Akicon 1424-ORB

Akicon 1424-ORB Bathroom Exhaust Fan with Light and Nightlight User Manual

Model: 1424-ORB

1. Okwu mmalite

This manual provides detailed instructions for the safe installation, operation, and maintenance of your Akicon 1424-ORB Bathroom Exhaust Fan with Light and Nightlight. Please read all instructions carefully before beginning installation or use. Retain this manual for future reference.

The Akicon 1424-ORB is an ultra-quiet ventilation solution designed to effectively remove moisture and odors from your bathroom. It features a powerful 110 CFM fan, an integrated main light, and a nightlight, all within a durable oil rubbed bronze finish.

2. Ozi nchekwa

WARNING: RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS.

  • Installation must be performed by a qualified electrician in accordance with all applicable local codes and standards, including fire-rated construction codes and standards.
  • Always disconnect power at the service panel before wiring or servicing this unit. Lock out the service panel to prevent accidental power-on.
  • Emebere ngwaọrụ a maka ojiji ikuku nkịtị naanị. Ejila ya iji wụfuo ihe ndị dị ize ndụ ma ọ bụ ihe mgbawa na uzuoku.
  • To prevent motor damage and noisy/unbalanced impellers, keep drywall spray, construction dust, etc., off the power unit.
  • Duct work must be installed with a minimum of 4-inch diameter to ensure proper airflow.
  • Hụ na fan ahụ dị n'ala nke ọma.
  • Do not install this fan in a cooking area.

3. Ihe ngwugwu

Chọpụta na akụrụngwa niile dị tupu ịmalite nrụnye:

  • Ebe obibi ndị fan
  • Grille
  • Ìhè mkpuchi
  • 12-inch Suspension Bracket
  • 14-inch Extension Bracket
  • Ịkwanye kposara
  • Grille and Cover Mounting Hardware
  • LED Bulb (Main Light)
  • Igwe ọkụ abalị

4. Nkọwapụta

ỤdịAkicon
Aha Nlereanya1424-ORB
AgbaỌla etere mmanụ
Ofufe ikuku110 CFM
Sone Rating1.5 Ụmụ nwoke
Nha ime ụlọ akwadoroRuo 99 sq. ft.
Housing Dimensions (L x W x H)9" x 9" x 7-11/16"
Light Cover Diameter15-5/16"
Nha ọwa mmiri4 sentimita asatọ
Isi ìhè3 x 9W GU24 Dimmable LED Bulbs (3000K / 5000K)
Ìhè abalị1 x 4W E12 Bulb
Ihe onwunweMetal, Plastic, Glass Cover
Ụdị motoCopper Ball-Bearing Motor
AsambodoHVI-certified, cUL listed (for over-showers and tubs with GFCI)

5. Ntuziaka nwụnye

Proper installation is crucial for the performance and longevity of your exhaust fan. It is recommended that installation be performed by a qualified professional.

5.1 Ntụle tupu ntinye

  • Nweta: This fan is designed for installation in locations with attic access or during new construction. Replacing an existing fan may require modifications to the ceiling opening.
  • Ogo mmeghe: The housing dimensions are 9 inches by 9 inches by 7-11/16 inches. Ensure your ceiling opening is appropriately sized. If replacing an older fan, you may need to enlarge the opening.
  • Ntugharị: Use 4-inch diameter ducting for optimal performance. Ensure duct runs are as short and straight as possible.
  • Nha ime ụlọ: The fan is suitable for rooms up to 99 square feet. To calculate the minimum CFM needed for your bathroom, multiply the room's width, length, and height (in feet) by 0.13.
Installation Notice with Housing Dimensions
Image 1: Installation notice showing the fan housing dimensions (9" x 9" x 7.7") and emphasizing the importance of checking the opening size for replacement installations.
Product Parameter and Dimensions
Image 2: Detailed product parameters including airflow, sone rating, room size, and physical dimensions of the fan housing and light cover.
Attic and Soffit Installation Diagram
Image 3: Diagram illustrating typical installation scenarios, including attic and soffit access for ventilation.
Atụ maka nwụnye
Image 4: Visual guide on how to measure the existing opening and soffit/attic height for proper fan placement.
CFM Calculation Guide
Image 5: Instructions on how to calculate the minimum CFM required for your bathroom based on its dimensions.

5.2 Mounting the Housing

  1. Position the fan housing between ceiling joists. Use the provided 12-inch or 14-inch suspension/extension brackets to secure the housing to the joists.
  2. Ensure the housing is level and securely fastened to prevent vibration and noise.
  3. Connect the 4-inch ductwork to the fan's exhaust collar. Seal all duct connections with duct tape or clamps to prevent air leakage.

5.3 Waya

The fan, main light, and nightlight can be wired jointly or separately to wall switches, depending on your preference and existing wiring. Consult a qualified electrician if you are unsure about wiring procedures.

  1. Route electrical supply wires to the fan housing's junction box.
  2. Remove the junction box cover and connect the wires according to the wiring diagram provided inside the junction box cover and local electrical codes. Ensure proper grounding.
  3. Secure all wire connections with approved wire connectors.
  4. Dochie mkpuchi igbe nkwụsị.

5.4 Na-emecha nwụnye

  1. Install the provided LED bulb for the main light and the E12 bulb for the nightlight into their respective sockets.
  2. Attach the light cover to the fan housing using the provided hardware.
  3. Secure the grille to the housing.
  4. Restore power at the service panel and test the fan, main light, and nightlight functions.
Fan Components and Features
Foto 6: nso nso views detailing the light cover, fan housing, and the copper ball-bearing motor, highlighting the quality construction and components.

6. Ntuziaka ọrụ

The Akicon 1424-ORB fan operates via standard wall switches. Depending on your wiring configuration, you may have separate switches for the fan, main light, and nightlight, or a single switch controlling multiple functions.

