Rebel RB-4003

Rebel POWER-1000 Pure Sine Wave UPS Inverter User Manual

Model: RB-4003 | Brand: Rebel

1. Okwu mmalite

Thank you for choosing the Rebel POWER-1000 Pure Sine Wave UPS Inverter. This device is designed to provide stable and safe emergency power for various applications, including central heating furnaces, heat pumps, refrigerators, and other RTV/AGD systems. It features a pure sine wave output, ensuring compatibility with sensitive electronic and inductive loads, and offers three operating modes: emergency power supply (UPS), rectifier (charger), and inverter.

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your POWER-1000 inverter. Please read it thoroughly before use and retain it for future reference.

2. Ntuziaka nchekwa

Na-edebe nchekwa nchekwa ndị a mgbe niile iji gbochie mmerụ ahụ ma ọ bụ mebie ngwaọrụ:

3. Ngwa ngwaahịa

Familiarize yourself with the main components of your Rebel POWER-1000 UPS Inverter:

N'ihu view of Rebel POWER-1000 UPS Inverter showing the LED display and main power switch.

Onyonyo 3.1: Ogwe ihu
This image displays the front of the Rebel POWER-1000 inverter, featuring the LED display which shows operational status, battery charge, and load level. Below the display is the main ON/OFF switch.

N'azụ view of Rebel POWER-1000 UPS Inverter with battery cables, AC input, and output sockets.

Foto nke 3.2: Ogwe azụ dị n'eluview
This image shows the rear panel of the inverter. Visible components include the cooling fan, circuit breaker, two output sockets, battery connection terminals (red and black cables), and the AC input socket.

Close-up of the rear panel connections on Rebel POWER-1000 UPS Inverter.

Figure 3.3: Rear Panel Connections Detail
A nso view of the rear panel, highlighting the 'OUTPUT' sockets for connecting appliances, the 'BATTERY +12V' terminals for external battery connection, the 'AC INPUT 230V' for mains power, and the 'CIRCUIT BREAKER' for protection.

Isi ihe:

4. Nhazi

Follow these steps to set up your Rebel POWER-1000 UPS Inverter:

  1. Iwepu: Carefully remove the inverter from its packaging. Inspect for any signs of damage.
  2. Nkwanye: Place the inverter on a stable, flat surface in a well-ventilated area, away from direct sunlight, heat sources, and moisture. Ensure sufficient space around the unit for airflow.
  3. Njikọ batrị:
    • Ensure the inverter is switched OFF.
    • Jikọọ uhie eriri batrị na nti (+) njedebe nke batrị DC 12V gị.
    • Jikọọ nwa eriri batrị na adịghị mma (-) njedebe nke batrị DC 12V gị.
    • Tighten all connections securely to prevent arcing.
  4. Njikọ AC Main: Plug the inverter's AC input cable into a standard 230V AC wall outlet.
  5. Njikọ ngwaọrụ: Plug the devices you wish to power into the 230V AC output sockets on the rear of the inverter. Ensure the total power consumption of connected devices does not exceed 700 W.

5. Ntuziaka ọrụ

The Rebel POWER-1000 operates in three main modes:

Starting the Inverter:

  1. Ensure all connections (battery, AC input, loads) are secure.
  2. Press the main ON/OFF switch on the front panel. The LED display will illuminate, indicating the current operating status, battery charge, and load level.
  3. The inverter will automatically select the appropriate operating mode based on the presence of mains power and connected loads.

LED Display Information:

The clear LED display provides crucial information:

6. Nlekọta

Mmezi oge niile na-eme ka arụmọrụ kachasị mma na ogologo ndụ nke inverter gị dịgide:

7. Nchọpụta nsogbu

If you encounter issues with your Rebel POWER-1000, refer to the following table:

NsogbuIhe nwere ike imeNgwọta
Inverter anaghị agbanyụNo battery connected or battery discharged; Main switch off; Blown circuit breaker.Connect a charged battery; Turn on the main switch; Check and reset the circuit breaker on the rear panel.
Enweghị mmepụta ACOverload; Short circuit; Battery low; Inverter fault.Reduce connected load; Check for short circuits in connected devices; Recharge or replace battery; If problem persists, contact support.
Batrị anaghị achajiAC input not connected; AC input voltage too low/high; Battery fault.Ensure AC input cable is securely plugged in; Check mains voltage; Test battery or replace if faulty.
Overload warning on displayTotal power of connected devices exceeds 700 W.Disconnect some devices to reduce the load below 700 W.
Unit is unusually hotBlocked ventilation; Excessive load; High ambient temperature.Ensure vents are clear; Reduce load; Move unit to a cooler environment.

If the problem persists after attempting these solutions, please contact Rebel customer support or your retailer.

8. Nkọwapụta

Technical specifications for the Rebel POWER-1000 UPS Inverter (Model RB-4003):

NjirimaraNkọwapụta
Enyere ike700 W (1000 VA)
Ụdị batrị12 V DC
Oke batrị Voltage15 V DC
Ntinye Voltage Oke190 - 260 V AC
Ugboro ntinye45-60 Hz
Mmepụta Voltage (AC)230 V AC +/-5% (Inverter: 230 V AC +/-3%)
Ugboro mmepụta50/60 Hz +/- 0.5 Hz
Mmepụta WaveformOkpokoro nke Sine
Mmepụta arụmọrụ>= 85% (DC to AC)
Ịchaji batrị ugbu aOke. 10 A
Ike batrị atụnyere50-200 Ah (suggested: 55 Ah)
Oge Njikere echere4-14 hours (dependent on battery capacity)
Oge mgbanwe=<4 ms
NchedoOverload, Short Circuit, Over/Under Voltage
Okpomọkụ na-arụ ọrụ0 - 40°C
Iru mmiri na-arụ ọrụ10 - 90%
Akụkụ (L x W x H)336 x 143 x 178 mm
Ibu4.3 n'arọ

9. Akwụkwọ ikike na nkwado

The Rebel POWER-1000 UPS Inverter is manufactured by Rebel. For warranty information, please refer to the warranty card included with your product or consult the retailer from whom you purchased the device. Keep your proof of purchase for warranty claims.

For technical support or service inquiries, please contact your local Rebel distributor or the point of purchase. Ensure you have your product model (RB-4003) and serial number (if applicable) ready when contacting support.