Jebao ECP-180M

Jebao Jecod ECP-180M Smart Cross-Flow Pump Wave Maker User Manual

Model: ECP-180M

1. Okwu mmalite

This manual provides comprehensive instructions for the safe and efficient use of your Jebao Jecod ECP-180M Smart Cross-Flow Pump Wave Maker. Please read this manual thoroughly before installation and operation to ensure proper function and longevity of the product. Retain this manual for future reference.

The Jecod ECP-180M is a smart cross-flow pump designed for creating natural wave patterns and optimal water circulation in aquariums. It features Wi-Fi connectivity for control via a smartphone application and includes a manual LCD display controller.

Jecod ECP-180M Smart Cross-Flow Pump Wave Maker and its packaging

Image 1.1: The Jecod ECP-180M Smart Cross-Flow Pump Wave Maker and its retail packaging.

2. Ntuziaka nchekwa

WARNING: To avoid potential electric shock, special care should be taken when using aquarium equipment. Read and follow all safety instructions carefully.

  • Always disconnect all appliances from the electrical supply before placing hands into the water, performing maintenance, or handling the pump.
  • Ejila ngwa ọ bụla rụọ ọrụ ma ọ bụrụ na ọ nwere eriri ma ọ bụ plọg mebiri emebi, ma ọ bụ ọ bụrụ na ọ naghị arụ ọrụ ma ọ bụ tufuo ma ọ bụ mebie n'ụzọ ọ bụla.
  • To avoid the possibility of the appliance plug or receptacle getting wet, position the aquarium stand and tank to one side of a wall-mounted receptacle to prevent water from dripping onto the receptacle or plug. A 'drip loop' should be arranged for each cord connecting an aquarium appliance to a receptacle. The 'drip loop' is the part of the cord below the level of the receptacle, or the connector if an extension cord is used, to prevent water from traveling along the cord and coming into contact with the receptacle.
  • Never pull the cord to unplug the pump from the outlet. Grasp the plug and pull to disconnect.
  • Do not use the appliance for anything other than its intended use. The use of attachments not recommended or sold by the appliance manufacturer may cause an unsafe condition.
  • Awụnyela ma ọ bụ chekwaa ngwa ahụ ebe ọ ga-ekpuchi ihu igwe ma ọ bụ okpomọkụ n'okpuru oyi.
  • Ensure the pump is fully submerged in water during operation. Running the pump dry can cause damage.
  • Ngwa a bụ maka naanị ụlọ.

3. Ihe ngwugwu

Carefully unpack all components and inspect them for any damage. If any items are missing or damaged, please contact your retailer.

  • Jecod ECP-180M Cross-Flow Pump
  • Controller with LCD Display
  • Power Adapter (AC 100-240V, DC 24V)
  • Igwe Igwe Ọdụdọ
  • Akwụkwọ ntuziaka (akwụkwọ a)
All components of the Jecod ECP-180M pump system laid out

Image 3.1: All components included with the Jecod ECP-180M Smart Cross-Flow Pump Wave Maker.

4. Akụrụngwa Ngwaahịa

  • Njikwa smart: Wi-Fi connectivity for control via iOS and Android smartphone applications, alongside a manual LCD display controller.
  • Ọrụ dị jụụ: Utilizes SINE wave technology for ultra-quiet and stable performance.
  • Optimal Water Flow: Cross-wave single impeller structure ensures comprehensive water movement without dead spots.
  • Ojiji dị iche iche: Constructed without exposed copper elements, making it suitable for both marine and freshwater aquarium environments.
  • Ọnụego nfe dị elu: Maximum flow of 7925 GPH (Gallons Per Hour).

