Hitachi WT-P200Y

Hitachi WT-P200Y Automatic Shallow Well Pump User Manual

Model: WT-P200Y

Okwu mmalite

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Hitachi WT-P200Y Automatic Shallow Well Pump. Please read this manual thoroughly before using the product and keep it for future reference.

The Hitachi WT-P200Y is an inverter-controlled automatic shallow well pump designed for reliable water supply. It features an easy-to-use control panel for convenient operation.

Ozi nchekwa

Debe ihe nchekwa nchekwa ndị a mgbe niile ka igbochi mmerụ ahụ ma ọ bụ mebie ngwaahịa a.

  • Ensure the power supply matches the pump's requirements (Single Phase 100V, 50/60Hz).
  • Do not operate the pump without water, as this can cause damage.
  • All electrical connections must be performed by a qualified electrician in accordance with local codes.
  • Debe ụmụaka na ndị ọrụ na-enweghị ikike na mgbapụta mgbe a na-arụ ọrụ.
  • Kwupu ike tupu ime mmezi ma ọ bụ nrụzi ọ bụla.
  • Chebe ọkpọkọ ahụ pụọ na okpomọkụ oyi.

Ntọala na nwụnye

Proper installation is crucial for optimal performance and longevity of your pump.

  1. Iwepu: Jiri nlezianya wepụ ọkpọkọ ahụ n'ime ihe e ji ekpuchi ya. Lelee ma ọ bụrụ na e mebisịrị ihe ọ bụla e ji ebuga ya.
  2. Nkwanye: Install the pump on a stable, level surface in a well-ventilated area, protected from direct sunlight, rain, and freezing. Ensure adequate space for maintenance.
  3. Njikọ ọkpọkọ:
    • Connect the suction pipe (25mm, Rc1) to the pump's suction inlet. Ensure an airtight seal to prevent air leaks.
    • Connect the discharge pipe (25mm, Rc1) to the pump's discharge outlet.
    • Use appropriate fittings and sealants to prevent leaks.
  4. Ndozi: Before initial operation, the pump must be primed.
    • Remove the priming plug (if applicable) or fill the pump casing with water until full.
    • Replace the plug securely.
  5. Njikọ eletrik: Connect the power cord to a grounded 100V, 50/60Hz power outlet. Ensure the circuit is protected by a suitable circuit breaker.
Hitachi WT-P200Y Pump Dimensions and Performance Curve

Foto 1: Diagram showing the Hitachi WT-P200Y pump's dimensions and performance curve. The diagram illustrates the pump's physical measurements, including discharge and suction outlets, and a graph detailing the relationship between total head (m) and discharge volume (L/min) under various operating pressures and suction heights. This helps in planning installation and understanding operational limits.

Ntuziaka ọrụ

The WT-P200Y features an easy-to-use control panel for selecting operating modes.

  1. Mmalite mbụ:
    • After ensuring proper installation and priming, plug in the pump.
    • The pump will automatically start when water is demanded (e.g., opening a faucet) and stop when demand ceases.
  2. Selecting Operating Pressure Modes: The control panel allows selection of different pressure modes. Refer to the panel diagram for specific settings.
    • Ụkpụrụ ọkọlọtọ: Provides balanced pressure for general household use.
    • High Pressure Mode: For applications requiring stronger water pressure.
    • Low Pressure Mode: For situations where reduced pressure is desired.
  3. Ọrụ akpaaka: The pump is designed for automatic operation. It will detect water demand and adjust its output accordingly, thanks to its inverter technology.
Hitachi WT-P200Y Control Panel and Pressure Modes

Foto 2: Image displaying the easy-to-use control panel of the Hitachi WT-P200Y pump. The panel allows users to select from various operating pressure modes (Standard, High, Low) to suit different water usage requirements. This image also highlights the wear-resistant elastic casing technology.

Nlekọta

Ndozi mgbe niile na-eme ka ọkpọkọ gị dị ogologo ma rụọ ọrụ nke ọma.

  • Nlele anya kwa ọnwa:
    • Inspect for any visible leaks around connections.
    • Check for unusual noises or vibrations during operation.
  • Nyocha kwa afọ:
    • Clean any debris from the pump's exterior.
    • Verify the condition of the power cord and plug.
    • For internal component checks, it is recommended to contact a qualified service technician.
  • Oge oyi (maka ihu igwe oyi):
    • Drain all water from the pump and piping to prevent freezing damage.
    • Store the pump in a warm, dry place if possible, or insulate it thoroughly.
Hitachi WT-P200Y Impeller and Casing Technology

Foto 3: Nke ime view of the Hitachi WT-P200Y pump, highlighting the innovative Y-shaped impeller design and the wear-resistant elastic casing. This design contributes to the pump's high lift capability and durability, reducing wear from sand and debris in the water.

Nchọpụta nsogbu

Rụtụ aka na ngalaba a maka okwu nkịtị na azịza ha.

Nsogbu Ihe nwere ike ime Ngwọta
Mgbapụta anaghị ebido. No power supply; tripped circuit breaker; motor overload. Check power connection; reset circuit breaker; allow motor to cool down.
Pump runs but no water is delivered. Pump not primed; air leak in suction line; low water level in well; clogged suction filter. Re-prime the pump; check all suction connections for leaks; verify well water level; clean suction filter.
Mmiri dị ala. Partial clog in piping; incorrect pressure mode selected; worn impeller. Check and clear piping; select higher pressure mode on control panel; contact service for impeller inspection.
Pump cycles frequently. Small leak in plumbing system; pressure switch malfunction. Inspect plumbing for leaks; contact service for pressure switch check.

Nkọwapụta

Njirimara Nkọwa
Nlereanya WT-P200Y
Ụdị Hitachi
Isi Iyi Ike Ụdị eriri ike
Voltage 100 Volts (Single Phase)
Ugboro ugboro 50/60Hz
Enyere mmepụta 200W
Wattage (Power Consumption) 440 W
Akụkụ ngwaahịa (L x W x H) 35.6 x 37.6 x 49 cm
Ibu ngwaahịa 14 n'arọ
Ọnụego nfe kacha 35 lita / nkeji
Max ebuli elu 12 mita
Agba Agba ntụ
Ngwa gụnyere Akwụkwọ ntuziaka
Hitachi WT-P200Y Automatic Shallow Well Pump

Foto 4: A izugbe view of the Hitachi WT-P200Y Automatic Shallow Well Pump. This image provides an overall visual reference of the product's design and appearance.

Akwụkwọ ikike na nkwado

Ngwaahịa a na-abịa na a Akwụkwọ ikike onye nrụpụta afọ 1 site na ụbọchị ịzụrụ. Biko dowe ihe akaebe nke ịzụrụ ihe maka akwụkwọ ikike.

For technical support, service, or warranty inquiries, please contact Hitachi Global Life Solutions customer service. Contact information can typically be found on the official Hitachi websaịtị ma ọ bụ na akwụkwọ ịzụrụ ihe gị.

Mara: Nrụzi ma ọ bụ mgbanwe na-enwetaghị ikike ga-emebi akwụkwọ ikike.