ìhè anyanwụ kpọmkwem.
- Ensure adequate clearance around the inverter for heat dissipation.
- Mount on a sturdy, non-flammable surface.
- The inverter is designed for indoor photovoltaic installations in residential settings.
4.2 Ịkwanye ihe ntụgharị
Securely mount the inverter to a wall using appropriate mounting brackets and hardware. Ensure it is level and firmly attached.
4.3 Njikọ eletrik
All electrical wiring must be performed by a certified electrician in accordance with local and national electrical codes.
- PV Input Connection: Connect the DC cables from your solar panels to the PV input terminals. Ensure correct polarity.
- Njikọ batrị: Connect the battery cables to the battery terminals. Observe correct polarity and ensure the battery voltage is within the specified range (100-550 V).
- AC Output/Grid Connection: Connect the AC output to your household electrical panel and the utility grid. This inverter supports 100% three-phase unbalanced output.
- Nda ala: Ensure the inverter chassis is properly grounded.
- Njikọ njikọ: Connect the smart meter and data logger (if included) to the appropriate communication ports for monitoring and intelligent power export limitation.
5. Ntuziaka ọrụ
Once installed and all connections are verified, you can power on your Growatt SPH 5000TL3 BH UP inverter.
5.1 Na-agbanye ike
- Ensure all DC and AC breakers are in the OFF position.
- Turn on the DC disconnect switch for the solar panels.
- Turn on the battery disconnect switch.
- Turn on the AC breaker for the inverter output.
- The inverter will perform a self-test and then begin operation.
5.2 OLED Touchscreen Display
The OLED touchscreen provides real-time information and allows for system configuration. Use the 'ESC', 'OK', and arrow buttons to navigate the menus.

Ọgụgụ 5.1: N'akuku view of the Growatt SPH 5000TL3 BH UP Hybrid Inverter, highlighting the OLED display and control buttons. The display shows "Hybrid" and "Normal" status.
Common Display Information:
- Ike PV (W)
- Battery State of Charge (SOC %)
- Load Power (W)
- Grid Power (W) - import/export
- System Status (e.g., Normal, Fault, Standby)
- Daily/Total Energy Generation (kWh)
5.3 Ụdị usoro
The inverter operates in various modes to optimize energy flow, including self-consumption, grid-tied with export, and off-grid (UPS function).
- Njiri Onwe Onye: Prioritizes using solar power for household loads, then charging batteries, and finally exporting excess to the grid.
- Backup Mode (UPS Function): In case of grid failure, the inverter can provide power from the battery to critical loads with a 10ms transition time.
- Export Limitation: The intelligent phase-level power export limitation feature ensures compliance with local grid regulations.
6. Nlekọta
Regular maintenance ensures the longevity and optimal performance of your Growatt inverter. Always disconnect all power sources before performing any maintenance.
- Nyocha oge: Visually inspect the inverter and all connections for any signs of damage, corrosion, or loose wiring at least once every six months.
- Nhicha: Keep the inverter's ventilation openings clear of dust and debris to ensure proper airflow and cooling. Use a soft, dry cloth for cleaning the exterior. Do not use liquid cleaners.
- Mmelite femụwe: Check the Growatt website or contact support for available firmware updates to ensure your inverter has the latest features and bug fixes.
- Ahụike batrị: If connected to a battery system, monitor battery health and perform maintenance as recommended by the battery manufacturer.
7. Nchọpụta nsogbu
This section provides solutions to common issues you might encounter. For problems not listed here or if issues persist, contact Growatt technical support.
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Inverter not powering on | No AC input, DC input, or battery connection; tripped breaker. | Check all breakers (AC, DC, battery). Verify all connections are secure. Ensure sufficient PV voltage and battery charge. |
| Mpụta ike dị ala | Insufficient solar irradiance; dirty PV panels; shading; PV string issue. | Check weather conditions. Clean PV panels. Remove any shading. Inspect PV string connections and voltage. |
| Koodu mperi na ngosi | Internal fault; grid issue; over-temperature. | Note the error code and refer to the detailed error code list in the full manual. Ensure proper ventilation. If persistent, contact support. |
| No grid export | Export limitation enabled; grid connection issue; smart meter fault. | Check export limitation settings on the display. Verify grid connection. Check smart meter status and connections. |
8. Nkọwapụta
The following table outlines the key technical specifications for the Growatt SPH 5000TL3 BH UP Hybrid Inverter.

Figure 8.1: Detailed technical specifications table for the Growatt SPH 5000TL3 BH UP inverter, showing various electrical and physical parameters.
| Njirimara | Nkọwa |
|---|---|
| Ụdị | GROWATT |
| Aha Nlereanya | SPH 5000TL3 BH UP |
| Nọmba Nlereanya ihe | 20712 |
| Onye nrụpụta | Growatt |
| Eji ngwaahịa akwadoro | Solar power generation for domestic use or self-consumption |
| Isi Iyi Ike | Ike anyanwụ |
| Ike mmepụta | 7500 Watts (Max PV Power) |
| Ịrụ ọrụ | 97.2% |
| Ụdị ngosi | Touch (OLED) |
| Peak Output Power (watts) | 7500 |
| Electrical Output Waveform | Okpokoro nke Sine |
| Batrị Voltage Oke | 100-550 V |
| UPS Transition Time | 10 ms |
| Ụbọchị mbụ dị na Amazon.com.be | Nọvemba 20, 2023 |
| Nnweta akụkụ mapụtara | Ozi adịghị |
| Ekwadoro mmelite ngwanrọ ruo | Ozi adịghị |
9. Akwụkwọ ikike & Nkwado
9.1 Ozi akwụkwọ ikike
The Growatt SPH 5000TL3 BH UP Hybrid Inverter typically comes with a 10-afọ akwụkwọ ikike. Please refer to your purchase documentation or contact your supplier for specific warranty terms and conditions, as these may vary by region and distributor.
9.2 Nkwado nka na ụzụ
For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact Growatt customer support or your authorized Growatt dealer. Have your inverter's model number (SPH 5000TL3 BH UP) and serial number ready when contacting support.
You can find more information and support resources on the official Growatt websaịtị: www.growatt.com