5. Nkọwapụta

NjirimaraNkọwapụta
NlereanyaECP-180M
Onye nrụpụtaJebao
Akụkụ (Pump)13.5" x 3.25" x 1.5"
Ntinye VoltageAC 100-240V, 50/60Hz
Mmepụta VoltageDC 24V
Oriri ike65W
Ọnụego nfe kachaIhe dị ka 7925 GPH
Ihe onwunwePolypropylene (PP), Ígwè anaghị agba nchara
Oke okpomọkụ mmiri35°C
Ngwa gụnyerePump, Controller, Power Adapter
Ibu Ibu4.46 pound
Agara nso view of the Jecod ECP-180M pump showing product label with specifications

Image 5.1: Close-up of the Jecod ECP-180M pump, displaying its product label and specifications.

6. Ntọala na nwụnye

6.1 Placement of the Pump

  1. Identify a suitable location within your aquarium for optimal water circulation. Cross-flow pumps are typically placed horizontally near the water surface.
  2. Ensure the pump is fully submerged and positioned away from sand beds to prevent debris intake.
  3. Use the provided mounting magnets to secure the pump to the aquarium glass. Place one magnet inside the tank, attached to the pump, and the corresponding magnet on the outside of the tank glass, aligning them to hold the pump firmly in place.
Jecod ECP-180M cross-flow pump, ready for installation

Image 6.1: The Jecod ECP-180M cross-flow pump, illustrating its design for aquarium placement.

6.2 Connecting the Controller and Power

  1. Connect the pump cable to the designated port on the controller.
  2. Jikọọ ihe nkwụnye ọkụ na njikwa.
  3. Plug the power adapter into a standard electrical outlet, ensuring a drip loop is formed to prevent water from reaching the outlet.
  4. The controller's LCD screen should illuminate, indicating power.

7. Ntuziaka ọrụ

7.1 Manual Controller Operation

The LCD display controller allows for direct adjustment of pump settings.

  • Bọtịnụ ụkpụrụ: Press to cycle through various wave modes (e.g., constant flow, pulse, random).
  • Speed/Flow Adjustment: Use the '+' and '-' buttons to increase or decrease the pump's flow rate or wave intensity.
  • Ụdị nri: A dedicated button may be present to temporarily pause the pump for feeding, typically for 10 minutes.
  • Refer to the controller's specific button labels and on-screen prompts for detailed mode selection and adjustment.

7.2 Wi-Fi App Control

The Jecod ECP-180M can be controlled via a smartphone application (iOS and Android).

  1. Download the official Jebao/Jecod app from your device's app store.
  2. Follow the in-app instructions to connect the controller to your home Wi-Fi network. This typically involves putting the controller into pairing mode and selecting your Wi-Fi network.
  3. Once connected, you can use the app to adjust modes, flow rates, set schedules, and access advanced features.

8. Nlekọta

Regular maintenance is essential for the optimal performance and longevity of your pump.

8.1 Nhicha oge niile

  1. Kwụpụ ike: Kwapụ pampụ ahụ mgbe niile na ebe a na-etinye ọkụ eletrik tupu ị rụọ ọrụ ọ bụla.
  2. Wepu mgbapụta: Jiri nlezianya wepụ ọkpọkọ ahụ na akwarium.
  3. Kwụsa: Gently twist or unclip the pump housing to access the impeller and internal components. Refer to the product diagram for specific disassembly steps.
  4. Ngwa dị ọcha: Use a soft brush and clean water (or a mild vinegar solution for stubborn calcium deposits) to clean the impeller, impeller shaft, and pump housing. Ensure all debris, algae, and mineral buildup are removed.
  5. Rinse and Reassemble: Rinse all components thoroughly with clean water. Reassemble the pump, ensuring all parts are correctly seated and secured.
N'elu view of the Jecod ECP-180M pump, showing its internal impeller design

Foto 8.1: Elu view of the Jecod ECP-180M pump, highlighting its cross-flow impeller design for maintenance access.

8.2 Controller Care

Keep the controller dry and away from direct water splashes. Wipe with a dry cloth if necessary.

