Axis Communications 02621-001

Ntuziaka Onye Ọrụ Mgbanwe PoE++ nke AXIS D8208-R Industrial 8-Port Managed

Nle: 02621-001

1. Okwu mmalite

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Axis Communications D8208-R Industrial 8-Port Managed PoE++ Switch. This device is designed for robust industrial environments, offering reliable network connectivity and Power over Ethernet (PoE++) capabilities for connected devices. Please read this manual thoroughly before using the product to ensure proper and safe operation.

2. Ozi nchekwa

Lee ihe ndị a iji gbochie mmebi ngwaahịa ahụ ma hụ na onye ọrụ ahụ nwere nchekwa:

  • Isi mmalite ike: Use only the specified power supply for this device. Ensure the power source meets the voltage na ugbu a chọrọ.
  • gburugburu: Install the switch in an environment that complies with its operating temperature and humidity specifications. Avoid exposure to direct sunlight, excessive heat, moisture, or corrosive substances.
  • Igwe ikuku: Ensure adequate ventilation around the device to prevent overheating. Do not block ventilation openings.
  • Nwụnye: Ndị ọrụ ruru eru kwesịrị ịrụ nrụnye ahụ dịka iwu na ụkpụrụ eletriki mpaghara si dị.
  • Nlekọta: Do not attempt to open or service the device yourself. Refer all servicing to qualified service personnel.
  • Gịnị: Use appropriate and certified cables for all connections.

3. Ihe ngwugwu

Verify that all items are present in the package. If any item is missing or damaged, contact your supplier.

  • AXIS D8208-R Industrial 8-Port Managed PoE++ Switch
  • Ntuziaka nwụnye ngwa ngwa
  • Mounting Kit (e.g., DIN rail clip, screws)
  • Terminal Block Connectors (for power input)

4. Ngwaahịa gafereview

The AXIS D8208-R is a robust industrial switch designed for demanding applications. It features multiple Ethernet ports with Power over Ethernet capabilities and advanced management features.

4.1 Nhazi Panel Ihu

N'ihu view of AXIS D8208-R Industrial Switch showing ports and indicators

Foto 1: N'ihu view of the AXIS D8208-R Industrial Switch. This image displays the front panel of the switch, highlighting the various Ethernet ports, power input terminals, LED indicators, and the console port. Ports 1-4 are 1G PoE++ ports, ports 5-8 include 1G and 2.5G PoE++ capabilities, and ports 9-10 are 10G SFP+ ports.

Zuru ezu n'ihu view of AXIS D8208-R Industrial Switch

Foto 2: Zuru ezu n'ihu view of the AXIS D8208-R Industrial Switch. This image provides a closer look at the port configuration and LED indicators. It shows the two 10G SFP+ uplink ports (9 and 10) at the bottom, the console port, and the reset button. The power input terminals are visible on the right side.

4.2 Components Description

  • Ọdụ ụgbọ mmiri Ethernet (1-4): 1 Gigabit Ethernet ports with PoE++ (802.3bt) support.
  • Ọdụ ụgbọ mmiri Ethernet (5-8): 1 Gigabit and 2.5 Gigabit Ethernet ports with PoE++ (802.3bt) support.
  • 10G Ports (9-10): 10 Gigabit SFP+ uplink ports for high-speed connections.
  • Power Input (P1, P2): Redundant power input terminals for enhanced reliability.
  • Ọdụ ụgbọ mmiri: RJ45 port for local management and configuration via a serial connection.
  • Tọgharịa bọtịnụ: A na-eji ya emegharị ngwaọrụ ahụ ka ọ bụrụ ntọala ụlọ ọrụ mmepụta ihe ma ọ bụ malitegharịa.
  • Ihe ngosi LED:
    • Ụdị: Ngosipụta ọkwa sistemụ.
    • P1, P2: Power input status indicators.
    • ALM: Ihe ngosi mkpu.
    • RM, RC: Redundancy Management / Redundancy Control indicators.

5. Nhazi

5.1 Na-arịgo

The AXIS D8208-R is designed for DIN rail mounting.

  1. Attach the DIN rail clip (if not pre-installed) to the rear of the switch using the provided screws.
  2. Hook the top edge of the DIN rail clip onto the DIN rail.
  3. Push the bottom of the switch firmly towards the DIN rail until it clicks into place.
  4. Ensure the switch is securely fastened to the DIN rail.

