Hoymiles HMS-2000-4T

Ntuziaka Onye Ọrụ Microinverter Hoymiles HMS-2000-4T

For Four Solar Modules, 2000 Watt with Optional WiFi

1. Okwu mmalite

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Hoymiles HMS-2000-4T Microinverter. The HMS-2000-4T is a high-performance microinverter designed for balcony power plants and rooftop solar systems, capable of handling up to four solar panels with a total nominal output of 2000 VA.

Key features include MPPT voltage regulation for optimal energy harvesting, integrated protection functions, an IP67 enclosure rating for durability, and a 12-year product warranty. Please read this manual thoroughly before installation and operation.

2. Ntuziaka nchekwa

Na-edebe ihe nchekwa nchekwa ndị a mgbe niile iji gbochie mmerụ ahụ na mmebi nke akụrụngwa:

3. Ngwaahịa gafereview

The Hoymiles HMS-2000-4T Microinverter is designed to convert direct current (DC) from solar panels into alternating current (AC) for grid injection. It features four independent Maximum Power Point Tracking (MPPT) channels, allowing each connected solar panel to operate at its optimal power output, even under varying conditions like shading or dust accumulation.

Akụkụ ndị bụ isi:

Hoymiles HMS-2000-4T Microinverter

Foto 1: N'ihu view of the Hoymiles HMS-2000-4T Microinverter, showing its finned housing for heat dissipation and connection ports for solar panels and AC output.

4. Ntọala na nwụnye

The HMS-2000-4T is designed for straightforward installation. Follow these general steps:

  1. Ịkwanye: Securely mount the microinverter to the solar panel racking system or a suitable surface. Ensure adequate ventilation around the unit for heat dissipation.
  2. Njikọ DC: Connect the DC cables from each solar panel to the corresponding input ports on the microinverter. Ensure correct polarity (+ to + and - to -). The microinverter supports up to four solar panels.
  3. Njikọ AC: Connect the AC output cable from the microinverter to your home's electrical grid or a dedicated balcony power plant connection point. This typically involves a grid connection cable (not included) and may require an electrician for final connection to the main electrical panel.
  4. Nda ala: Ensure the microinverter is properly grounded according to local electrical codes.
  5. Monitoring (Optional): For monitoring performance, a Hoymiles Data Transfer Unit (DTU) is required (sold separately). Connect the DTU to the microinverter system to enable data collection and remote monitoring via the Hoymiles app or web portal.
  6. Ike Na: Once all connections are secure and verified, switch on the AC breaker to energize the microinverter. The unit will begin its startup sequence and, if conditions are suitable, start producing power.
Hoymiles Microinverter Datasheet Overview

Figure 2: Datasheet overview highlighting key features such as 4-in-1 design, independent MPPT, and easy installation. This image provides a visual summary of the product's benefits and capabilities.

5. Ntuziaka ọrụ

The Hoymiles HMS-2000-4T Microinverter operates automatically once properly installed and connected to the grid. It will begin converting DC power from your solar panels into AC power whenever sufficient sunlight is available.

6. Nlekọta

The Hoymiles HMS-2000-4T Microinverter is designed for minimal maintenance due to its robust construction and IP67 protection rating. However, periodic checks are recommended:

7. Nchọpụta nsogbu

If you encounter issues with your Hoymiles HMS-2000-4T Microinverter, refer to the following common troubleshooting steps:

For persistent issues, please contact Hoymiles customer support or a certified service technician.

8. Nkọwapụta

Detailed technical specifications for the Hoymiles HMS-2000-4T Microinverter are provided below. These specifications are crucial for proper system design and installation.

Hoymiles HMS-2000-4T Product Label with Specifications

Figure 3: Product label displaying key electrical and environmental specifications for the HMS-2000-4T Microinverter.

Hoymiles HMS-2000-4T Detailed Technical Data Table

Figure 4: Detailed technical data table for the Hoymiles HMS-2000-4T, including electrical characteristics, efficiency, mechanical data, and communication protocols.

