Tektronix TBS2074B

Akwụkwọ ntuziaka onye ọrụ Tektronix TBS2074B Digital Oscilloscope

Model: TBS2074B | Brand: Tektronix

1. Okwu mmalite

The Tektronix TBS2000B series digital oscilloscopes are designed to provide high-level signal display and measurement, which are critical functions for any oscilloscope. The TBS2074B model, with its 70MHz bandwidth and 4 channels, offers an intuitive user experience and powerful analysis capabilities. This manual provides essential information for setting up, operating, maintaining, and troubleshooting your TBS2074B oscilloscope.

Tektronix TBS2074B Digital Oscilloscope front view

Foto 1.1: N'ihu view of the Tektronix TBS2074B Digital Oscilloscope.

2. Atụmatụ igodo

The TBS2074B oscilloscope is equipped with features designed to enhance usability and measurement accuracy:

3. Nhazi

3.1 Nwepu

Carefully remove the oscilloscope and all accessories from the packaging. Verify that all components listed in the packing list are present and undamaged. Retain the original packaging for future transport or storage.

3.2 Ijikọ ike

Connect the provided power cord to the AC input on the rear panel of the oscilloscope and then to a suitable power outlet. Ensure the power source meets the voltage and frequency requirements specified on the device label.

N'azụ view of Tektronix TBS2074B showing power input and connectivity ports

Figure 3.1: Rear panel of the oscilloscope with power input and connectivity ports.

3.3 Ike mbido

Press the power button located on the front panel. The oscilloscope will perform a self-test and then display the main waveform screen. Allow a few moments for the system to fully initialize.

4. Ọrụ

4.1 Interface onye ọrụ gafereview

The TBS2074B features a large 9-inch display and an intuitive front panel with dedicated controls for vertical, horizontal, and trigger settings. Navigation buttons and a rotary knob allow for easy menu access and parameter adjustment.

Tektronix TBS2074B display showing 15 horizontal divisions

Figure 4.1: The oscilloscope display highlighting the 15 horizontal divisions for extended signal view.

4.2 Nha Ndị Dị Mkpa

To perform a basic measurement:

  1. Connect the appropriate probe to one of the input channels (CH1-CH4) on the front panel.
  2. Connect the probe tip to the circuit point you wish to measure.
  3. Adjust the vertical scale (Volts/Div) and horizontal scale (Sec/Div) knobs to display the waveform clearly.
  4. Use the Trigger controls to stabilize the waveform on the screen.
  5. Press the 'Measure' button to access automatic measurement options.
Tektronix TBS2074B with probes connected to input channels

Figure 4.2: Connecting probes to the oscilloscope input channels.

4.3 Ọrụ dị elu

The TBS2074B offers advanced analysis tools:

Tektronix TBS2074B display showing automatic measurement menu

Figure 4.3: The automatic measurement selection menu on the oscilloscope display.

Tektronix TBS2074B display showing waveform with search and mark function in use

Figure 4.4: Waveform display demonstrating the search and mark function.

5. Njikọta

The TBS2074B offers various connectivity options for data transfer and remote control:

Close-up of the rear panel of Tektronix TBS2074B showing USB and Ethernet ports

Ọgụgụ 5.1: nso nso view of the rear panel connectivity ports.

Tektronix TBS2074B connected to a laptop via USB cable

Figure 5.2: The oscilloscope connected to a laptop for data transfer or remote control.

6. Nlekọta

6.1 Nhicha

To maintain the performance and appearance of your oscilloscope, regularly clean the exterior surfaces. Use a soft, damp cloth with a mild detergent. Avoid abrasive cleaners or solvents that could damage the plastic components or display.

6.2 Nchekwa

When not in use, store the oscilloscope in a clean, dry environment, away from direct sunlight and extreme temperatures. If storing for extended periods, it is recommended to use the original packaging or a protective case.

7. Nchọpụta nsogbu

This section provides solutions to common issues you might encounter with your TBS2074B oscilloscope.

NsogbuIhe nwere ike imeNgwọta
Enweghị ikePower cord not connected; Power outlet fault; Internal fuse blownCheck power cord connection; Test power outlet; Contact service for fuse replacement
Enweghị ụdị ebili mmiri egosiriProbe not connected; Incorrect vertical/horizontal settings; Trigger not set correctlyEnsure probe is connected; Adjust Volts/Div and Sec/Div; Adjust trigger level or mode
Ụdị ebili mmiri na-adịghị akwụsi ikeIncorrect trigger source or level; Signal noiseVerify trigger source and adjust trigger level; Use averaging or bandwidth limit to reduce noise

If you encounter issues not covered here, or if the suggested solutions do not resolve the problem, please contact Tektronix customer support.

8. Nkọwapụta

Detailed technical specifications for the Tektronix TBS2074B Digital Oscilloscope:

NkọwapụtaUru
Onye nrụpụtaTektronix
Nọmba nlereanyaTBS2074B
Bandwit70 MHz (Upgradeable to 200 MHz with option)
Ọwa analog4
Max Sample Ọnụ2 GS/s (half channel), 1 GS/s (all channels)
Ogologo ndekọ5 M points
Ngosipụta9-inch WVGA Color Display
Automatic MeasurementsỤdị 32
Nyochaa InterfaceTekVPI
NjikọtaUSB 2.0 Host (front), USB 2.0 Device (rear), 10/100BASE-T Ethernet, Wi-Fi
Ibu Ibu3 kilogram
Akụkụ ngwugwu50 x 40 x 26 cm
Ngwa gụnyereStandard Accessory KIT
Batrị ejiriMba
First Available Date (Amazon.co.jp)2020/5/11

9. Akwụkwọ ikike na nkwado

Tektronix products are designed for reliability and performance. For information regarding warranty coverage, technical support, and service, please refer to the official Tektronix website or contact your local Tektronix representative. Keep your purchase receipt as proof of purchase for warranty claims.

For further assistance, visit the official Tektronix support page: www.tek.com/support