5.2 Njikọ ike

The switch supports redundant power inputs (P1 and P2) for increased reliability.

  1. Ensure the power source is turned off before making any connections.
  2. Connect the positive (+) and negative (-) wires from your DC power supply to the corresponding terminals on the provided terminal block connector for P1.
  3. Insert the terminal block connector into the P1 power input port on the switch.
  4. (Optional) For redundant power, repeat steps 2 and 3 for the P2 power input.
  5. Once all connections are secure, turn on the power supply. The P1 and/or P2 LEDs should illuminate.

5.3 Njikọ netwọkụ

Connect network devices and uplink connections.

  • Ngwaọrụ ọkọlọtọ: Connect your network devices (e.g., IP cameras, access points) to ports 1-8 using standard Ethernet cables. These ports will provide PoE++ power if the connected device supports it.
  • Uplink: For high-speed uplink to your core network, insert compatible SFP+ transceivers into ports 9 and 10, then connect fiber optic cables.

5.4 Nhazi izizi

Enwere ike ịhazi mgba ọkụ site na a web-based interface or a command-line interface (CLI) through the console port.

  • Web Ihuenyo: Connect a computer to any Ethernet port on the switch. The switch will typically obtain an IP address via DHCP or use a default static IP. Refer to the Quick Installation Guide for the default IP address and login credentials.
  • Ọdụ ụgbọ mmiri: Connect a serial cable from your computer to the console port on the switch. Use a terminal emulation program (e.g., PuTTY) with the specified serial settings (e.g., 115200 baud, 8 data bits, no parity, 1 stop bit, no flow control) to access the CLI.

6. .rụ ọrụ

6.1 LED egosi

Monitor the LED indicators for the operational status of the switch.

IkanamỌnọdụNkọwa
SYSAkwụkwọ ndụ akwụkwọ ndụ (siri ike)Sistemu na-arụ ọrụ nke ọma.
SYSAgba ndụ ndụ (na -egbu maramara)System is booting or performing an operation.
P1/P2Akwụkwọ ndụ akwụkwọ ndụ (siri ike)Corresponding power input is active.
OkwaraRed (Solid/Flashing)An alarm condition exists (e.g., power failure, port error). Check system logs.
Port LEDAkwụkwọ ndụ akwụkwọ ndụ (siri ike)Ejikọtara njikọ.
Port LEDAgba ndụ ndụ (na -egbu maramara)Data activity.

6.2 Njikwa na nhazi

The AXIS D8208-R is a managed switch, offering a range of configuration options for network optimization and security.

  • WebGUI dabeere: Nweta mgba ọkụ web interface via a standard web browser to configure VLANs, QoS, port settings, PoE management, security features, and more.
  • CLI: For advanced users, the Command Line Interface provides granular control over all switch functions.
  • SNMP: The switch supports SNMP for integration with network management systems.

7. Nlekọta

7.1 Nhicha

To maintain optimal performance, periodically clean the exterior of the switch.

  • Gbaa mbọ hụ na agbapụrụ ike tupu ihicha.
  • Jiri akwa dị nro ma kpọọ nkụ hichapụ elu elu.
  • Do not use liquid or aerosol cleaners, as they may damage the device.
  • Debe oghere ikuku dị n'ebe ahụ pụọ na uzuzu na ihe ndị na-adịghị mma.

7.2 Mmelite firmware

Regularly check the Axis Communications website for the latest firmware updates. Firmware updates can provide new features, performance improvements, and security enhancements.

  • Budata ngwa ngwa kwesịrị ekwesị file from the official Axis Communications support page for your model.
  • Follow the instructions provided with the firmware update package for the correct update procedure, typically performed via the web interface.

8. Nchọpụta nsogbu

If you encounter issues with your AXIS D8208-R switch, refer to the following common troubleshooting steps.

