1. Okwu mmalite
This manual provides detailed instructions for the installation, operation, and maintenance of your EMOS OpenTherm Wireless Digital Programmable Room Thermostat, model P5611OT. This advanced thermostat system is designed to efficiently control heating or air conditioning systems in various environments, including homes, offices, and other residential or commercial spaces.
The P5611OT system comprises two main components: a portable Control Unit (Transmitter) and a fixed Switching Unit (Receiver). These units communicate wirelessly via an 868 MHz radio signal, allowing flexible placement of the control unit while the receiver manages the connection to your heating or cooling appliance.
2. Ngwa ngwaahịa
Your EMOS P5611OT thermostat package includes the following:
- Control Unit (Transmitter): The portable unit with a display and control buttons for setting temperature and programming.
- Switching Unit (Receiver): The fixed unit that connects to your heating or air conditioning system and receives commands from the control unit.
- 2 x AA Mignon Batteries (for Control Unit)
- Akwụkwọ ntuziaka onye ọrụ

Image 2.1: The EMOS P5611OT system, showing both the portable control unit with its display and buttons, and the compact switching unit.

Image 2.2: Close-up of the EMOS P5611OT control unit, highlighting its clear digital display and user interface buttons.

Image 2.3: The EMOS P5611OT switching unit, which connects directly to the heating or cooling system.
3. Atụmatụ igodo
- Nkwukọrịta ikuku: 868 MHz radio signal for flexible placement of the control unit, with a range of up to 100m in open areas.
- OpenTherm (OT) Protocol Support: Ensures efficient communication with compatible heating boilers, optimizing heating performance and energy savings.
- Enwere ike ime: Offers 9 preset programs (6 fixed, 3 customizable) for precise temperature control throughout the day and week.
- Oke okpomoku sara mbara: Adjustable temperature settings from 7 °C to 30 °C.
- Ụdị kpo oku na oyi: Compatible with both heating and air conditioning systems.
- Clear Backlit Display: Easy-to-read display showing actual and set temperatures (0 °C to 40 °C), time, and program status.
- Nchekwa oyi: Automatically activates to prevent freezing when temperatures drop too low.
- Adjustable Hysteresis: Customizable temperature differential (0.1 °C, 0.2 °C, 0.5 °C, or 1.0 °C) for fine-tuning temperature control.
- ON/OFF Function: Standard switching relay for basic control.

Image 3.1: Visual summary of key features including temperature setting range, heating/cooling modes, wireless communication, and OpenTherm support.

Image 3.2: Details on OpenTherm communication benefits, ON/OFF function, backlit display, frost protection, and temperature calibration.
4. Nhazi
4.1. Installation of the Switching Unit (Receiver)
The switching unit must be installed by a qualified electrician. Ensure the main power supply to the heating/cooling system is turned off before installation.
- Mount the switching unit in a suitable location near your heating or air conditioning appliance, away from direct heat sources or drafts.
- Connect the power supply (230 V AC) to the appropriate terminals on the switching unit.
- Connect the control wires from your heating/cooling system to the switching relay terminals (e.g., NO, COM, L) or OpenTherm terminals (OT1, OT2) as required by your appliance. Refer to your appliance's manual for specific wiring diagrams.

Foto 4.1: nso nso view of the wiring terminals on the EMOS P5611OT switching unit, showing connections for OpenTherm (OT) and standard relay (NO, COM, L).
4.2. Control Unit (Transmitter) Battery Installation
- Open the battery compartment on the back of the control unit.
- Insert the 2 x AA Mignon batteries, ensuring correct polarity (+/-).
- Close the battery compartment. The display should illuminate.

Foto 4.2: N'azụ view of the EMOS P5611OT control unit, showing the integrated stand and battery compartment.
4.3. Pairing the Units
The control unit and switching unit are typically pre-paired at the factory. If communication issues occur or if you are setting up new units, follow these general pairing steps:
- Gbaa mbọ hụ na agbanyere nkeji abụọ ahụ.
- On the switching unit, locate and press the 'ID' button (refer to Image 2.3). The indicator light may flash.
- On the control unit, access the pairing menu (refer to the full manual for specific button sequences, usually involving holding a 'P' or 'Mode' button).
- Confirm pairing on the control unit. A successful pairing will usually be indicated by a steady light on the switching unit and a confirmation message on the control unit's display.
5. Ntuziaka ọrụ
5.1. Ngosipụta gafereview
The control unit's backlit display provides essential information:
- Okpomọkụ ụlọ dị ugbu a: Displays the actual temperature detected by the control unit.
- Tọọ okpomọkụ: Shows the desired temperature you have programmed.
- Oge na Ụbọchị: Oge ugbu a na ụbọchị nke izu.
- Ihe ngosi mmemme: Shows which program (P1-P9) is currently active.
- Ụdị ọrụ: Indicates heating, cooling, or OFF.
- Ihe ngosi batrị: Alerts when batteries are low.

