1. Okwu mmalite
This manual provides comprehensive instructions for the installation, operation, and maintenance of your 2GIG Z-Wave 700 Programmable Thermostat, Model 2GIG-STZ-1. This device allows for remote control of your heating and air conditioning systems via a Z-Wave network, in addition to direct control from the thermostat unit.
The 2GIG-STZ-1 thermostat is compatible with most modern HVAC systems, including standard Gas/Electric (2-stage kpo oku, 2-stage cooling) and Heat Pump systems (3-stage kpo oku, 2-stage cooling), with support for humidifiers and dehumidifiers.

Foto 1: N'ihu view of the 2GIG Z-Wave 700 Programmable Thermostat, displaying current temperature, fan status, and time.
Akụkụ ndị bụ isi:
- Njikwa Z-Wave: Seamless integration with smart home systems for remote access.
- Ndakọrịta nke ukwuu: Supports standard gas/electric, heat pump, and humidifier/dehumidifier systems.
- Nwụnye dị mfe: Designed for straightforward replacement of existing thermostats.
- Isi Iyi Ike Abụọ: Operates on 4 AA batteries or 24VAC power from your HVAC system.
- Kpochapụ ihe ngosi: Large, easy-to-read LCD for temperature control and monitoring.
2. Ozi nchekwa
Please read all instructions carefully before installing or operating this thermostat. Failure to follow these instructions could result in property damage, injury, or death.
- Nchekwa Eletriki: Always turn off power to the HVAC system at the circuit breaker before installing or servicing the thermostat.
- Voltage ndakọrịta: This thermostat is designed for 24VAC systems only. It is NOT compatible with 120/240 VAC systems.
- Nwụnye batrị: If powering the thermostat via 24VAC, do not install AA batteries. Batteries are for backup power only if 24VAC is not available or desired.
- Nwụnye ọkachamara: Ọ bụrụ na obi adịghị gị mma maka akụkụ ọ bụla nke usoro nrụnye ahụ, gakwuru ọkachamara HVAC ruru eru.
3. Ihe ngwugwu
Chọpụta na ihe niile dị na ngwugwu:
- 2GIG Z-Wave 700 Programmable Thermostat (Model 2GIG-STZ-1)
- 4 x AA batrị
- Ngwa mgbakwunye (skru na arịlịka mgbidi)
- Akwụkwọ ntuziaka nwụnye (akwụkwọ a)
- Ntuziaka mmalite ngwa ngwa
4. Nwụnye
4.1. Na-akwadebe maka nwụnye
- Turn off power to your heating and cooling system at the main circuit breaker.
- Remove your old thermostat's cover. Take a picture of the wiring connections for reference.
- Dee waya ọ bụla akara na mkpụrụedemede njedebe kwekọrọ na thermostat ochie gị.
- Kwụpụ waya ndị ahụ ma wepụ efere ihe e ji etinye thermostat ochie ahụ.
4.2. Mounting the Back Panel
The back panel of the 2GIG-STZ-1 thermostat serves as the mounting base and wiring terminal.
- Feed the wire cable from the wall through the access hole in the new mounting plate.
- Use the provided wall anchors and two Phillips screws to secure the back panel to the wall.
- Ensure the back panel is level for proper aesthetic alignment.

Figure 2: Illustration of mounting the back panel, showing wire access and screw locations.
4.3. Ịkpọnye Thermostat ahụ
Connect the labeled wires to the corresponding terminals on the thermostat's back panel. Refer to your old thermostat's wiring diagram and the labels you made. The 2GIG-STZ-1 supports the following configurations:
- Standard Gas/Electric HVAC: Ruo 2-stage kpo oku, 2-stage jụrụ.
- Heat Pump HVAC: Ruo 3-stage kpo oku, 2-stage jụrụ.
- Humidifier/Dehumidifier Support: Dedicated terminals available.
For 24VAC power, ensure both "R" and "C" wires are connected. If a "C" wire is not available, the thermostat can be powered by 4 AA batteries, but it will not repeat Z-Wave signals in your network.
4.4. Ịgbakwunye ihu ihu
Once wiring is complete, attach the thermostat's front panel to the mounted back panel.
- Align the front panel with the back panel.
- Gently press the front panel onto the back panel until it snaps securely into place around all edges.

