Okwu mmalite
The CDN Digital Probe Cooking, Cooling Thermometer, Smoker Oven Grill Candy Deep Frying, Multifunctional Thermometer/Timer/Clock (Model DTTC-W) is a versatile tool designed to assist in precise temperature monitoring for various cooking and cooling applications. This manual provides detailed instructions for setup, operation, maintenance, and troubleshooting to ensure optimal performance and longevity of your device.
Ozi nchekwa
- Always handle the stainless steel probe with care as it can become very hot during use. Use oven mitts or heat-resistant gloves when removing the probe from hot food or ovens.
- Do not immerse the main thermometer unit in water or any other liquid. The unit is not waterproof. Clean only the probe and cable.
- Ensure the probe cable is not pinched or damaged by oven doors or grill grates, as this can affect accuracy and damage the cable.
- Debe ngwaọrụ ahụ ka ụmụaka ghara iru ya.
- Ejila temometa na oven microwave.
- Only use the specified battery type (1 AAA).
Ngwa
Your CDN DTTC-W package includes the following components:
- Digital Thermometer/Timer/Clock Unit
- Stainless Steel Probe with High-Heat Sensor Cable
- Mpempe ite
- Batrị AAA 1 (gụnyere)

Image: The CDN Digital Probe Thermometer DTTC-W unit, showing the main display, control buttons, the stainless steel probe, and the pot clip.
Melite
- Nwụnye batrị:
Locate the battery compartment on the back of the main unit. Open the compartment cover and insert one AAA battery, ensuring correct polarity (+/-). Close the cover securely.
- Njikọ nyocha:
Insert the plug of the stainless steel probe cable into the jack located on the side of the main unit. Ensure it is fully inserted for proper connection.

Foto: A nso nso view of the stainless steel probe and its high-heat sensor cable, ready for connection to the main unit.
- Ndokwa otu:
The DTTC-W offers two mounting options:
- Azụ magnetik: The unit has magnetic strips on its back, allowing it to be securely attached to metal surfaces like a refrigerator door or oven exterior.
- Fold-out Stand: A hinge allows the unit to sit upright on a countertop or stovetop for easy viewing.

Image: The thermometer unit attached to an oven door via its magnetic back, demonstrating the magnetic mounting option.

Image: The thermometer unit standing upright on a countertop using its integrated fold-out stand.
Ntuziaka ọrụ
The DTTC-W features a clear LED screen displaying time, current food temperature, and set temperature. Buttons are clearly marked for ease of use.
Ụdị ọrụ:
Pịa MODE button to cycle through the three main modes: Thermometer, Timer, and Clock.
1. Thermometer Mode:
- Okpu igwe: Insert the stainless steel probe into the thickest part of the food, avoiding bone or gristle. The current internal temperature will be displayed on the screen.
- Setting Temperature Alert:
- Pịa NKWUKWU button. The set temperature will flash.
- Jiri ihe UP na N'ala buttons to adjust the desired target temperature.
- Pịa NKWUKWU ọzọ iji kwado ntọala ahụ.
- When the food reaches the set temperature, an alarm will sound. Press any button to silence the alarm.
- Fahrenheit/Celsius Selection: Use the switch on the back of the unit to toggle between Fahrenheit (°F) and Celsius (°C) temperature scales.
- Using the Pot Clip: For deep frying or candy making, attach the pot clip to the side of your saucepan. Insert the probe through the clip, ensuring the probe tip is submerged in the liquid but not touching the bottom of the pan.