  • Enweghị ike:
    • Check power cable connections to the switch and the power source.
    • Verify the power supply is functioning correctly and providing the correct voltage.
    • Ensure the P1/P2 LEDs are illuminated.
  • Enweghị njikọ netwọkụ:
    • Check Ethernet cable connections for both the switch and the connected device.
    • Verify the link/activity LEDs on the respective port are active.
    • Gbaa mbọ hụ na agbanyere ngwaọrụ ejikọrọ ma hazie ya nke ọma.
    • Check switch configuration (VLANs, port status) via the web interface ma ọ bụ CLI.
  • Ngwaọrụ PoE anaghị agbanye:
    • Ensure the connected device is PoE compatible and within the switch's PoE budget.
    • Check the PoE status for the port in the switch's management interface.
    • Verify the Ethernet cable is a standard Cat5e/6 or higher.
  • Ịnweta Web Interface Fails:
    • Confirm your computer's IP address is in the same subnet as the switch, or that DHCP is functioning.
    • Try accessing the switch via the console port to verify its IP configuration.
    • Hichapụ cache ihe nchọgharị gị ma ọ bụ nwaa ihe nchọgharị dị iche.
  • Tọgharia Factory: If issues persist and you need to restore default settings, press and hold the reset button for approximately 10-15 seconds until the SYS LED changes behavior, then release. Warning: This will erase all custom configurations.

9. Nkọwapụta

NjirimaraNkọwa
ỤdịMmekọrịta Axis
Nọmba nlereanya02621-001
Aha ngwaahịaAXIS D8208-R Industrial 8-Port Managed PoE++ Switch
ọdụ ụgbọ mmiri8 x PoE++ Ethernet (1G/2.5G), 2 x 10G SFP+
Ntinye ikeRedundant DC power input (terminal blocks)
Ibu Ibu3.37 pound (ihe dị ka 1.53 n'arọ)
Akụkụ ngwugwu1.97 x 0.79 x 0.79 sentimita (ihe dịka 5 x 2 x 2 cm)
Onye nrụpụtaAXIS - ACCESS CONTROL
Ụbọchị mbụ dịMee 29, 2024

10. Akwụkwọ ikike na nkwado

For detailed warranty information, technical support, and additional resources, please visit the official Axis Communications websaịtị.

Websaịtị: www.axis.com

Contact Axis Communications support for assistance with product installation, configuration, or troubleshooting beyond the scope of this manual.

Akwụkwọ ndị emetụtara - 02621-001

Tupuview Ntuziaka Nhazi Mgbanwe Axis Network - Ntọala na Njikwa
Nduzi zuru oke maka ndị nchịkwa netwọk gbasara ịhazi na ijikwa swiiti netwọk AXIS T85 na D8208-R. Na-ekpuchi nhazi, atụmatụ, nchekwa, na nsogbu nchọpụta.
Tupuview Ntuziaka Nwụnye AXIS High PoE Midspan na Splitters
Ntuziaka ntinye maka AXIS T8123 High PoE Midspan na AXIS T8126/T8128 High PoE Splitters, na-ekpuchi ntọala, nkọwapụta, na nchọpụta nsogbu maka ngwọta Power over Ethernet.
Tupuview Ntuziaka ntinye nke ihe mmetụta ikuku AXIS D6310
Ntuziaka ntinye zuru oke maka ihe mmetụta AXIS D6310 nke ikuku. Mụta otu esi etinye, jikọọ, na hazie ngwaọrụ gị n'enweghị nsogbu na nke ọma. Gụnyere nrubeisi iwu, ntuziaka nchekwa, na nkọwapụta teknụzụ.
Tupuview AXIS M43 Panoramic Camera Series Installation Guide
This installation guide provides essential information for setting up the AXIS M43 Panoramic Camera Series, including models AXIS M4327-P and AXIS M4328-P. It covers installation procedures, safety, and regulatory compliance.
Tupuview Akwụkwọ ntuziaka del usuario de cámaras tipo domo AXIS M30
Guía completa para la instalación, configuración y uso de las cámaras tipo domo AXIS M30, incluyendo detalles sobre imagen, vídeo, audio, aplicaciones na ciberseguridad.
Tupuview Ntuziaka ntinye nwụnye AXIS TP3201-E
Ntuziaka a na-enye ntụziaka maka ịwụnye AXIS TP3201-E Recessed Mount, gụnyere ozi nchekwa, ihe gbasara iwu, na usoro mgbakọ nzọụkwụ site na nzọụkwụ maka ụdị igwefoto AXIS dakọtara.