9. Nchọpụta nsogbu

NsogbuIhe nwere ike imeNgwọta
Mgbapụta anaghị agbanwuNo power, loose connection, faulty adapter/controllerCheck power outlet, ensure all cables are securely connected. Test with another outlet.
Weak or no water flowImpeller clogged, pump not fully submerged, air in pumpDisconnect power, clean impeller and housing (refer to Maintenance). Ensure pump is fully submerged. Gently shake pump to release trapped air.
Pump na-eme mkpọtụ na-adịghị ahụkebeDebris in impeller, worn impeller, pump running dryDisconnect power, clean impeller. Ensure pump is fully submerged. If noise persists, impeller may be worn and require replacement.
Nsogbu njikọ Wi-FiIncorrect Wi-Fi password, controller too far from router, app issuesEnsure correct Wi-Fi password. Move controller closer to router. Restart app and controller. Consult app's help section.
Ngosipụta njikwa anaghị arụ ọrụPower issue, controller malfunctionCheck power connections. If power is present and display remains off, the controller may be faulty.

If troubleshooting steps do not resolve the issue, please contact your retailer or the manufacturer for further assistance.

10. Akwụkwọ ikike na nkwado

This product is covered by a manufacturer's warranty against defects in materials and workmanship. The specific terms and duration of the warranty may vary by region and retailer. Please retain your proof of purchase for warranty claims.

For technical support, warranty inquiries, or replacement parts, please contact the retailer from whom you purchased the product or refer to the official Jebao/Jecod websaịtị maka ozi kọntaktị ọrụ ndị ahịa.

Akwụkwọ ndị emetụtara - ECP-180M

Tupuview Akwụkwọ ntuziaka onye ọrụ Jebao Cross-Flow Wave Pump: CP-90, CP-120, CP-150
Akwụkwọ ntuziaka onye ọrụ maka mgbapụta Wave Jebao Cross-Flow, ụdị CP-90, CP-120, na CP-150. Gụnyere ntuziaka nchekwa, ntụzịaka mgbakọ, ọrụ njikwa, mmezi, na nkọwa nka.
Tupuview Akwụkwọ ntuziaka onye ọrụ Jebao Smart Wave - Ntọlite, arụmọrụ na nchọpụta nsogbu
Akwụkwọ ntuziaka onye ọrụ zuru oke maka Jebao Smart Wave Maker (MCP, MLW, MOW SERIES), na-ekpuchi nrụnye, njirimara, njikwa ngwa site na Jebao Aqua, ụdị ebili mmiri dị iche iche, nchọpụta nsogbu na mmezi. Mụta otu esi ahazi ma rụọ ọrụ onye na-eme ebili mmiri Jebao maka ọnọdụ akwarium kacha mma.
Tupuview Jebao E Series Wavemaker Pump User Manual
User manual for the Jebao E Series Wavemaker Pump, detailing product features, specifications, installation, operation, maintenance, and troubleshooting.
Tupuview Jebao RF-B Series Automatic Feeder User Manual
Comprehensive user manual for the Jebao RF-B Series Automatic Feeder, detailing installation, operation, features, maintenance, and troubleshooting for aquarium fish feeding.
Tupuview Ntuziaka Onye Ọrụ nke Jebao MDC Series Aquarium Pumps
Akwụkwọ ntuziaka maka igwe eji eme ihe maka ọkpọkọ mmiri Jebao MDC, atụmatụ zuru ezu, ntuziaka nchekwa, ntinye, ọrụ, na nkọwapụta teknụzụ. Gụnyere ụdị MDC-2000 ruo MDC-10000.
Tupuview Ntuziaka Onye Ọrụ nke Jebao AL & AK Series Aquarium Light - Ntọala, Atụmatụ, na Njikwa Ngwa
Akwụkwọ ntuziaka zuru oke maka ọkụ azụ mmiri Jebao AL na AK Series. Na-ekpuchi mmeghe ngwaahịa, nkọwapụta, ntinye, ntọala Wi-Fi, nbudata na njikwa ngwa, ụdịdị, na nsogbu nchọpụta.