This manual provides essential instructions for the proper setup, operation, and maintenance of your Sartorius Entris II Compact Precision Scale Lab Balance, model BCE 2202-1S. This high-precision weighing system is designed for laboratory applications, featuring a high-resolution color touchscreen display, RS-232, and USB interfaces, and requiring external calibration for accurate measurements.

Please read this manual thoroughly before using the device to ensure safe and correct operation and to achieve optimal performance.

2. Ntuziaka nchekwa

  • Always operate the balance on a stable, level surface free from vibrations.
  • Ensure the power supply matches the specifications indicated on the device.
  • Avoid exposing the balance to extreme temperatures, direct sunlight, or strong air currents.
  • Do not disassemble the balance; refer servicing to qualified personnel.
  • Keep the weighing pan and surrounding area clean and free from debris.
  • Use only original Sartorius accessories and spare parts.

3. Ngwaahịa gafereview

The Sartorius Entris II BCE 2202-1S is a compact laboratory balance designed for precise measurements. Key components include the weighing pan, a high-resolution color touchscreen display, and intuitive control buttons.

Sartorius Entris II Compact Precision Scale Lab Balance

Foto 1: N'ihu view of the Sartorius Entris II Compact Precision Scale Lab Balance. This image displays the balance with its stainless steel weighing pan, the digital display showing '0.00 g', and control buttons below the display, including power and tare functions. The Sartorius logo is visible on the front panel.

Sartorius Entris II Compact Precision Scale Lab Balance with dimensions

Foto 2: Akụkụ view of the Sartorius Entris II Compact Precision Scale Lab Balance with indicated dimensions. The image shows the balance from an angled perspective, highlighting its compact form factor. Dimensions are marked as approximately 8.66 inches in width, 7.56 inches in depth, and 2.13 inches in height.

4. Nhazi

  1. Iwepu: Carefully remove the balance and all accessories from the packaging. Retain the original packaging for future transport or storage.
  2. Nkwanye: Place the balance on a firm, level, and vibration-free surface. Ensure it is away from direct heat sources, air conditioning vents, and open windows to prevent measurement inaccuracies caused by temperature fluctuations or drafts.
  3. Nkwanye: Use the adjustable feet at the base of the balance to level the device. Adjust until the air bubble in the spirit level (usually located near the display) is centered.
  4. Njikọ ike: Connect the provided power adapter to the balance and then to a suitable power outlet.
  5. Nhazi izizi: This model requires external calibration. Refer to Section 5.4 for detailed calibration procedures before first use to ensure accurate measurements.

5. Ntuziaka ọrụ

5.1 Gbanyụọ ma ọ bụ gbanyụọ

Pịa Ike button (usually marked with a circle and a vertical line) to turn the balance on or off. Allow a brief warm-up period for stable readings after powering on.

5.2 Ibu Ibu Dị Mkpa

  1. Ensure the weighing pan is empty and the display shows '0.00 g'. If not, press the efu bọtịnụ.
  2. Carefully place the item to be weighed onto the center of the weighing pan.
  3. Wait for the reading to stabilize (a stability indicator, often a small circle or arrow, will appear on the display).
  4. Gụọ arọ egosiri na ihuenyo.

5.3 Agụmakwụkwọ

Taring allows you to subtract the weight of a container, so only the net weight of the sample aturu.

  1. Place the empty container onto the weighing pan.
  2. Pịa Tare button (usually marked with a 'T' or '→0←'). The display will reset to '0.00 g'.
  3. Tinye sample to the container. The display will show the net weight of the sample.

5.4 Nhazi Mpụga

External calibration ensures the accuracy of your balance. This procedure requires a certified calibration weight appropriate for the balance's capacity (e.g., 2000g for a 2220g balance).

  1. Ensure the balance is leveled and has been warmed up for at least 30 minutes.
  2. Access the calibration menu via the touchscreen display. (Consult the on-screen prompts or the full Sartorius user manual for specific menu navigation).
  3. Follow the on-screen instructions to initiate the external calibration process.
  4. When prompted, place the specified calibration weight onto the center of the weighing pan.
  5. Wait for the balance to complete the calibration process.
  6. Remove the calibration weight when instructed. The balance will return to normal weighing mode.

