The Moretti DM592S is an automatic digital blood pressure monitor designed for accurate and rapid measurement of systolic pressure, diastolic pressure, and pulse rate. It features an innovative design with a large 4.8-inch (6.9 × 10.2 cm) backlit LCD screen that simultaneously displays readings, date/time, and irregular heartbeat detection (IHD). This device is equipped with memory functions for two users, storing up to 60 measurements per user, and can calculate the average of the last three readings. An optional USB interface allows for PC connectivity.
2. Ozi nchekwa
Please read all instructions carefully before using this device. Improper use may result in inaccurate readings or device damage. This device is intended for adult use only. Consult your physician for interpretation of blood pressure readings. Self-diagnosis and treatment based on measurement results can be dangerous.
- Ejila ngwaọrụ a mee ihe maka ụmụ ọhụrụ, ụmụaka, ma ọ bụ ndị na-enweghị ike ikwupụta nkwenye ha.
- Do not use this device for purposes other than measuring blood pressure.
- Keep the device and cuff away from water and moisture.
- Zere oghere electromagnetic siri ike yana ìhè anyanwụ kpọmkwem.
- Etusala ma ọ bụ nwaa ịrụkwa ngwaọrụ ahụ.
- Chekwaa ngwaọrụ ahụ n'ebe dị ọcha, kpọrọ nkụ.
3. Ngwa ngwaahịa
The Moretti DM592S package typically includes:
- Moretti DM592S Blood Pressure Monitor Unit
- Arm Cuff (22-36 cm circumference) with Velcro closure
- Akwụkwọ ntuziaka onye ọrụ
- 4 x AA 1.5V Batteries (may be included or sold separately)
- Optional: AC Power Adapter (Code DR205), USB Cable, Software CD

This image displays the Moretti DM592S Automatic Digital Blood Pressure Monitor alongside its arm cuff. The monitor features a large LCD screen showing blood pressure readings (SYS 120, DIA 75 mmHg) and pulse rate (75 PUL/min). The cuff is labeled for the 'LEFT ARM' and indicates a size range of 22-36 cm (8.6-14.2 inch) with instructions for proper placement.
4. Nhazi
4.1 Ntinye batrị
- Mepee mkpuchi nke batrị dị n'azụ ihe nlele ahụ.
- Insert four (4) AA 1.5V batteries, ensuring correct polarity (+/-).
- Mechie mkpuchi nke batrị batrị nke ọma.
- Alternatively, connect the optional AC power adapter (DR205) to the monitor and a power outlet (AC 220/230V 50Hz - DC 6.0V, 600mA).
4.2 Njikọ Cuff
- Insert the air tube connector from the cuff firmly into the air jack on the side of the monitor.
5. Ntuziaka ọrụ
5.1 Tupu Ntule
- Zere iri ihe, ịṅụ mmanya na-aba n'anya, ise siga, mgbatị ahụ, na ịsa ahụ maka nkeji 30 tupu ị tụọ ya.
- Zuru ike ma ọ dịkarịa ala nkeji 5 tupu ị tụọ nha.
- Nọdụ ala kwụ ọtọ na-akwado azụ gị na ụkwụ kwụ ọtọ n'ala.
- Tinye ogwe aka gị na tebụl ka cuff wee nọrọ n'ogo obi.
5.2 Itinye Ogwe aka
- Ensure the cuff is suitable for your arm circumference (22-36 cm).
- Mikpuo aka ekpe gị site na mkpọchi aka ekpe. Tubụ ikuku kwesịrị ịgbasa n'ime ogwe aka gị.
- Position the cuff so the bottom edge is approximately 1-2 cm (0.4-0.8 inch) above your elbow joint.
- Wrap the cuff snugly around your upper arm, securing it with the Velcro closure. Ensure it is not too tight or too loose.
- The "Main Artery" mark on the cuff should be aligned with your brachial artery (inner side of your arm).
5.3 Inyocha ihe
- Pịa Malite/Kwụsị button to turn on the monitor. The cuff will automatically inflate.