  • Ọrụ Fan: Activate the fan by flipping the designated wall switch. The fan will begin to exhaust air from the room.
  • Isi ọrụ ọkụ: Turn on the main LED light using its dedicated wall switch. The main light provides ample illumination for your bathroom.
  • Nightlight Operation: Activate the nightlight with its separate wall switch. The nightlight offers a soft glow for low-light conditions.
  • Njirimara nwere ike imebi: The main LED bulbs are dimmable. If connected to a compatible dimmer switch (not included), you can adjust the brightness. The color temperature can be set to 3000K (warm light) or 5000K (bright light) as per the bulb's specifications.

7. Nlekọta

Regular cleaning and maintenance will ensure optimal performance and extend the life of your exhaust fan.

7.1 Cleaning the Grille and Light Cover

  1. Kwụpụ ike: Gbanyụọ ike mgbe niile na panel ọrụ tupu ị hichaa.
  2. Wepu akụrụngwa: Carefully remove the light cover and grille from the fan housing.
  3. Ọcha: Wash the grille and light cover with a mild detergent and warm water. Rinse thoroughly and allow them to dry completely before reinstallation.
  4. Tinyegharịa: Reattach the light cover and grille to the fan housing.

7.2 Cleaning the Fan Interior

  1. Kwụpụ ike: Hụ na agbanyụrụ ọkụ eletrik na panel ọrụ.
  2. Access Fan: Remove the grille and light cover.
  3. Akara Fan dị ọcha: Use a soft cloth or brush to gently clean dust and debris from the fan blades and motor housing. Avoid using harsh chemicals or abrasive cleaners.
  4. Gbakọtaghachi: Once clean and dry, reassemble the light cover and grille.
  5. Weghachi ike: Turn power back on at the service panel.

8. Nchọpụta nsogbu

If you experience issues with your Akicon exhaust fan, refer to the following common problems and solutions:

NsogbuIhe nwere ike imeNgwọta
Fan anaghị arụ ọrụNo power supply; Loose wiring; Faulty switch; Motor failure.Check circuit breaker/fuse. Verify all wire connections. Test switch. If motor failure is suspected, contact customer support.
Ìhè anaghị agbanwuoNo power supply; Loose wiring; Burnt-out bulb; Faulty switch.Check circuit breaker/fuse. Verify wire connections. Replace bulb. Test switch.
Oke mkpọtụ ma ọ bụ ịma jijijiLoose mounting; Debris in fan blades; Damaged motor/impeller; Improper ducting.Ensure housing is securely mounted. Clean fan blades. Check ductwork for obstructions or kinks. If noise persists, contact customer support.
Poor ventilation performanceBlocked ductwork; Undersized fan for room; Excessive duct length/bends.Check ductwork for obstructions. Ensure ducting is 4-inch diameter. Review room size vs. fan CFM.

If troubleshooting steps do not resolve the issue, please contact Akicon customer support for assistance.

9. Akwụkwọ ikike na nkwado

The Akicon 1424-ORB Bathroom Exhaust Fan with Light and Nightlight is covered by a Akwụkwọ ikike nke afọ 3 site na ụbọchị ịzụrụ. Akwụkwọ ikike a na-ekpuchi ntụpọ dị na ngwa na arụ ọrụ n'okpuru ojiji nkịtị.

For warranty claims, technical support, or any questions regarding your product, please contact Akicon customer service. Keep your proof of purchase for warranty validation.

For more information or to contact support, please visit the official Akicon websaịtị ma ọ bụ lee ozi kọntaktị enyere na akwụkwọ ịzụrụ ihe gị.

Akwụkwọ ndị emetụtara - 1424-ORB

Tupuview AKICON 110 CFM Bathroom Exhaust Fan with RGB LED, Humidity Sensor, 3CCT & Night Light - Use and Care Guide
Comprehensive use and care guide for the AKICON 110 CFM Bathroom Exhaust Fan, featuring RGB LED mode, humidity sensor, 3CCT, and night light. Includes installation instructions for new and existing construction, troubleshooting, and maintenance.
Tupuview AKICON 110 CFM Bathroom Exhaust Fan Use and Care Guide with RGB LED and Humidity Sensor
Detailed use and care guide for the AKICON 110 CFM Bathroom Exhaust Fan. Covers installation (new and existing construction), specifications, safety information, maintenance, troubleshooting, and remote operation for models AKHR110-RGB2-W, AKHR110-RGB2-B, and AKHR110-RGB2-S.
Tupuview AKICON 110 CFM Bathroom Exhaust Fan with RGB LED, Humidity Sensor, 3CCT, and Night Light - Use and Care Guide
Comprehensive use and care guide for the AKICON 110 CFM Bathroom Exhaust Fan, featuring RGB LED mode, humidity sensor, 3CCT color temperature, and night light. Includes installation instructions, safety information, troubleshooting, and warranty details.
Tupuview AKICON BPT14-80CL Bathroom Ventilation Fan with Light Use and Care Guide
Comprehensive use and care guide for the AKICON BPT14-80CL Bathroom Ventilation Fan with Light, detailing product specifications, installation, maintenance, troubleshooting, and warranty information.
Tupuview AKICON AK1390N2-W/B/S Bathroom Ventilation Fan with Light Use and Care Guide
Comprehensive use and care guide for the AKICON AK1390N2-W/B/S bathroom ventilation fan with LED light. Includes installation instructions, safety information, maintenance, troubleshooting, and warranty details.
Tupuview AK-SW-FLHT Humidity Switch User Guide
User guide for the AKICON AK-SW-FLHT Humidity Switch, detailing specifications, setup, operation modes, and wiring instructions for controlling fans and lights based on humidity levels.