6. Nlekọta

6.1 Nhicha

  • Disconnect the balance from the power supply before cleaning.
  • Clean the weighing pan and housing with a soft, damp ákwà na ihe dị nro.
  • Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the display or housing.
  • Ensure no liquids enter the balance housing.

6.2 nlekọta

  • Handle the balance with care; avoid dropping or subjecting it to shocks.
  • Regularly check the leveling of the balance.
  • Perform periodic external calibrations to maintain accuracy.

7. Nchọpụta nsogbu

  • Ọgụgụ na-adịghị akwụsi ike: Check for drafts, vibrations, or temperature fluctuations. Ensure the balance is level.
  • Display Error Message: Refer to the full Sartorius user manual for specific error codes. Often, a power cycle (turning off and on) can resolve minor issues.
  • Balance Not Powering On: Check the power cable connection and the power outlet. Ensure the power adapter is functioning correctly.
  • Ọgụgụ na-ezighi ezi: Perform an external calibration (refer to Section 5.4). Ensure the weighing pan is clean and correctly seated.

If problems persist, contact Sartorius customer support or an authorized service technician.

8. Nkọwapụta

NjirimaraNkọwapụta
NlereanyaBCE 2202-1S
ỤdịSartorius
Ike kacha2220 g
Readability (Resolution)0.01 g
Ụdị ngosiHigh-resolution color touchscreen
Ụdị nhaziMpụga
Ọnụ ụzọRS-232, USB
Ibu Ibu14 pound
Ụbọchị mbụ dịNọvemba 21, 2016

9. Akwụkwọ ikike na nkwado

For warranty information, technical support, or service inquiries, please refer to the official Sartorius website or contact your authorized Sartorius dealer. Keep your purchase receipt and product serial number readily available when contacting support.

Akwụkwọ ndị emetụtara - BCE 2202-1S

Tupuview Sartorius CP | Gemplus Series eletrọnịkị nha nha - ntuziaka ọrụ
Ntuziaka ọrụ zuru oke maka Sartorius CP | Usoro Gemplus eletrọnịkị micro-, nyocha, na nguzozi ziri ezi, gụnyere CPA, GCA, na ụdị GPA. Na-ekpuchi nrụnye, ọrụ, nhazi, mmemme ngwa, nchọpụta nsogbu, mmezi na nkọwapụta.
Tupuview Sartorius Portable and Gold Series Service Manual: Maintenance and Repair Guide
Comprehensive service manual for Sartorius Portable and Gold series weighing scales (PT...-000V1 and GT...-G00V1). Covers adjustment, calibration, repair procedures, troubleshooting, and data interface information for service technicians.
Tupuview Sartorius Secura, Quintix, Practum Laboratory Balances Akwụkwọ ntuziaka onye ọrụ
Akwụkwọ ntuziaka onye ọrụ zuru oke maka Sartorius Secura, Quintix, na nguzo ụlọ nyocha Practum. Nwụnye nkọwa, ọrụ, ntuziaka nchekwa, ngwa nha dị iche iche, ntọala sistemụ na nkọwa nka maka nha ụlọ nyocha.
Tupuview Onye ndu Sartorius CP Gemplus: Istruzioni kwa Bilance Analitiche e di Precisione
Ntuziaka zuru oke maka otu onye ọ bụla si elettroniche Sartorius CP na Gemplus (modelli CPA, GCA, GPA). Gbanyụọ installazione, egwuregwu, impostazioni, manutenzione na kpọmkwem ihe eji eme ihe.
Tupuview Sartorius Lab Balance Cross-Reference Guide: Find Your Perfect Model
Compare Sartorius lab balance models across Cubis MSE, Secura, Quintix, Practum, and Entris series. Find replacement models and FS catalog numbers for your laboratory weighing needs.
Tupuview Sartorius Secura, Quintix, Practum Laboratory Balances Akwụkwọ ntuziaka onye ọrụ
This user manual provides comprehensive instructions for Sartorius Secura®, Quintix®, and Practum® laboratory balances. It details installation, operation, calibration, maintenance, and various weighing applications, ensuring optimal performance and accuracy for laboratory professionals.