1. Okwu mmalite
This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your Hessaire M150 Portable Evaporative Cooler. This unit is designed to provide effective cooling in various environments, including shops, garages, and outdoor covered areas.
The M150 features a high-visibility green trim and power cord, adjustable front louvers for multi-directional airflow, and an oscillation feature to broaden air flow coverage. It supports continuous water fill with an included hose adapter and utilizes a proprietary swept-wing prop design for optimal airflow. It is most efficient in low humidity climates and can cool up to 950 square feet with 3100 CFM.
2. Ozi nchekwa dị mkpa
Biko gụọ ntuziaka niile nke ọma tupu ị rụọ ọrụ na ngwaọrụ ahụ. Ọ bụrụ na ị gbasoghị ntuziaka ndị a, ọ nwere ike ibute nkụchi eletriki, ọkụ, ma ọ bụ nnukwu mmerụ ahụ.
- Gbaa mbọ hụ na etinyere unit ahụ n'elu kwụsiri ike ma dịkwa larịị.
- Do not operate the cooler with a damaged cord or plug.
- Ejila akụkụ, eriri, ma ọ bụ nkwụnye na mmiri ma ọ bụ ihe mmiri ndị ọzọ.
- Unplug the unit from the power outlet before cleaning, performing maintenance, or when not in use.
- Debe ụmụaka na anụ ụlọ n'ebe a na-arụ ọrụ.
- Ensure proper ventilation. The cooler must be positioned in front of an open window or door if it is to operate effectively. Always ensure that there is another open window or door through which the air can exhaust from the room.
- Akwụsịla ntinye ikuku ma ọ bụ ọnụ ụzọ.
- Jiri naanị ụzọ mgbakwasị ụkwụ dabara adaba.
- Atụmatụ ịdọ aka ná ntị 65: Ngwaahịa a nwere ike ịnwe kemịkalụ mara steeti California na-ebute ọrịa kansa na ntụpọ ọmụmụ ma ọ bụ mmerụ ahụ ọmụmụ ọzọ.
3. Gịnị gụnyere
Your Hessaire M150 Portable Evaporative Cooler package includes the following items:
- Hessaire M150 Evaporative Cooler Unit
- Akwụkwọ ntuziaka onye nwe (akwụkwọ a)
- Casters (4 total: 2 locking, 2 non-locking)
- Brass garden hose adapter

4. Mgbakọ
Hessaire Coolers are pre-assembled and ready to operate with minimal setup. Follow these steps to prepare your unit for use:
- Jiri nlezianya wepụ unit ahụ na nkwakọ ngwaahịa ya.
- Install the four casters into the designated slots at the bottom of the unit. Ensure they are securely fitted.
- Once the unit is in its desired location, lock the two locking wheels to prevent the cooler from moving due to air velocity during operation.

5. Mbido Mbido
Before first use, the pump must be primed according to instructions. Ensure the cooler is positioned correctly for effective operation.
5.1 Water Filling Options
The M150 offers two convenient ways to fill its 10.3-gallon water reservoir:
- Njupụta aka: Open the small panel on the front of the unit to access the fill port. Pour water directly into the reservoir until the water level indicator shows it is full. This provides up to 4 hours of self-contained cooling.

Foto 5.1: Akụkụ view of the cooler, highlighting the water fill panel. - Continuous Fill: For extended operation without manual refilling, use the included brass garden hose adapter. Attach one end to a standard garden hose and the other to the adapter port on the side of the cooler. The unit features a float valve that automatically regulates the water level.

Foto 5.2: Akụkụ view of the cooler, showing the garden hose adapter connection.
5.2 Positioning for Optimal Performance
For the most effective cooling, position your Hessaire M150 in front of an open window or door. It is crucial to also have another open window or door through which the humidified air can exhaust from the room. This creates a cross-ventilation effect, allowing fresh, dry air to enter and humid air to exit, maximizing the evaporative cooling process.
6. Ntuziaka ọrụ
The Hessaire M150 features an easy-to-operate mechanical control panel located on the top of the unit.
6.1 Ogwe njikwa gafereview
The control panel consists of rotary switches for intuitive operation:
- Motor Speed Dial: Turn this dial to power on the cooler and select your desired fan speed: Low, Medium, or High.
- Pump Switch: Turn the pump switch ON to activate the water pump, which saturates the internal Xel50 Cooling Media. For fan-only operation, ensure the pump switch is OFF.
- Air Swing Delivery System (Oscillation) Switch: Turn this switch ON or OFF for automatic oscillation of the internal fan. This feature helps distribute cool air more evenly across a wider area.
The unit can be used in fan-only mode by keeping the pump switch off. This is useful for circulating air without adding humidity.
7. Nlekọta
Mmezi mgbe niile na-eme ka arụmọrụ kachasị mma na ogologo oge nke igwe oyi gị na-ekupụ ikuku.
7.1 Nchacha nzacha
Ensure the cooling media (filter) is kept clean throughout the summer season. A dirty filter can reduce cooling efficiency and airflow.

7.2 Daily Operation Tips
At the end of each day of use, run your cooler on Naanị fan for 30 minutes. This helps to dry out the cooling media, preventing mold and mildew growth and extending its lifespan.
7.3 Nchekwa oyi
Before storing your cooler away for the winter season, perform the following steps:
- Drain the water tank completely and wipe it clean to remove any residue.
- Clean the cooling media thoroughly.
- Reassemble the unit and run it on Naanị fan for 30 minutes to ensure the cooling media is completely dry before storage.
8. Nchọpụta nsogbu
This section addresses common issues you might encounter with your Hessaire M150 Evaporative Cooler.
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Unit anaghị agbanwuo. | Enweghị ike, njikọ na-adịghị mma, gbanyụọ ọkụ eletrik. | Check power cord connection, ensure outlet is functional, turn power switch ON. |
| Enweghị mmetụta jụrụ oyi. | Water tank empty, pump off, cooling media dirty, high humidity. | Fill water tank, turn pump ON, clean cooling media, ensure proper ventilation in low humidity environment. |
| Mbelata ikuku. | Dirty cooling media, blocked air inlets/outlets. | Clean cooling media, ensure no obstructions around the unit. |
| Unusual noise (e.g., clicking, grinding). | Internal component issue, debris in fan. | Unplug unit immediately. Inspect for visible obstructions. If noise persists, contact customer support. |
9. Nkọwapụta
| Njirimara | Nkọwa |
|---|---|
| Ụdị | Hessaire |
| Nọmba nlereanya | M150 |
| Ụdị nkwụnye | Ntighari |
| Atụmatụ pụrụ iche | Oscillating Fan, Portable |
| Ike ikuku | 3100 Cubic Feet kwa nkeji (CFM) |
| Ụdị njikwa | Manual Rotary Dials |
| Ike nchekwa mmiri | 10.3 galọn |
| Mpaghara mkpuchi | Ruo 950 Square Feet |
| Akụkụ ngwaahịa (D x W x H) | 20"D x 10"W x 28"H |
| Ibu Ibu | 40 lbs (Operating Weight: 83 lbs) |
| Voltage | 115 V |
| Oke Wattage | 250 W |
| Kachasị Ampoge | 2.4 Amps |
| Ogologo eriri ike | 72 sentimita asatọ |
| Asambodo nchekwa | ETL |
10. Akwụkwọ ikike na nkwado
For warranty information, technical support, or to purchase replacement parts, please visit the official Hessaire websaịtị ma ọ bụ kpọtụrụ ndị ahịa ha ozugbo.