TRU Components TC-9539292

TRU COMPONENTS TC-9539292 LED Signal Column User Manual

Ụdị: TC-9539292

Okwu mmalite

The TRU COMPONENTS TC-9539292 is a robust and durable LED signal column designed for industrial applications. It provides clear visual and audible indications for various operational states. This manual provides essential information for the safe and effective installation, operation, and maintenance of your signal column.

TRU COMPONENTS TC-9539292 LED Signal Column with red and green light segments and attached power cable.

Image: TRU COMPONENTS TC-9539292 LED Signal Column. This image displays the TRU COMPONENTS TC-9539292 LED Signal Column. The column features two distinct light segments: an upper red segment and a lower green segment. A black power cable with exposed wires at the end is shown coiled next to the column, indicating its electrical connection. The base of the signal column includes a threaded section for mounting.

Ozi nchekwa

Na-agbaso ihe ndị a dị mkpa mgbe niile iji gbochie mmerụ ahụ na mmebi nke ngwaọrụ ahụ:

  • Hụ na ewepụla ọkụ eletrik tupu echichi ya, idozi ya, ma ọ bụ dozie nsogbu ya.
  • Installation should only be performed by qualified personnel in accordance with local electrical codes and regulations.
  • Do not expose the device to excessive moisture, dust, or extreme temperatures outside its specified operating range.
  • Chọpụta voltaji ziri ezitage (24 Volts) before connecting the device.
  • Do not attempt to modify or repair the device yourself. Refer to qualified service personnel.

Ntọala na nwụnye

Follow these steps for proper installation of the signal column:

  1. Ịkwanye: The signal column features a threaded base (M2x15, Hexagonal head style) for secure mounting. Ensure the mounting surface is stable and capable of supporting the device's weight (119 grams).
  2. Wiring: Connect the signal column to a 24 Volt power supply. The cable includes multiple wires; refer to the specific wiring diagram provided with your equipment for correct connections to control the red and green LED segments and the audible alarm. Ensure all connections are secure and insulated.
  3. Ihe gbasara gburugburu: Install the column in an environment that is free from excessive vibration and within the recommended operating temperature range. The material is plastic.

Ntuziaka ọrụ

The TRU COMPONENTS signal column offers both visual and audible indications:

  • Ngosipụta anya: The red and green LED segments can be configured for either continuous illumination or na-egbu maramara. The specific control signals for these modes will depend on your system's integration.
  • Audible Indication: The integrated sounder can produce either a ụda na-aga n'ihu ma ọ bụ a discontinuous tone (intermittent sound). Consult your system's control logic for activating these audible alerts.

The signal column is designed to integrate with industrial control systems to provide real-time status updates.

Nlekọta

The TRU COMPONENTS signal column is designed for durability and requires minimal maintenance. However, regular checks can extend its lifespan and ensure reliable operation:

  • Nhicha: Periodically clean the exterior of the column with a soft, damp akwa . Ejila ihe nchacha abrasive ma ọ bụ ihe mgbaze.
  • Nyocha: Regularly inspect the wiring and connections for any signs of wear, damage, or loose connections. Ensure the mounting is secure.
  • Lelee LED: Verify that both red and green LED segments illuminate correctly when activated.
  • Sounder Check: Confirm the sounder functions as expected when activated.

Kwupu ike mgbe niile tupu ime mmezi ọ bụla.

Nchọpụta nsogbu

If you encounter issues with your signal column, refer to the following common problems and solutions:

NsogbuIhe nwere ike imeNgwọta
Enweghị ọkụ ma ọ bụ ụdaNo power supply; Incorrect wiring; Faulty unitCheck power connection (24V); Verify wiring against diagram; Contact support if power and wiring are correct.
Only one LED segment illuminatesIncorrect wiring for specific segment; Faulty LED segmentCheck wiring for the non-illuminating segment; If wiring is correct, the segment may be faulty.
Sounder not workingIncorrect wiring for sounder; Faulty sounderVerify sounder wiring; If wiring is correct, the sounder may be faulty.
Ọrụ na-adịte akaLoose connections; Unstable power supplyCheck all wiring connections for tightness; Ensure power supply is stable.

For issues not listed above, or if solutions do not resolve the problem, please contact TRU Components customer support.

Nkọwapụta

Nọmba nlereanyaNK-9539292
Onye nrụpụtaNgwakọta TR
Akụkụ (L x W x H)10 x 10 x 15 cm
Ibu119 grams
AgbaRed, Green
Ihe onwunwePlastic
Voltage24 volts
Ọnụọgụ nke Iberibe1
Ụdị isiHexagonal
Sistemụ nhaMetric
Nha eriri1/4"-20 UNC
AtụmatụContinuous or flashing illumination, Continuous or discontinuous sounder

Akwụkwọ ikike na nkwado

TRU Components provides a 1-year availability for spare parts for the TC-9539292 LED Signal Column from the date of purchase.

For technical support, warranty claims, or further assistance, please contact your point of purchase or visit the official TRU Components website. Ensure you have your model number (TC-9539292) and purchase details ready when contacting support.

Akwụkwọ ndị emetụtara - NK-9539292

Tupuview TRU COMPONENTS USB LED Signal Light Data Sheet
Technical data and operation instructions for the TRU COMPONENTS USB LED Signal Light (Item no. 2804760), featuring 7 colors and buzzer functionality.
Tupuview Akwụkwọ ntuziaka onye ọrụ TRU Components LED Transformer na nkọwa nka
Akwụkwọ ntuziaka onye ọrụ zuru oke na nkọwa teknụzụ maka TRU Components LED transformers, gụnyere nọmba nlereanya, data eletriki, ọnọdụ ọrụ, yana ụkpụrụ nchekwa maka ngwa ọkụ ọkụ ime ụlọ.
Tupuview Ngwa TRU DIN Nchekwa na data teknụzụ na-eweta ike ụgbọ oloko
Ntuziaka nchekwa zuru oke, ojiji e bu n'obi, nkọwa akara, na nkọwa nka maka TRU Components DIN Rail Power Supplies, gụnyere nọmba nlereanya na paramita arụ ọrụ.
Tupuview TRU COMPONENTS DIN-rail Voedingen Gebruiksaanwijzing na nkọwapụta.
Gedetailleerde gebruiksaanwijzing na technische nkọwapụta voor TRU COMPONENTS DIN-rail voedingen. Họrọ installatie-ntụziaka, veiligheidsinformatie na modelgegevens voor iche iche uitvoeringen.
Tupuview TRU COMPONENTS DIN Rail Power Supply - User Manual and Specifications
Comprehensive operating instructions and technical specifications for TRU COMPONENTS DIN Rail Power Supplies, covering safety, installation, and detailed product data. Includes model numbers, electrical characteristics, dimensions, and safety guidelines.
Tupuview TRU COMPONENTS DIN Rail Power Supply User Manual and Specifications
Comprehensive user manual and technical specifications for TRU COMPONENTS DIN rail power supplies, including models DPN, DPS, and DPH series. Covers intended use, safety instructions, installation, cleaning, and detailed electrical and physical specifications.