Okwu mmalite
This manual provides essential information for the safe installation, operation, and maintenance of your EMKE Flat Panel Towel Radiator. Please read these instructions thoroughly before installation and retain them for future reference. This hot water radiator is designed to provide efficient heating for your bathroom and dry towels effectively.
Ozi nchekwa
- Installation must be performed by a qualified professional in accordance with local building and plumbing regulations.
- Ensure the heating system is completely drained and depressurized before attempting any installation or maintenance.
- The radiator surface will become hot during operation. Avoid prolonged direct contact to prevent burns.
- Do not hang excessively heavy items on the radiator, as this may compromise its stability or damage the unit.
- Keep children and pets away from the radiator when it is in operation.
- Do not block the airflow around the radiator, as this can reduce its efficiency and potentially cause overheating.
Ngwaahịa gafereview
The EMKE Flat Panel Towel Radiator is constructed from high-quality mild steel, ensuring durability and efficient heat transfer. It features a modern design with flat panels, optimized for both heating performance and aesthetic appeal. The unit has passed the DIN EN 442 test and uses AkzoNobel ecological paints for a high-quality finish.
Akụkụ ndị bụ isi:
- Akụkụ: 1041 mm (height) x 500 mm (width)
- Mmepụta ọkụ: 529 W
- Mpaghara Ngwa: Kwesịrị ekwesị maka ọnụ ụlọ ruo 5 m²
- Ihe: High-quality mild steel with environmental protection coating
- Agba: Anthracite
- Ụdị njikọ: Hot water, side connection
- Ichekwa oghere: Wall-mounted to maximize bathroom space.

Image: High-quality materials and advanced welding technology ensure durability and performance.

Image: Wide flat tubes for fast drying and adjustable wall distance for flexible installation.
Ntọala (Nwụnye)
Ngwa na ngwa achọrọ (anaghị etinye ya):
- Kwuo egwu
- Ọkwa mmụọ
- Ihe teepu
- Pensụl
- mgbanaka nwere ike idozi
- Sealant tape (PTFE tape)
- Valves (G1/2" connection, 50mm spacing)
Nzọụkwụ nwụnye:
- Bupụ ma nyochaa: Carefully unpack all components and inspect for any damage. Ensure all included accessories are present.
- Marking Drill Holes: Using the provided technical drawing and a spirit level, mark the positions for the wall mounting brackets on your wall. The distance from the wall to the outer edge of the radiator will be between 99-115 mm.
- Oghere egwu egwu: Drill holes at the marked positions suitable for the wall plugs and screws.
- Wụnye brackets: Insert wall plugs and securely fasten the support brackets to the wall using the long screws.
- Ugwu Radiator: Carefully lift the radiator and attach it to the installed wall brackets. Secure it with the small screws and bolts.
- Connect Valves: The towel radiator can be connected on either the left or right side. The connection thread is G1/2" with a 50mm spacing. Note: Valves are not included and must be purchased separately. The valve must be connected at the bottom.
- Ule ntapu: Once connected, slowly refill your heating system and check all connections for leaks. Tighten any leaking connections as necessary.

Image: Flexible installation options for left or right side connection.

Image: Technical drawing showing dimensions (1041x500mm) and wall mounting details.

Image: Included accessories for installation and secure four-layer packaging.
Ntuziaka ọrụ
The EMKE Flat Panel Towel Radiator operates as part of your central heating system. Once installed and connected to your hot water circuit, it will heat up when your central heating is active.
- Ensure your central heating system is functioning correctly.
- Open the valves connected to the radiator to allow hot water to circulate through the unit.
- The radiator will begin to heat, providing warmth to your bathroom and drying towels placed on its bars.
- For optimal towel drying, distribute towels evenly across the bars without overcrowding.

Image: High thermal conductivity ensures efficient heating of the room and towels.
Nlekọta
Regular maintenance ensures the longevity and efficient operation of your towel radiator.
- Nhicha: Clean the radiator regularly with a soft, damp akwa . Ejila ihe nchacha abrasive, ihe mgbaze, ma ọ bụ kemịkalụ siri ike, n'ihi na ndị a nwere ike imebi njedebe.
- Ọbara: Periodically bleed the radiator to release any trapped air. This is typically done using the ventilation valve located on the top of the radiator. Trapped air can reduce heating efficiency.
- Nleba anya ntapu: Regularly inspect all connections for any signs of leaks. Address any leaks promptly to prevent water damage.
- Nrụgide Sistemu: Ensure your central heating system maintains the correct pressure as recommended by your heating system manufacturer.
Nchọpụta nsogbu
If you encounter issues with your EMKE towel radiator, refer to the following common problems and solutions:
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Radiator not heating or only partially heating | Ikuku tọrọ atọ na sistemụ | Bleed the radiator using the ventilation valve. |
| A na-emechi valvụ | Ensure both inlet and outlet valves are fully open. | |
| Usoro nrụgide dị ala | Check your central heating system's pressure gauge and repressurize if necessary. | |
| Mmiri na-agbapụta site na njikọ | Loose connection or worn sealant | Tighten connections. If leaking persists, drain the system, reapply sealant tape, and re-tighten. |
| Radiator making noise (gurgling) | Ikuku na usoro | Bleed the radiator. |
If the problem persists after attempting these solutions, please contact a qualified heating engineer or EMKE customer support.
Nkọwapụta
| Njirimara | Nkọwa |
|---|---|
| Ụdị | EMKE |
| Nọmba nlereanya | SFTR1050X1A |
| Akụkụ (H x W) | 1041 mm x 500 mm |
| Mmepụta ọkụ | 529 W |
| Ihe onwunwe | Metal (Mild Steel) |
| Agba | Anthracite |
| Ụdị ike | Hot Water (Central Heating) |
| Eriri Njikọ | G1/2" |
| Oghere njikọ | 50 mm |
| Wall Distance (Adjustable) | 99-115 mm |
| Akụkụ ngwugwu | 112.5 x 57 x 10 cm |
| Ibu ngwugwu | 13.9 n'arọ |
| Asambodo | EN 442 |
Akwụkwọ ikike na nkwado
EMKE products are manufactured to high standards and come with a standard manufacturer's warranty. For specific warranty details, please refer to the documentation provided with your purchase or visit the official EMKE websaịtị.
If you require technical assistance, have questions about installation, or need to report a fault, please contact EMKE customer support. Have your model number (SFTR1050X1A) and purchase details ready when contacting support.
EMKE Customer Support:
- Refer to your purchase invoice or the EMKE websaịtị maka ozi kọntaktị.
- Online resources and FAQs may also be available on the EMKE brand store or product page.





