1. Okwu mmalite
Thank you for choosing the Rebel POWER-1000 Pure Sine Wave UPS Inverter. This device is designed to provide stable and safe emergency power for various applications, including central heating furnaces, heat pumps, refrigerators, and other RTV/AGD systems. It features a pure sine wave output, ensuring compatibility with sensitive electronic and inductive loads, and offers three operating modes: emergency power supply (UPS), rectifier (charger), and inverter.
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your POWER-1000 inverter. Please read it thoroughly before use and retain it for future reference.
2. Ntuziaka nchekwa
Na-edebe nchekwa nchekwa ndị a mgbe niile iji gbochie mmerụ ahụ ma ọ bụ mebie ngwaọrụ:
- Nchekwa Eletriki: Ensure the device is connected to a properly grounded power outlet. Do not open the casing; enweghị akụkụ ndị ọrụ na-arụ ọrụ n'ime. Kpọtụrụ ndị ọrụ ruru eru ọrụ niile.
- Njikọ batrị: Connect the battery with correct polarity (red to positive, black to negative). Incorrect connection can cause severe damage to the inverter and battery. Use a 12V DC battery with a capacity between 50-200 Ah (55 Ah suggested).
- Igwe ikuku: Ensure adequate ventilation around the unit. Do not block the fan or ventilation openings. Overheating can lead to device malfunction or damage.
- gburugburu: Operate the device within the specified temperature range of 0 - 40°C and humidity of 10 - 90%. Avoid direct sunlight, moisture, dust, and corrosive environments.
- Nchekwa ibu ibu: Do not exceed the rated power of 700 W. The device is equipped with overload protection, but continuous overloading can shorten its lifespan.
- Liquid Contact: Keep the device away from liquids. In case of accidental liquid contact, immediately disconnect power and consult a service technician.
- Ụmụaka na anụ ụlọ: Debe ngwaọrụ ahụ ka ụmụaka na anụ ụlọ ghara iru.
3. Ngwa ngwaahịa
Familiarize yourself with the main components of your Rebel POWER-1000 UPS Inverter:

Onyonyo 3.1: Ogwe ihu
This image displays the front of the Rebel POWER-1000 inverter, featuring the LED display which shows operational status, battery charge, and load level. Below the display is the main ON/OFF switch.

Foto nke 3.2: Ogwe azụ dị n'eluview
This image shows the rear panel of the inverter. Visible components include the cooling fan, circuit breaker, two output sockets, battery connection terminals (red and black cables), and the AC input socket.
Figure 3.3: Rear Panel Connections Detail
A nso view of the rear panel, highlighting the 'OUTPUT' sockets for connecting appliances, the 'BATTERY +12V' terminals for external battery connection, the 'AC INPUT 230V' for mains power, and the 'CIRCUIT BREAKER' for protection.
Isi ihe:
- Ikanam Display: Provides real-time information on operating status, battery charge level, and load level.
- Main ON/OFF Switch: Controls the power to the inverter.
- Sockets mmepụta AC: Two 230V AC sockets for connecting your devices.
- Battery Terminals (12V DC): Connect to an external 12V DC battery. Ensure correct polarity.
- AC Input (230V): Connects the inverter to the mains power supply for charging the battery and providing power in UPS mode.
- Onye ofufe jụrụ oyi: Dissipates heat generated during operation.
- Circuit emebi: Provides protection against overcurrent.
4. Nhazi
Follow these steps to set up your Rebel POWER-1000 UPS Inverter:
- Iwepu: Carefully remove the inverter from its packaging. Inspect for any signs of damage.
- Nkwanye: Place the inverter on a stable, flat surface in a well-ventilated area, away from direct sunlight, heat sources, and moisture. Ensure sufficient space around the unit for airflow.
- Njikọ batrị:
- Ensure the inverter is switched OFF.
- Jikọọ uhie eriri batrị na nti (+) njedebe nke batrị DC 12V gị.
- Jikọọ nwa eriri batrị na adịghị mma (-) njedebe nke batrị DC 12V gị.
- Tighten all connections securely to prevent arcing.
- Njikọ AC Main: Plug the inverter's AC input cable into a standard 230V AC wall outlet.
- Njikọ ngwaọrụ: Plug the devices you wish to power into the 230V AC output sockets on the rear of the inverter. Ensure the total power consumption of connected devices does not exceed 700 W.
5. Ntuziaka ọrụ
The Rebel POWER-1000 operates in three main modes:
- UPS Mode (Emergency Power Supply): When connected to mains power, the inverter charges the external battery and simultaneously supplies power to connected devices. In case of a power outage, it automatically switches to battery power within <4 ms, providing uninterrupted power.
- Rectifier Mode (Battery Charger): When connected to mains power without any load, the inverter functions as a battery charger, replenishing the external battery.