Nkọwa n'ozuzu:

NjirimaraUru
Aha NlereanyaHMS-2000
Nọmba nlereanyaHMS-2000-4T
ỤdịHoymiles
Isi Iyi IkeIke anyanwụ
Wattage2000 Watt
Ngwa akwadoroỤlọ
Akụkụ ngwugwu53.5 x 27.9 x 5.2 cm
Ibu4.7 kilogram
Mbụ DịỌktoba 18, 2023

Electrical Specifications (DC Input):

NjirimaraUru
Max. Ntinye Voltage65V dc
MPPT Voltage Oke16-60V dc
Mmalite Voltage22V dc
Oke. Ntinye na-aga n'ihu ugbu a4 × 16 A d.c.
Oke. Ntinye Mkpirisi sekit ugbu a4 × 25 A d.c.
Ọnụọgụ nke MPPT4
Ọnụọgụ ntinye kwa MPPT1

Electrical Specifications (AC Output):

NjirimaraUru
Oke. Ike Mbupute na-aga n'ihu2000 VA
Oke. Mmepụta na-aga n'ihu ugbu a8.70 Ac
Elu ọnụ mmepụta Voltage230/240 V a.c.
Ugboro mmepụta aha50/60 Hz
Ihe nrụpụta ike>0.99 (default)
Arụmọrụ Mgbanwe Kasị Elu96.5%
arụmọrụ kacha elu CEC96.5%
MPPT Nominal Efficiency99.8%
Oriri Ike Abali<50mW

Mechanical & Environmental Specifications:

NjirimaraUru
Oke okpomọkụ gburugburu-40°C ruo +65°C
Akụkụ (W x H x D)331 x 218 x 40.6 mm
Ibu4.7 n'arọ
Klas nchekwaIP67 (NEMA 6)
Na-ajụ oyiNatural Convection - No internal fan
Ụdị icheGalvanically Isolated Transformer
NkwukọrịtaSub-1G
nlekota oruS-Miles Cloud (via DTU)
Mfefetage ngalabaPV-II, Mains-III
Klas nchekwaI
ogo mmetọPD3

9. Akwụkwọ ikike

The Hoymiles HMS-2000-4T Microinverter comes with a Akwụkwọ ikike ngwaahịa afọ 12. This warranty covers defects in materials and workmanship under normal use and service conditions. Please retain your proof of purchase for warranty claims. For detailed warranty terms and conditions, refer to the official Hoymiles warranty statement or contact customer support.

10. Nkwado na Akụrụngwa Ndị Ọzọ

For further assistance, technical support, or to access additional resources, please use the following:

Akwụkwọ ndị emetụtara - HMS-2000-4T

Tupuview Hoymiles HMS-2000-4T Series Microinverter Ntuziaka nwụnye ngwa ngwa
Ntuziaka ntinye nzọụkwụ site na nzọụkwụ maka Hoymiles HMS-2000-4T usoro anyanwụ microinverters. Na-ekpuchi njirimara ngwa, ntinye microinverter, mgbakọ USB ụgbọ ala AC, njikọ sistemu, njikọta modul PV, usoro ịgbalite ọkụ, na nleba anya nrụnye.
Tupuview Hoymiles HMS-1600/1800/2000 Single-phase Microinverter User Manual
Comprehensive user manual for Hoymiles HMS-1600-4T, HMS-1800-4T, and HMS-2000-4T single-phase microinverters. Covers installation, operation, troubleshooting, and technical specifications for efficient solar energy conversion.
Tupuview Hoymiles Single-phase Microinverter User Manual (HMS-1600/1800/2000-4T-NA)
This user manual provides comprehensive instructions for installing, operating, and maintaining Hoymiles HMS-1600-4T-NA, HMS-1800-4T-NA, and HMS-2000-4T-NA single-phase microinverters. Learn about safety precautions, technical specifications, troubleshooting, and grid support features for your solar power system.
Tupuview Hoymiles HMS-1600/1800/2000-4T-NA Single-phase Microinverter User Manual
Comprehensive user manual for Hoymiles HMS-1600-4T-NA, HMS-1800-4T-NA, and HMS-2000-4T-NA single-phase microinverters. Covers installation, operation, troubleshooting, and technical specifications for efficient solar energy conversion.
Tupuview Hoymiles Single-Phase Microinverter User Manual
Comprehensive user manual for Hoymiles single-phase microinverters, including models HMS-1600-4T-NA, HMS-1800-4T-NA, and HMS-2000-4T-NA. Covers installation, operation, troubleshooting, and technical specifications.
Tupuview Manual do Usuário: Microinversor Monofásico Hoymiles HMS-1600/1800/2000-4T
Este manual do usuário fornece instruções detalhadas para a instalação, operação e manutenção dos microinversores monofásicos Hoymiles modelos HMS-1600-4T, HMS-1800-4T e HMS-2000-4T. Saiba mais sobre a tecnologia, segurança e solução de problemas para sistemas fotovoltaicos.