Image 5.1: The EMOS P5611OT control unit positioned on its integrated stand, showcasing the display and button layout.
5.2. Basic Temperature Adjustment
To manually adjust the desired temperature:
- Pịa Elu (▲) or Ala (▼) arrow buttons to increase or decrease the set temperature.
- The new setting will be temporarily active until the next programmed event or until manually overridden.

Image 5.2: Close-up of the control buttons on the EMOS P5611OT, including navigation arrows, program (P), and mode (O/C) buttons.
5.3. Programming Modes
The thermostat offers 9 programs for automated temperature control:
- 6 Fixed Programs: Pre-set schedules for common daily routines.
- Mmemme 3 a pụrụ ịhazi: Allows users to define their own temperature schedules for specific times and days.
To access and modify programs, press the P button and follow the on-screen prompts. Refer to the detailed manual for specific steps on setting custom programs.

Image 5.3: Illustration of the programmable functionality, emphasizing the ability to define temperatures for specific days and times for precise control and energy efficiency.
5.4. ON/OFF Function
The thermostat includes a basic ON/OFF function. Press the O/C button to cycle through operating modes (e.g., Heating, Cooling, OFF). In OFF mode, the system will not actively heat or cool, but frost protection may remain active.
5.5. Nchekwa oyi
When activated, frost protection ensures the temperature does not drop below a pre-set minimum (typically around 5-7°C) to prevent pipes from freezing. This feature is usually active even when the thermostat is in OFF mode.
5.6. Hysteresis Adjustment
Hysteresis (also known as differential) is the temperature range around the set point within which the heating/cooling system will not activate. This prevents rapid cycling of your appliance. You can adjust the hysteresis to 0.1 °C, 0.2 °C, 0.5 °C, or 1.0 °C through the thermostat's settings menu. A smaller hysteresis provides tighter temperature control but may lead to more frequent cycling.
6. Nlekọta
6.1. Ngbanwe batrị
When the low battery indicator appears on the control unit's display, replace the 2 x AA Mignon batteries promptly to ensure continuous operation. Refer to Section 4.2 for battery installation steps.
6.2. Nhicha
Clean the thermostat units with a soft, dry cloth. Do not use abrasive cleaners, solvents, or immerse the units in water. Ensure no moisture enters the units.
7. Nchọpụta nsogbu
- No Display on Control Unit: Check if batteries are correctly inserted and not depleted. Replace batteries if necessary.
- Sistemụ kpo oku/ajụjụ oyi anaghị aza:
- Verify the switching unit has power.
- Check the wiring connections to the heating/cooling system.
- Ensure the control unit and switching unit are properly paired (refer to Section 4.3).
- Check the operating mode (Heating/Cooling/OFF) and set temperature on the control unit.
- Ọgụgụ okpomoku na-ezighi ezi: The thermostat supports temperature calibration. Consult the full user manual for instructions on how to access and adjust temperature calibration settings.
- Poor Wireless Range: Ensure the control unit and switching unit are within the specified range (up to 100m in open areas). Large metal objects, thick walls, or other electronic devices can interfere with the radio signal. Try repositioning the control unit.
- Thermostat Cycles Too Frequently: Adjust the hysteresis setting (refer to Section 5.6) to a wider differential.
8. Nkọwapụta
| Ụdị | EMOS |
| Nọmba nlereanya | P5611OT |
| Agba | Ọcha |
| Akụkụ ngwaahịa (L x W x H) | 11.5 x 3.7 x 9.1 cm |
| Ibu Ibu | 315 g |
| Voltage (Switching Unit) | 230 volts AC |
| Na-agbanwe ugbu a | 16 (5) A |
| Ihe onwunwe | Plastic |
| Teknụzụ Njikọta | RF (868 MHz) |
| Power Source (Control Unit) | Battery powered (2 x AA Mignon) |
| Ụdị njikwa okpomọkụ | Enwere ike ime mmemme |
| Oke okpomoku nwere ike imeghari | 7 Celsius C ruo 30 Celsius |
| Oke ngosi okpomoku | 0 Celsius C ruo 40 Celsius |
| Adjustable Hysteresis | 0.1 °C, 0.2 °C, 0.5 °C, 1.0 °C |
| Atụmatụ pụrụ iche | OpenTherm Support, Frost Protection, Backlit Display |
| Product Specific Uses | Heating, Air Conditioning |
9. Akwụkwọ ikike na nkwado
For warranty information, technical support, or service inquiries, please refer to the official EMOS website or contact your local EMOS distributor. Keep your purchase receipt as proof of purchase for any warranty claims.