Image: The pot clip securely attached to the rim of a saucepan, holding the probe in place for accurate temperature monitoring during cooking.
2. Timer Mode:
- Ịtọ ngụ oge:
- Pịa HR na MIN bọtịnụ iji tọọ oge ngụta achọrọ.
- Pịa Malite/Kwụsị ibido ngụkọ.
- Ka ịkwụsịtụ, pịa Malite/Kwụsị ọzọ. Pịa ọzọ ka ịmaliteghachi.
- Ka ikpochapụ oge, pịa CLR.
- An alarm will sound when the timer reaches zero. Press any button to silence.
- Count-Up Timer:
From Timer mode, ensure the timer is set to 0:00. Press Malite/Kwụsị to begin counting up. Press Malite/Kwụsị to pause/resume, and CLR iji tọgharịa.
3. Clock Mode:
- Ịtọ elekere:
- In Clock mode, press and hold the MODE bọtịnụ ruo mgbe ọnụọgụgụ awa ahụ na-enwu.
- Jiri ihe HR na MIN buttons to set the hour and minute respectively.
- Pịa MODE iji gosi ntọala ọ bụla.
- The clock displays 12-hour or 24-hour time.

Image: The thermometer probe accurately measuring the internal temperature of a chicken roasting inside an oven.

Image: The thermometer probe inserted into chicken breasts cooking on a grill, demonstrating its use for outdoor cooking.
Nlekọta
- Nhicha:
The stainless steel probe and cable can be cleaned with a damp cloth and mild detergent. Rinse thoroughly and dry immediately. The main unit should be wiped clean with a damp cloth only. Do not immerse the main unit in water.

Image: The thermometer unit and probe resting on a wooden cutting board, illustrating the ease of access for cleaning after use.
- Ngbanwe batrị: Replace the AAA battery when the display dims or the unit stops functioning correctly.
- Nchekwa: Store the thermometer in a clean, dry place when not in use. Avoid extreme temperatures or direct sunlight.
Nchọpụta nsogbu
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Enweghị ngosipụta ma ọ bụ ngosipụta dị nro. | Batrị nwụrụ anwụ ma ọ bụ arụnyere na-ezighi ezi. | Dochie batrị AAA, hụ na polarity ziri ezi. |
| Ọgụgụ okpomọkụ ezighi ezi. | Probe not fully inserted, damaged probe/cable, or probe tip touching bone/pan. | Ensure probe is fully inserted. Check cable for damage. Reposition probe to avoid bone/pan. If issues persist, the probe may need replacement. |
| Oti mkpu anaghị ada ụda. | Alarm volume too low (if adjustable, though this model doesn't specify), or alarm setting incorrect. | Verify alarm temperature is set correctly. Ensure the unit is not in a location where the sound is muffled. |
| Unit resets or freezes. | Batrị dị ala ma ọ bụ nsogbu dị n'ime. | Dochie batrị. Ọ bụrụ na nsogbu ahụ anọgide, kpọtụrụ ndị ahịa. |
Nkọwapụta
- Oke nha: 14 to 392°F / -10 to +200°C
- Ogologo oge: Up to 24 hours by hr/min
- Ogologo nyocha: 5.5 sentimita (14.0 cm)
- Ogologo eriri ihe mmetụta: 3 ụkwụ (91.4cm)
- Sensor Cable Heat Resistance: Ruo 600°F/315°C
- Isi mmalite ike: 1 x 1.5V AAA IEC LR03 Alkaline Battery (included)
- Ụdị ngosi: Dijitalụ LCD
- Nhọrọ nkwụnye: Magnetic back, Fold-out stand
- Akụrụngwa: Stainless Steel probe, Plastic unit casing
- Akụkụ ngwaahịa: 10.5 x 6 x 1.3 inches; 4 ounces (approximate)
Akwụkwọ ikike
The CDN Digital Probe Cooking Thermometer (DTTC-W) is covered by a two-year warranty against defects in materials and workmanship from the date of purchase. This warranty does not cover damage resulting from misuse, abuse, accident, or unauthorized alteration or repair. Please retain your proof of purchase for warranty claims.
Nkwado
For technical assistance, warranty claims, or general inquiries, please contact CDN Customer Service. Refer to the official CDN websaịtị maka ozi kọntaktị kacha ugbu a.
Websaịtị: www.cdn-timeandtemp.com