This manual provides essential instructions for the safe and efficient operation, installation, and maintenance of your Airwell 7MB021061 Mobile Air Conditioner. Please read this manual thoroughly before using the appliance and retain it for future reference.

Foto 1: N'ihu view of the Airwell 7MB021061 Mobile Air Conditioner. This image displays the compact, white unit with the Airwell logo subtly embossed on the front panel. A handle is visible on the top right side for portability, and a grey exhaust port is partially visible on the right side.
2. Akụrụngwa Ngwaahịa
- Nrụ ọrụ dị iche iche: Offers cooling-only operation.
- Enwere ike ibugharị: Equipped with wheels and integrated carrying handles for easy movement.
- Njikwa anya: Includes a remote control for convenient operation.
- Windo Window: Supplied with an installation kit suitable for standard windows and walls.
- Dehumidifier Function: Capable of reducing humidity levels in the room.
- "I Feel" Comfort: Features a temperature sensor located in the remote control for precise temperature regulation based on the remote's location.
- Igwe nju oyi na-adị mma: Utilizes R290 refrigerant, which has a very low environmental impact.
- Ngosipụta njikwa: An integrated control display is present on the unit.
- Condensate Reduction: Designed with condensate evaporation on the exchanger.
3. Ntọala na nwụnye
Proper setup is crucial for optimal performance and safety. Follow these general guidelines:
- Iwepu: Jiri nlezianya wepụ ihe mkpuchi ikuku na ihe niile dị na ngwugwu ahụ. Debe ngwugwu ahụ maka nchekwa ma ọ bụ ibuga ya n'ọdịnihu.
- Nkwanye: Position the unit on a flat, stable surface, ensuring adequate clearance around the unit for proper airflow. Avoid placing it near heat sources or in direct sunlight.
- Nwụnye Hose Exhaust:
- Attach the exhaust hose to the designated outlet on the rear of the air conditioner.
- Utilize the provided window kit to securely vent the hot air outside through a window or wall opening. Ensure the hose is as straight and short as possible to maximize efficiency.
- Njikọ ike: Tinye eriri ọkụ n'ime oghere eletrik gbadoro ụkwụ. Gbaa mbọ hụ na voltage dakọtara na nkọwapụta nke unit ahụ.
4. Ntuziaka ọrụ
The Airwell 7MB021061 can be operated via the control display on the unit or the included remote control.
4.1. Ọrụ Panel Control
Refer to the icons and buttons on the unit's control display for direct adjustments to settings such as power, mode selection (Cool, Dehumidify), fan speed, and temperature.
4.2. Remote Control Ọrụ
The remote control provides full functionality from a distance. Insert batteries as indicated in the remote's compartment.
- Bọtịnụ ike: Gbanyụọ ma ọ bụ gbanyụọ unit ahụ.
- Nhọrọ ụdị: Cycle through available modes (Cool, Dehumidify).
- Ndozi okpomọkụ: Jiri akụ elu/ala ka ịtọọ okpomọkụ achọrọ.
- Ọsọ onye ofufe: Adjust the fan speed (Low, Medium, High).
- "I Feel" Function: Activate this function for enhanced comfort. The remote control's built-in sensor will measure the ambient temperature at its location and adjust the air conditioner's operation to maintain the set temperature around the remote. Ensure the remote is placed in a central area of the room.
5. Nlekọta
Nlekọta anya mgbe niile na-eme ka ogologo ndụ na arụmọrụ nke ikuku ikuku gị dị ogologo.
- Nchacha ihe nzacha: The air filter should be cleaned regularly (e.g., every two weeks, depending on usage) to prevent dust buildup and maintain airflow. Refer to the unit's specific instructions for filter removal and cleaning.
- Nchacha mpụta: Jiri nwayọ hichaa mpụta nke otu ahụ, damp akwa . Ejila kemịkalụ siri ike ma ọ bụ ihe mkpocha abrasive.
- Nchekwa: Before long-term storage, ensure the unit is thoroughly drained of any accumulated water. Clean the filters and store the unit in a dry, cool place, preferably in its original packaging.
6. Nchọpụta nsogbu
If you encounter issues with your air conditioner, consult the following basic troubleshooting steps:
- Nkeji anaghị agbanwu: Check if the power cord is securely plugged into a functional outlet. Ensure the unit's power button is pressed and the remote control batteries are not depleted.
- Njụjụ ezughị oke: Verify that the exhaust hose is properly installed and venting hot air outside. Check if air filters are clean and not obstructed. Ensure windows and doors are closed to prevent warm air entry.
- Mkpọtụ na-adịghị ahụkebe: Ensure the unit is on a flat, stable surface. Check for any obstructions around the fan or air inlets/outlets.
- Mgbapu mmiri: Ensure the unit is level. If the unit has a drain plug, check if it is securely closed, unless continuous drainage is intended.
Maka nsogbu ndị na-adịgide adịgide, kpọtụrụ onye na-ahụ maka ndị ahịa ma ọ bụ ọkachamara teknụzụ ruru eru.
7. Nkọwapụta
| Njirimara | Uru |
|---|---|
| Nọmba nlereanya | 7MB021061 |
| Nominal Cooling Power | 3.52 kW |
| Ike | 3520 W |
| Oriri ike | 1.357 kW |
| Ugbu a | 5.9 A |
| Operating Limits (Dry Bulb) | 17°C/35°C |
| Sound Pressure Level (PV/MV/GV at 1m) | 50/51/52 dB(A) |
| Ọkwa ike ụda | 63 dB(A) |
| Airflow (PV/MV/GV) | 355/370/420 m³/h |
| Dehumidification ikike | 1.8 l/h |
| Klas arụmọrụ ike | A+ |
| Igwe nju oyi | R290 |
| Obosara | 467 mm |
| Ogologo | 765 mm |
| Omimi | 397 mm |
| Ibu | 33 n'arọ |
8. Akwụkwọ ikike na nkwado
The Airwell 7MB021061 Mobile Air Conditioner comes with a 1-afọ akwụkwọ ikike site na ụbọchị ịzụrụ.
For warranty claims, technical support, or service inquiries, please contact your retailer or the official Airwell customer service. Ensure you have your proof of purchase and the product model number (7MB021061) available when contacting support.