This manual provides essential information for the safe and efficient operation of the COTEK SE200-248 Pure Sine Wave Inverter. Please read thoroughly before installation and use to ensure optimal performance and longevity of your device.

The COTEK SE200-248 is a compact and efficient 200W pure sine wave inverter designed to convert 48VDC power from batteries into stable 230VAC power, suitable for sensitive electronic equipment. It features a standard SCHUKO outlet for convenient connection of AC devices.

COTEK SE200-248 Pure Sine Wave Inverter, front-top view.

Figure 1: COTEK SE200-248 Pure Sine Wave Inverter.

Ozi nchekwa

Ntuziaka nchekwa dị mkpa: Always follow these guidelines to prevent injury or damage to the inverter and connected devices.

  • Read all instructions carefully before operating the inverter.
  • Do not expose the inverter to rain, moisture, or extreme temperatures. Operate within specified environmental conditions.
  • Ensure proper ventilation around the inverter to prevent overheating. Do not block air vents.
  • Connect the inverter only to a DC power source within the specified voltage range (48VDC nominal). Incorrect voltage nwere ike imebi ihe.
  • Emeghela inverter casing. Enweghị akụkụ ndị ọrụ ga-arụ ọrụ n'ime. Kpọtụrụ ndị ọrụ ruru eru ọrụ niile.
  • Always disconnect the DC power source before performing any maintenance, cleaning, or moving the inverter.
  • Ensure the inverter is properly grounded before operation.

Ntọala na nwụnye

Proper installation is crucial for the performance, efficiency, and safety of your inverter.

1. Ịhọrọ ebe

Select a cool, dry, and well-ventilated area for installation. Avoid direct sunlight, heat sources, and areas with excessive dust, moisture, or corrosive fumes. Ensure sufficient clearance (at least 6 inches) around the inverter for proper airflow and cooling.

2. DC Input Connection

Connect the DC input cables to the inverter's terminals. Ensure correct polarity: positive (+) to the red terminal and negative (-) to the black terminal. Use appropriately sized cables to minimize voltage drop and ensure efficient power transfer. Secure all connections tightly.

N'azụ view of COTEK SE200-248 inverter showing DC input terminals, cooling fan, and remote port.

Ọgụgụ 2: N'azụ view of the COTEK SE200-248 inverter, showing DC input terminals and cooling fan.

3. Nda ala

Connect the chassis ground terminal of the inverter to a reliable earth ground. This is essential for safety and to prevent electrical shock. Use a dedicated ground wire of appropriate gauge.

4. AC Output Connection

The inverter features a SCHUKO outlet for AC output. Plug your AC devices directly into this outlet. Ensure the total power consumption of all connected devices does not exceed the inverter's rated output of 200W. Overloading the inverter can cause it to shut down or be damaged.

N'ihu view of COTEK SE200-248 inverter showing SCHUKO outlet, power switch, and status indicator.

Foto 3: N'ihu view of the COTEK SE200-248 inverter, showing the SCHUKO AC outlet and controls.

Ntuziaka ọrụ

Ịgbanyụ/ Gbanyụọ

  1. Ensure all DC and AC connections are secure before powering on.
  2. To turn on the inverter, flip the power switch to the "ON" position. The status indicator light will illuminate, indicating normal operation.
  3. To turn off the inverter, flip the power switch to the "OFF" position. Disconnect AC loads before powering off for best practice.

Njikwa anya (Nhọrọ)

The inverter supports an optional remote ON/OFF control via the green terminal block. Connect a compatible remote switch or control system to this terminal. Refer to the remote control's specific instructions for connection and operation details.

Output Frequency and Power Saving Mode

The output frequency (50Hz or 60Hz) and power saving mode can be selected using the DIP switches located on the front panel. Consult the detailed specifications or the inverter's label for specific switch configurations to match your regional requirements or power saving preferences.

Nlekọta

The COTEK SE200-248 inverter is designed for minimal maintenance. Regular checks will ensure its continued reliable operation.

  • Nhicha: Periodically clean the exterior of the inverter with a dry, soft cloth. Do not use liquid cleaners, solvents, or abrasive materials, as these can damage the casing ma ọ bụ ihe ndị dị n'ime.
  • Igwe ikuku: Ensure the ventilation openings and cooling fan (if present) are clear of dust and debris. Blocked vents can lead to overheating and reduced performance. Use compressed air to clear dust if necessary.
  • Njikọ: Regularly check all electrical connections (DC input, AC output, and ground) to ensure they are tight and free from corrosion. Loose connections can cause power loss or overheating.

Nchọpụta nsogbu

This section provides solutions to common issues you might encounter with your inverter.

