1. Okwu mmalite
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the AKO AKO-15692 Three-Phase PROPlus Basic Electronic Control Panel with Defrost 10200W. Please read this manual thoroughly before installation and operation.

Foto 1: N'ihu view of the AKO AKO-15692 control panel. This image displays the front of the AKO AKO-15692 control panel. On the left, a digital display shows '-19.4' with 'ECO' and defrost indicators. Below the display are navigation buttons (up, down, set, escape, power, question mark, light). The right side features a transparent hinged cover, revealing internal circuit breakers and a rotary switch.
2. Ozi nchekwa
Na-agbaso ihe ndị a dị mkpa mgbe niile iji gbochie mmerụ ahụ na mmebi nke ngwaọrụ ahụ:
- Naanị ndị ọrụ ruru eru ga-arụrịrị nrụnye na nrụzi.
- Disconnect power before performing any work on the control panel.
- Gbaa mbọ hụ na ntọ ala kwesịrị ekwesị iji gbochie ujo eletrik.
- Do not expose the unit to moisture or extreme temperatures outside its operating range.
- Jide n'aka na njikọ niile dị mma ma ziri ezi tupu i jiri ike.
3. Ngwaahịa gafereview
The AKO-15692 is a three-phase electronic control panel designed for refrigeration systems requiring defrost management. It integrates control, protection, and monitoring functions for optimal performance and energy efficiency.
Akụkụ ndị bụ isi:
- Three-phase power compatibility (up to 10200W).
- Integrated defrost control.
- Digital display for temperature and status.
- User-friendly control interface.
- Robust enclosure for industrial environments.
4. Ntọala na nwụnye
4.1 Nwepu
Carefully unpack the control panel and inspect it for any signs of damage. Retain the packaging materials for future transport or storage.
4.2 Na-arịgo
The unit is designed for screw-mounted installation. Choose a dry, well-ventilated location away from direct heat sources or excessive vibration. Ensure sufficient space for wiring and ventilation.
- Mark the mounting points on the wall using the panel's dimensions.
- Gwuo oghere kwesịrị ekwesị ma tinye plọg mgbidi ma ọ bụrụ na ọ dị mkpa.
- Secure the control panel to the wall using suitable screws.
4.3 Njikọ eletrik
All electrical connections must comply with local and national electrical codes. Refer to the wiring diagram provided inside the panel cover for specific connections.
- Ịnye ọkụ: Connect the three-phase power supply to the designated terminals.
- Compressor: Connect the compressor load to the appropriate output terminals.
- Defrost Heaters: Connect defrost heaters to their dedicated output terminals.
- Ihe mmetụta: Connect temperature sensors to the specified input terminals.
- Nda ala: Ensure all grounding connections are properly made.
Warning: Incorrect wiring can lead to severe damage or electrical shock. Consult a qualified electrician if unsure.
5. Ntuziaka ọrụ
5.1 Gbanyụọ/ gbanyụọ
Pịa ⏻ (Power) button to turn the unit on or off. The digital display will illuminate upon power-on.
5.2 Ngosipụta na Nsoro ụzọ
The digital display shows the current temperature or system status. Use the following buttons for navigation and settings:
- WEP :TARA: Enter/confirm settings.
- ▲ (Up): Increase values or navigate up.
- ▼ (Down): Decrease values or navigate down.
- ESC: Exit menu or cancel operation.
- ?: Access help or information.
- ☀︎ (Light): Control internal light (if applicable) or display brightness.
5.3 Ntọlite okpomọkụ
- Pịa SET button. The current setpoint will flash.
- Jiri ihe v or ▼ bọtịnụ iji dozie okpomọkụ achọrọ.
- Pịa SET again to confirm the new setpoint.
5.4 Mkpọpu okirikiri
The unit features automatic defrost control. Parameters such as defrost interval and duration can be configured through the settings menu. Consult the detailed programming section in the full manual for advanced configurations.
6. Nlekọta
Regular maintenance ensures optimal performance and longevity of the control panel.
6.1 Nhicha
- Kwupu ike tupu ihicha.
- Jiri nwayọ hichaa mpụta, damp akwa . Ejila ihe nchacha abrasive ma ọ bụ ihe mgbaze.
- Ensure no moisture enters the internal components.
6.2 Nyocha
Nyochaa ihe ndị a kwa oge:
- Wiring: Lelee maka waya ndị rụrụ arụ ma ọ bụ mebiri emebi.
- Ọnụ: Ensure all terminal connections are tight.
- Mkpuchi: Look for any signs of physical damage or corrosion.
- Igwe ikuku: Ensure ventilation openings are clear and unobstructed.
7. Nchọpụta nsogbu
This section addresses common issues. For more complex problems, contact technical support.
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Ogwe anaghị agba ọkụ. | No power supply; Blown fuse/tripped breaker. | Check main power supply; Inspect fuses/breakers and reset if necessary. |
| Ọgụgụ okpomọkụ ezighi ezi. | Faulty sensor; Sensor incorrectly placed. | Check sensor connections; Verify sensor placement; Replace sensor if faulty. |
| Defrost not initiating. | Incorrect defrost settings; Defrost heater fault. | Review defrost parameters in settings; Check defrost heater and wiring. |
8. Nkọwapụta
| Njirimara | Nkọwa |
|---|---|
| Nlereanya | AKO-15692 |
| Ụdị | AKO |
| Ogo ike | 10200W |
| Usoro | Usoro atọ |
| Ụdị nwụnye | Edokwasara skru |
| Ọrụ Ntugharị | Ejikọtara |
9. Akwụkwọ ikike na nkwado
9.1 Ozi akwụkwọ ikike
AKO products are covered by a standard manufacturer's warranty. Please refer to the warranty card included with your purchase or visit the official AKO websaịtị maka nkọwa zuru ezu usoro na ọnọdụ.
9.2 Nkwado nka na ụzụ
For technical assistance, spare parts, or service inquiries, please contact AKO customer support. Have your model number (AKO-15692) and purchase date ready when contacting support.
Contact information (e.g., phone, email, website) can typically be found on the product packaging or the official AKO websaịtị.