1. Okwu mmalite
Thank you for choosing the Philips MAUVE PIR CL252 Functional Ceiling Light. This manual provides essential information for the safe installation, operation, and maintenance of your new lighting fixture. This LED ceiling light features an integrated motion sensor and provides warm white illumination, ideal for functional areas within your home.

Ọgụgụ 1.1: N'elu-ala view of the Philips MAUVE PIR CL252 ceiling light, highlighting the central motion sensor.

Figure 1.2: Two Philips MAUVE PIR CL252 ceiling lights installed in a modern hallway, demonstrating their illumination in a functional area.
2. Ozi nchekwa
Biko gụọ ntuziaka nchekwa niile nke ọma tupu etinyere ma jiri ya. Debe akwụkwọ ntuziaka a maka ntụaka n'ọdịnihu.
- Nchekwa Eletriki: Installation should only be performed by a qualified electrician or competent person in accordance with local electrical codes and regulations. Always disconnect power at the main circuit breaker before installation, maintenance, or cleaning.
- Ijikwa: Do not handle the product with wet hands. Avoid touching the light source directly when the fixture is powered on.
- Eji ime ụlọ naanị: This product is designed for indoor use (Innenbereich) only. Do not expose it to water or high humidity.
- Igwe ikuku: Ensure adequate ventilation around the fixture. Do not cover the light fixture with any materials.
- Mmebi: Do not use the product if it is damaged. Contact customer support for assistance.
3. Ihe ngwugwu
Nyochaa na akụrụngwa niile dị na emebighị ya tupu ịga n'ihu na ntinye.
- Philips MAUVE PIR CL252 Ceiling Light fixture
- Akụrụngwa mgbanye (skru, plọg mgbidi)
- Akwụkwọ ntuziaka (akwụkwọ a)

Figure 3.1: The retail packaging for the Philips MAUVE PIR CL252 LED ceiling light, showing key features.
4. Ntọala na nwụnye
This ceiling light requires placement and electrical connection. Follow these steps carefully.
- Nkwadebe: Gbaa mbọ hụ na agbanyụrụ ọkụ na mpaghara nrụnye na isi sekit.
- Ebe Nkwanye: Choose a suitable location on the ceiling. The fixture is designed for indoor ceiling installation.
- Ịka akara na igwu mmiri: Use the mounting bracket (if separate) or the fixture itself as a template to mark the drilling points on the ceiling. Drill holes of appropriate size for the provided wall plugs.
- Wiring: Connect the electrical wires from the ceiling to the terminals on the light fixture. Ensure correct polarity (Live, Neutral, Earth) as indicated on the fixture or in the wiring diagram. Secure all connections.
- Ịkwanye ihe ndozi ahụ: Secure the light fixture to the ceiling using the provided screws and wall plugs. Ensure it is firmly attached and stable.
- Ike Na: Ozugbo e mechara nrụnye ahụ ma njikọ niile dị nchebe, weghachite ike na isi ihe mgbawa sekit ahụ.

Figure 4.1: Technical diagram illustrating the dimensions of the Philips MAUVE PIR CL252 ceiling light (Ø320mm diameter, 72mm height).
5. Ntuziaka ọrụ
The Philips MAUVE PIR CL252 features an integrated motion sensor for automatic illumination.
- Mgbalite ihe mmetụta ngagharị: The light will automatically turn on when motion is detected within its sensing range.
- Nwepu akpaaka: The light is designed to turn off approximately 30 seconds after motion is no longer detected. This duration is fixed and cannot be adjusted.
- Light Conditions: The PIR (Passive Infrared) sensor also incorporates a dusk-to-dawn sensor, meaning the light will primarily activate in low-light conditions to conserve energy.
- Njikwa ọkụ Smart: This luminaire supports smart lighting control, potentially via an application. Refer to the Philips website or additional documentation for details on app compatibility and features.