Figure 3: Illustration of attaching the front panel to the back panel, showing the snap-together mechanism.
After the front panel is attached, restore power to your HVAC system at the circuit breaker.
5. Ntuziaka ọrụ
5.1. Ịnye Thermostat ike
The thermostat can be powered by 24VAC from your HVAC system (if "R" and "C" wires are connected) or by four (4) AA batteries. If 24VAC is supplied, batteries are not required for operation but can serve as a backup. If only battery-powered, the thermostat will not function as a Z-Wave repeater.
5.2. Njikwa ntọala
The thermostat features a clear LCD display and intuitive buttons for control:
- bọtịnụ FAN: Cycles through fan modes (Auto, On).
- Bọtịnụ MODE: Cycles through system modes (Heat, Cool, Auto, Off, Em Heat).
- Àkụ elu/ala: Adjusts the temperature setpoint.
5.3. Ịgbanwe Okpomọkụ
Pịa Up or Ala arrow buttons to increase or decrease the desired temperature setpoint. The display will show the new setpoint temporarily.
5.4. Z-Wave Network Integration
To integrate the thermostat into your Z-Wave network, refer to your Z-Wave hub's instructions for adding new devices. The 2GIG-STZ-1 is a Z-Wave 700 series device, offering enhanced range and battery life. Once paired, you can control the thermostat remotely via your Z-Wave smart device or hub interface.
Mara: For optimal Z-Wave performance and to function as a Z-Wave repeater, the thermostat should be powered by 24VAC.
6. Nlekọta
6.1. Ihicha Thermostat
Iji hichaa thermostat, jiri nwayọọ hichaa mpụta ahụ jiri nro dị nro, damp cloth. Do not use abrasive cleaners, solvents, or spray cleaners directly onto the thermostat, as this may damage the unit or its electronic components.
6.2. Ngbanwe batrị
If your thermostat is battery-powered, replace the four (4) AA batteries when the low battery indicator appears on the display. Ensure to use fresh, high-quality alkaline batteries. If the thermostat is 24VAC powered, battery replacement is not typically required for operation, but batteries can be installed for backup power.
- Carefully remove the front panel of the thermostat from the back panel.
- Wepu batrị AA ochie.
- Insert four new AA batteries, ensuring correct polarity (+/-).
- Reattach the front panel to the back panel until it snaps securely.
7. Nchọpụta nsogbu
If you encounter issues with your 2GIG-STZ-1 thermostat, refer to the following common problems and solutions:
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Thermostat has no power/blank display. | No 24VAC power; dead batteries; incorrect wiring. | Check circuit breaker for HVAC system. Replace AA batteries if battery-powered. Verify "R" and "C" wire connections. |
| Sistemụ HVAC anaghị anabata thermostat. | Incorrect wiring; system mode set to "Off"; Z-Wave communication issue. | Double-check wiring. Ensure system mode is set to "Heat", "Cool", or "Auto". Re-pair with Z-Wave network if controlling remotely. |
| Temperature swing is too wide. | Thermostat differential settings. | Consult the advanced settings menu (if available) or your Z-Wave controller for options to adjust temperature differential. This setting controls how far the temperature deviates from the setpoint before the system activates. |
| Cannot connect to Z-Wave network. | Thermostat too far from hub; interference; incorrect pairing procedure. | Ensure thermostat is within range of the Z-Wave hub or a repeater. Follow Z-Wave hub's specific instructions for inclusion/exclusion. Ensure thermostat is 24VAC powered to act as a repeater. |
8. Nkọwapụta
| Njirimara | Nkọwa |
|---|---|
| Nọmba nlereanya | 2GIG-STZ-1 (also known as 2GIG-STZ1-345) |
| Ndakọrịta | 24VAC 3H/2C non-heat pump/heat pump systems with humidifier/dehumidifier support. Not compatible with 120/240 VAC systems. |
| Room Temperature Measurement Scale | Fahrenheit / Celsius (user selectable) |
| Oke okpomọkụ ụlọ | 32 ruo 122 degrees F (0 ruo 50 degrees C) |
| Okpomọkụ ziri ezi | +/- 1 degrees F (0.5 degrees C) |
| Heat Set Point Range | 32 - 90 degrees F (0 - 32 degrees C) |
| Cool Set Point Range | 61 - 122 degrees F (16 - 50 degrees C) |
| Nhazi mkpebi | 1 degrees F (0.5 degrees C) |
| Njikwa Fans | Akpaaka/ Gbanwuo |
| Ịnye ọkụ | AC: 18-26VAC 60Hz (R and C); 4x AA size battery (6VDC) |
| Oke okpomoku na-arụ ọrụ | 32 ruo 122 degrees F (0 ruo 50 degrees C) |
| Iru mmiri na-arụ ọrụ | 10-90 percent Non-Condensing |
| Akụkụ (H x W x D) | 5.75 x 4.5 x 1 inch (14.6 x 11.4 x 2.5 cm) |
| Ibu | 1.06 lbs (0.48 n'arọ) |
| Njikọta | Z-Wave (usoro 700) |
| Ụdị ngosi | LCD na azụ azụ |
9. Akwụkwọ ikike Ozi
The 2GIG Z-Wave 700 Programmable Thermostat (Model 2GIG-STZ-1) comes with a Akwụkwọ ikike afọ 1 nwere oke from the manufacturer. Please retain your proof of purchase for warranty claims. For specific terms and conditions, refer to the warranty documentation included with your product or contact 2GIG customer support.
10. Nkwado ndị ahịa
For further assistance, technical support, or warranty inquiries, please contact 2GIG customer support. You may also refer to the support resources provided by your Z-Wave hub manufacturer for integration-specific questions.
Mara: Manufacturer support policies may vary. Access to detailed manuals or direct support might be restricted to authorized dealers or installers in some cases.