Okwu mmalite
This manual provides essential information for the safe and efficient operation of your Tektronix MSO22 2-BW-100 Mixed Signal Oscilloscope. This instrument is designed for precise measurement and analysis of electronic signals, featuring a 100 MHz bandwidth and 2 analog channels.
Atụmatụ gụnyere:
- Analog input channels: 2 inputs
- Mgbasa ozi: 100 MHz
- Sample rate: 2.5 GS/s Half channels; 1.25 GS/s All channels
- Record length: 10 Mpoints per channel
- Vertical resolution: 8 bits ADC; Up to 16 bits in high-resolution mode
Ntọala na Njikọ
Before operating the oscilloscope, ensure it is placed on a stable, level surface with adequate ventilation. Connect the power cord to the instrument and a grounded AC outlet.

Figure 1: Front panel of the Tektronix MSO22 2-BW-100 Oscilloscope, showing the display, control knobs, buttons, and input connectors (Inputs 1, 2, Aux In, AFG/Aux Out).
Ntinye njikọ
- Analog Inputs (1, 2): Connect your probes to these BNC connectors for signal acquisition.
- Aux n'ime: Auxiliary input for external trigger or other signals.
- AFG/Aux Out: Output for the Arbitrary Function Generator or auxiliary signals.
Gbanyụọ
Press the power button located on the front panel to turn on the instrument. Allow a few moments for the system to boot up.
Ntuziaka ọrụ
This section outlines the basic steps for operating the oscilloscope to capture and analyze waveforms.
Basic Waveform Capture
- Connect Probe: Attach a compensated probe to one of the analog input channels (e.g., Input 1).
- Connect to Circuit: Connect the probe tip to the test point in your circuit and the ground clip to the circuit's ground.
- Auto-Set: Pịa Auto-Set button (if available, common on oscilloscopes) to automatically adjust vertical and horizontal settings for a stable display.
- Adjust Vertical Scale: Jiri ihe Ọnụ ọgụgụ kwụ ọtọ knob to adjust the volts per division, controlling the amplitude of the waveform on the screen.
- Adjust Horizontal Scale: Jiri ihe Ọnụ ọgụgụ kwụ ọtọ knob to adjust the seconds per division, controlling the time base of the waveform.
- Adjust Trigger: Jiri ihe Ọkwa na-akpalite bọtịnụ iji tọọ vol ahụtage level at which the oscilloscope captures the waveform, ensuring a stable display.
Ọrụ Nnwale
The MSO22 2-BW-100 offers various automated measurement functions. Access these through the on-screen menu system. Common measurements include Peak-to-Peak Voltage, Frequency, Period, and Rise/Fall Time.
Nlekọta
Proper maintenance ensures the longevity and accuracy of your oscilloscope.
Nhicha
- Jiri nwayọ hichaa elu mpụta, damp akwa . Ejila ihe nchacha abrasive ma ọ bụ ihe mgbaze.
- Hụ na mmiri ọ bụla abanyeghị n'ime ngwa ahụ.
- Clean the display screen with a soft, lint-free cloth specifically designed for electronic displays.
nhazi nhazi
For optimal performance, periodic calibration by qualified service personnel is recommended. Refer to the official Tektronix service manual for calibration procedures and intervals.
Nchọpụta nsogbu
Akụkụ a na-enye azịza maka nsogbu nkịtị ị nwere ike izute.
- Enweghị Ngosipụta:
- Ensure the power cord is securely connected and the instrument is powered on.
- Check the brightness and contrast settings of the display.
- Ụdị Wave Na-adịghị Akwụsi Ike:
- Adjust the trigger level and trigger source settings.
- Verify the probe compensation is correct.
- Check for proper grounding of the probe and the circuit under test.
- No Signal Detected:
- Ensure the probe is correctly connected to the input channel and the circuit.
- Check the input coupling (AC/DC/GND) and vertical scale settings.
- Verify the signal source is active.
If problems persist, contact Tektronix customer support.
Nkọwapụta
Detailed technical specifications for the Tektronix MSO22 2-BW-100 Mixed Signal Oscilloscope.
| Njirimara | Nkọwapụta |
|---|---|
| Nọmba nlereanya | MSO22 2-BW-100 |
| Ọwa Ntinye Analog | Ntinye 2 |
| Bandwit | 100 MHz |
| Sample Rate (Half Channels) | 2.5 GS/s |
| Sample Rate (All Channels) | 1.25 GS/s |
| Ogologo ndekọ | 10 Mpoints per channel |
| Mkpebi Vetikal | 8 bits ADC; Up to 16 bits in high-resolution mode |
| Onye nrụpụta | Tektronix |
| Ụbọchị mbụ dị | Ọnwa Isii 17, 2022 |
Akwụkwọ ikike na nkwado
Tektronix products are designed for reliability and performance. For information regarding product warranty, please refer to the warranty statement included with your purchase or visit the official Tektronix websaịtị.
For technical support, service, or additional documentation, please contact Tektronix customer service or visit their official support portal. Ensure you have your product model number (MSO22 2-BW-100) and serial number ready when contacting support.
Akụrụngwa dị n'ịntanetị: www.tek.com