- Ụdị ntụgharị: When not connected to mains power, the inverter converts 12V DC battery power into 230V AC pure sine wave power for your connected devices.
Starting the Inverter:
- Ensure all connections (battery, AC input, loads) are secure.
- Press the main ON/OFF switch on the front panel. The LED display will illuminate, indicating the current operating status, battery charge, and load level.
- The inverter will automatically select the appropriate operating mode based on the presence of mains power and connected loads.
LED Display Information:
The clear LED display provides crucial information:
- Ntinye Voltage: Shows the incoming AC voltage from the mains.
- Mmepụta Voltage: Displays the 230V AC output voltage.
- Batrị Voltage: Na-egosi voltage of the connected 12V battery.
- Ọkwa ibu: Na-egosi pasentịtage of the inverter's capacity being used by connected devices.
- Ọnọdụ ọrụ: Icons or indicators for mains power, battery power, charging, and fault conditions.
6. Nlekọta
Mmezi oge niile na-eme ka arụmọrụ kachasị mma na ogologo ndụ nke inverter gị dịgide:
- Nhicha: Periodically clean the exterior of the inverter with a soft, dry cloth. Ensure the cooling fan and ventilation openings are free from dust and debris. Do not use liquid cleaners.
- Nyocha batrị: Regularly check battery terminals for corrosion and ensure connections are tight. If using a lead-acid battery, check electrolyte levels if applicable and top up with distilled water as needed (refer to battery manufacturer's instructions).
- Igwe ikuku: Always ensure the inverter has adequate ventilation. Do not place objects on top of the unit or block its air vents.
- Nchekwa: If storing the inverter for an extended period, disconnect it from both mains power and the battery. Store in a cool, dry place. For optimal battery health, fully charge the battery before storage and recharge it every 3-6 months.
7. Nchọpụta nsogbu
If you encounter issues with your Rebel POWER-1000, refer to the following table:
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Inverter anaghị agbanyụ | No battery connected or battery discharged; Main switch off; Blown circuit breaker. | Connect a charged battery; Turn on the main switch; Check and reset the circuit breaker on the rear panel. |
| Enweghị mmepụta AC | Overload; Short circuit; Battery low; Inverter fault. | Reduce connected load; Check for short circuits in connected devices; Recharge or replace battery; If problem persists, contact support. |
| Batrị anaghị achaji | AC input not connected; AC input voltage too low/high; Battery fault. | Ensure AC input cable is securely plugged in; Check mains voltage; Test battery or replace if faulty. |
| Overload warning on display | Total power of connected devices exceeds 700 W. | Disconnect some devices to reduce the load below 700 W. |
| Unit is unusually hot | Blocked ventilation; Excessive load; High ambient temperature. | Ensure vents are clear; Reduce load; Move unit to a cooler environment. |
If the problem persists after attempting these solutions, please contact Rebel customer support or your retailer.
8. Nkọwapụta
Technical specifications for the Rebel POWER-1000 UPS Inverter (Model RB-4003):
| Njirimara | Nkọwapụta |
|---|---|
| Enyere ike | 700 W (1000 VA) |
| Ụdị batrị | 12 V DC |
| Oke batrị Voltage | 15 V DC |
| Ntinye Voltage Oke | 190 - 260 V AC |
| Ugboro ntinye | 45-60 Hz |
| Mmepụta Voltage (AC) | 230 V AC +/-5% (Inverter: 230 V AC +/-3%) |
| Ugboro mmepụta | 50/60 Hz +/- 0.5 Hz |
| Mmepụta Waveform | Okpokoro nke Sine |
| Mmepụta arụmọrụ | >= 85% (DC to AC) |
| Ịchaji batrị ugbu a | Oke. 10 A |
| Ike batrị atụnyere | 50-200 Ah (suggested: 55 Ah) |
| Oge Njikere echere | 4-14 hours (dependent on battery capacity) |
| Oge mgbanwe | =<4 ms |
| Nchedo | Overload, Short Circuit, Over/Under Voltage |
| Okpomọkụ na-arụ ọrụ | 0 - 40°C |
| Iru mmiri na-arụ ọrụ | 10 - 90% |
| Akụkụ (L x W x H) | 336 x 143 x 178 mm |
| Ibu | 4.3 n'arọ |
9. Akwụkwọ ikike na nkwado
The Rebel POWER-1000 UPS Inverter is manufactured by Rebel. For warranty information, please refer to the warranty card included with your product or consult the retailer from whom you purchased the device. Keep your proof of purchase for warranty claims.
For technical support or service inquiries, please contact your local Rebel distributor or the point of purchase. Ensure you have your product model (RB-4003) and serial number (if applicable) ready when contacting support.