NsogbuIhe nwere ike imeNgwọta
Inverter anaghị agbanyụNo DC input power; Low battery voltage; Blown DC input fuse; Loose connections.Lelee njikọ batrị na voltage (must be within specified range); Replace fuse if necessary (ensure correct rating); Tighten all electrical connections.
No AC output / Inverter shuts downOverload condition; Over-temperature; Short circuit on AC output; Low input voltage.Reduce the total power consumption of connected AC devices; Allow inverter to cool down in a well-ventilated area; Check for short circuits in connected devices or wiring; Recharge or replace battery.
Fan running constantly or loudlyHigh internal temperature; Heavy load.Ensure adequate ventilation around the inverter; Reduce the connected load if possible. This is often normal operation under load.

Nkọwapụta

Detailed technical specifications for the COTEK SE200-248 Pure Sine Wave Inverter:

  • Ụdị: COTEK SE200-248
  • Ike mmepụta: 200W Continuous Pure Sine Wave
  • Ntinye Voltage: 48VDC (Operating range: 40VDC to 60VDC)
  • Mmepụta Voltage: 230VAC
  • Ugboro mmepụta: 50Hz / 60Hz (Selectable via DIP switch)
  • Mmepụta Waveform: Okpokoro nke Sine
  • Okpomọkụ arụ ọrụ: -20°C ruo 60°C (-4°F ruo 140°F)
  • Akụkụ: Ihe dịka 7 x 6 x 3 sentimita (17.8 x 15.2 x 7.6 cm)
  • Arọ: Ihe dị ka 4 pound (1.8 n'arọ)
  • Nchedo: Input Reverse Polarity (Fuse), Input Under Voltage, Input Over Voltage, Output Short Circuit, Output Overload, Over Temperature
  • Asambodo: CE, FCC, E13 approved

Ozi akwụkwọ ikike

For detailed warranty terms and conditions, please refer to the warranty card included with your product packaging or visit the official COTEK website. Keep your original purchase receipt as proof of purchase for any warranty claims.

Nkwado ndị ahịa

If you encounter any issues or have questions not covered in this manual, please contact COTEK customer support for assistance.

Websaịtị: www.cotek.com.tw

Email: support@cotek.com

Akwụkwọ ndị emetụtara - SE200-248

Tupuview Ntuziaka Onye Ọrụ nke COTEK SE Series Pure Sine Wave Inverter (200W, 350W, 400W)
Comprehensive user manual for the COTEK SE Series Pure Sine Wave Inverters, covering models 200W, 350W, and 400W. This guide provides detailed information on safety precautions, product features, electrical specifications, installation procedures, operation, maintenance, troubleshooting, and warranty details.
Tupuview Akwụkwọ ntuziaka onye ọrụ COTEK SK Series 1500W Pure Sine Wave Inverter
Akwụkwọ ntuziaka zuru oke maka onye ọrụ maka COTEK SK Series 1500W Pure Sine Wave Inverter, nke na-ekpuchi nchekwa, atụmatụ, nkọwapụta, ntinye, ọrụ, mmezi, na nsogbu nsogbu. Na-enye nduzi zuru ezu maka ojiji na nlekọta kwesịrị ekwesị.
Tupuview COTEK SR-1600 PLUS Rack Mount Pure Sine Wave Inverter: Quick Introduction
Nkenke nkenkeview of the COTEK SR-1600 PLUS series rack-mount pure sine wave inverters, detailing specifications, product appearance, installation, and warranty information.
Tupuview Akwụkwọ ntuziaka onye ọrụ COTEK SPT dị ọcha Sine Wave Inverter - SPT1200/2000/3000
Akwụkwọ ntuziaka onye ọrụ zuru oke maka COTEK SPT Series Pure Sine Wave Inverters (SPT1200, SPT2000, SPT3000). Na-ekpuchi ntuziaka nchekwa, njirimara arụ ọrụ, nkọwapụta, nrụnye, mmezi, nzikọrịta ozi RS-485, nchọpụta nsogbu na ozi akwụkwọ ikike.
Tupuview Akwụkwọ ntuziaka onye ọrụ COTEK SK Series dị ọcha Sine Wave Inverter
Akwụkwọ ntuziaka onye ọrụ a na-enye ntụzịaka zuru oke maka COTEK SK Series Pure Sine Wave Inverters. Ọ na-ekpuchi ozi nchekwa dị mkpa, njirimara ngwaahịa, nkọwapụta ọkụ eletrik na igwe zuru ezu, ntuziaka nwụnye, usoro arụmọrụ, usoro nchọpụta nsogbu, ndụmọdụ mmezi, yana nkọwa akwụkwọ ikike maka ụdị SK700, SK1000, SK1500, SK2000, na SK3000.
Tupuview Akwụkwọ ntuziaka onye ọrụ COTEK SK120, SK200, SK350 Series Pure Sine Wave Inverter
Akwụkwọ ntuziaka onye ọrụ a na-enye ozi zuru ezu na usoro COTEK SK120, SK200 na SK350 dị ọcha sine wave inverters, mkpuchi mkpuchi, njirimara, ntinye, ọrụ, nchọpụta nsogbu na akwụkwọ ikike.