- Nọgide jụụ ma gbachi nkịtị n'oge a na-atụ ihe.
- Once the measurement is complete, the monitor will display your systolic pressure, diastolic pressure, and pulse rate.
- Pịa Malite/Kwụsị bọtịnụ ọzọ iji gbanyụọ ihe nlele ahụ, ma ọ bụghị ya, ọ ga-agbanyụ ozugbo mgbe oge adịghị arụ ọrụ gasịrị.
6. Ọrụ ebe nchekwa
The DM592S features memory storage for two users (User 1 and User 2), with 60 memories per user, totaling 120 memories. It also calculates the average of the last three measurements.
6.1 Selecting a User
The monitor has dedicated buttons for User 1 and User 2 (indicated by padlock icons). Press the respective user button to select the desired user profile before taking a measurement or reviewebe nchekwa.
6.2 Reviewna-echekwa nha
- With the monitor off, press the MEM bọtịnụ.
- The monitor will display the average of the last three measurements for the currently selected user.
- Pịa MEM bọtịnụ ugboro ugboro iji pịgharịa site na nha echekwara nke ọ bụla, site na nke kachasị ọhụrụ ruo nke kacha ochie.
7. PC Interface (Optional)
The Moretti DM592S offers the possibility to interface with a PC via a USB port. This functionality requires an optional software CD and USB cable. Please refer to the instructions provided with the optional software for detailed connection and data transfer procedures.
8. Nlekọta na nlekọta
- Nhicha: Wipe the monitor and cuff with a soft, dry cloth. If necessary, use a slightly damp cloth with mild soap, then wipe dry. Do not use abrasive cleaners or immerse the device in water.
- Nchekwa: Store the device and cuff in a clean, dry place, away from direct sunlight, extreme temperatures, and dust.
- Batrị: Wepu batrị ma ọ bụrụ na agaghị eji ngwaọrụ ahụ ogologo oge iji gbochie ntapu.
9. Nchọpụta nsogbu
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Ngwaọrụ anaghị agbanwu. | Batrị anwụọla ma ọ bụ tinye na ezighi ezi. | Replace batteries with new ones, ensuring correct polarity. Check AC adapter connection if using. |
| Ọgụgụ na-ezighi ezi. | Improper cuff placement, movement during measurement, or speaking. | Ensure cuff is correctly applied and positioned. Remain still and silent during measurement. Rest for 5 minutes before measuring. |
| Cuff anaghị afụ ma ọ bụ na-afụ oke obere/oke. | Air tube disconnected or kinked. Cuff not properly secured. | Check that the air tube is securely connected to the monitor. Re-apply the cuff snugly. |
| Ozi mperi na ngosi. | Various internal errors or measurement issues. | Turn off the device, wait a few minutes, and try again. If the error persists, contact customer support. |
10. Nkọwapụta
| Ụdị: | DM592S |
| Ụzọ nha: | Oscillometric |
| Ngosipụta: | 4.8-inch (6.9 × 10.2 cm) Backlit LCD |
| Oke Nleta Nrụgide: | 0-300 mmHg |
| Pulse Measurement Range: | 30-180 kụrụ / nkeji |
| Ịdị mma nrụgide: | +/- 3 mmHg |
| Ịdị mma Pulse: | +/- 5% |
| Cuff Circumference: | 22-36 cm |
| Ebe nchekwa: | 2 users, 60 memories/user (total 120) |
| Ịnye ọkụ: | 4 x AA 1.5V batteries or optional AC adapter (DR205: AC 220/230V 50Hz - DC 6.0V, 600mA) |
| Akụkụ (L x W x H): | 16.4 x 11 x 6 cm |
| Ibu (na-enweghị batrị): | 430 g |
11. Akwụkwọ ikike na nkwado
Specific warranty details are not provided in this manual. Please refer to the warranty card included with your product or contact your point of purchase for warranty information. For technical support, service, or inquiries regarding your Moretti DM592S Blood Pressure Monitor, please contact the manufacturer or authorized distributor.
Manufacturer: Moretti Spa