Figure 5.1: The Philips MAUVE PIR CL252 ceiling light with an overlay icon indicating its integrated motion sensor functionality.

Figure 5.2: The Philips MAUVE PIR CL252 ceiling light illuminated, demonstrating its warm white light output at 2700K.

Figure 5.3: The Philips EyeComfort logo, indicating that the product is designed for visual comfort. Consult product details for more information on flicker and stroboscopic effects.
6. Nlekọta
Regular cleaning and proper care will ensure the longevity and optimal performance of your ceiling light.
- Nhicha: Always disconnect power before cleaning. Use a soft, dry, or slightly damp cloth to wipe the surface of the fixture. Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the finish or electronic components.
- Ndokwa bọlbụ: This fixture uses integrated LED technology, meaning the LED light source is not user-replaceable. If the light source fails, the entire fixture may need to be replaced.
- Mwepụ nke Bọlbụ Gbajiri Agbaji: In case of accidental breakage or damage to the light source, exercise caution. Do not touch broken glass or components with bare hands. Refer to local regulations for proper disposal of broken or deteriorated light bulbs and electronic waste.
7. Nchọpụta nsogbu
If you encounter issues with your Philips MAUVE PIR CL252, refer to the following common problems and solutions.
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Ìhè anaghị agbanwuo. | Enweghị ọkụ. | Check circuit breaker and wall switch. Ensure proper electrical connection. |
| Light turns on but immediately turns off. | Ihe ihe mmetụta egbochiri ma ọ bụ mejọrọ. | Ensure the motion sensor is clear of obstructions. If problem persists, contact support. |
| Ìhè na-anọgide na-enwu. | Constant motion detected or sensor malfunction. | Ensure no continuous motion is within the sensor's range. If problem persists, contact support. |
| Motion sensor is not detecting movement. | Sensor sensitivity issue or incorrect placement. | Ensure the sensor is not blocked. Verify the light conditions are suitable for activation (e.g., not too bright). |
Ọ bụrụ na nsogbu ahụ anọgide mgbe ị nwalechara ngwọta ndị a, biko kpọtụrụ ndị ahịa Philips.
8. Nkọwapụta
Detailed technical specifications for the Philips MAUVE PIR CL252 Functional Ceiling Light.
| Njirimara | Nkọwa |
|---|---|
| Nọmba nlereanya | 929003195801 |
| Ụdị | Philips Lighting |
| Akụkụ ngwaahịa | 32 x 32 x 8.2 cm (Diameter x Height) |
| Ibu | 481 g |
| Agba | Ọcha |
| Ihe onwunwe | Plastic (Kunststoff) |
| Luminaire Form | Ụlọ elu |
| Ụdị | Mauve with Motion Sensor |
| Isi Iyi Ike | AC/DC |
| Ojiji akọwapụtara | Indoor Use (Innenbereich) |
| Ụdị ọkụ | Igwe ọkụ agbakwunyere |
| Okpomọkụ agba | 2700K (Ọcha na-ekpo ọkụ) |
| Atụmatụ pụrụ iche | Integrated Motion Sensor, EyeComfort Technology |
| Mba onye si | Spain |
9. Ntugharị na mkpofu
This product contains electronic components and should be disposed of responsibly. Do not dispose of the product with general household waste.
- Imegharị: Please refer to local regulations for information on recycling electronic products and light fixtures. Many regions have collection points for electrical and electronic equipment.
- Ọgwụgwụ-ndụ: At the end of its life, the product should be taken to an authorized collection point for recycling to prevent potential harm to the environment and human health from uncontrolled waste disposal.
10. Akwụkwọ ikike na nkwado
For warranty information, technical support, or service inquiries, please refer to the documentation included with your purchase or visit the official Philips Lighting websaịtị. Debe ihe akaebe nke ịzụrụ maka akwụkwọ ikike.
Philips Lighting Customer Support: www.philips.com/support





