CLIVET Cristal

Clivet Cristal Dual Split Air Conditioner User Manual

Model: Cristal | Brand: CLIVET

1. Ngwaahịa gafereview

The Clivet Cristal Dual Split Air Conditioner system is designed to provide efficient cooling and heating for two separate indoor areas using a single outdoor unit. This model features Inverter technology for energy efficiency and includes Wi-Fi connectivity for smart control. The indoor units are designed with a modern, flat, and linear aesthetic with soft curves, making them suitable for various interior designs.

Key features include a high-density filter to capture fine dust and a cold catalyst filter to retain volatile organic compounds and odors, ensuring cleaner air quality.

Image of Clivet Cristal Dual Split Air Conditioner showing two indoor units and one outdoor unit.

This image displays the complete Clivet Cristal Dual Split Air Conditioner system. It features two sleek, white indoor units, typically mounted on a wall, and a single, compact outdoor condenser unit with a protective grille over its fan. The Clivet logo is visible on all components.

2. Ozi nchekwa

Read all instructions carefully before installation and operation. Failure to follow these instructions may result in property damage, personal injury, or death.

3. Ihe ngwugwu

Your Clivet Cristal Dual Split Air Conditioner package typically includes:

4. Ntọala na nwụnye

Installation of a split air conditioning system requires specialized tools and knowledge. It is strongly recommended that installation be performed by a certified HVAC professional to ensure proper functioning, safety, and compliance with local regulations.

Key Installation Steps (Overview for Professional):

  1. Nhọrọ saịtị: Choose appropriate locations for both indoor and outdoor units, considering air circulation, drainage, and structural support.
  2. Nkeji ime ụlọ na-agbago: Securely mount indoor units on the wall, ensuring they are level.
  3. Ngalaba Nkwanye N'èzí: Install the outdoor unit on a stable, level surface or wall bracket, ensuring adequate clearance for airflow.
  4. Ọkpụkpọ ikuku friji: Connect the refrigerant lines between the indoor and outdoor units. Ensure proper flaring and leak testing.
  5. igbapu: Install condensate drain lines for indoor units, ensuring proper slope for water flow.
  6. Ọkụ eletrik: Connect the power supply and communication wiring according to the wiring diagram provided in the detailed installation manual.
  7. Ịchacha na chaja: Evacuate the refrigerant lines to remove air and moisture, then charge the system with the correct amount of refrigerant if necessary.
  8. Nwale ọsọ: Perform a test run to verify proper operation, check for leaks, and confirm cooling/heating performance.

5. Ntuziaka ọrụ

The Clivet Cristal system can be operated via the included remote control or through a Wi-Fi enabled smart device.

Ọrụ njikwa anya:

Njikọ Wi-Fi:

The Wi-Fi feature allows you to control your air conditioner remotely via a smartphone application. Download the official Clivet app from your device's app store and follow the in-app instructions for pairing your unit. This typically involves connecting the unit to your home Wi-Fi network.

6. Nlekọta

Ndozi mgbe niile na-eme ka arụmọrụ kacha mma ma na-agbatị ndụ nke igwe oyi gị. Wepụ ọkụ eletrik mgbe niile tupu ị rụọ ọrụ ọ bụla.

Mmezi nke Ụlọ:

Nlekọta Otu n'èzí:

7. Nchọpụta nsogbu

Tupu ịkpọtụrụ ọrụ, lelee nsogbu ndị a na-ahụkarị:

NsogbuIhe nwere ike imeNgwọta
Unit anaghị ebidoNo power; Remote control batteries low; Timer set.Check power supply/circuit breaker; Replace batteries; Cancel timer setting.
Ezughi oke jụrụ oyi/ọkụDirty air filters; Obstruction at air inlet/outlet; Doors/windows open; Temperature setting incorrect; Refrigerant leak.Clean air filters; Remove obstructions; Close doors/windows; Adjust temperature; Contact professional service for refrigerant issues.
Mkpọtụ na-adịghị ahụkebeAkụkụ rụrụ arụ; Ihe mgbochi ndị fan; Unit abụghị ọkwa.Check for loose parts; Remove fan obstruction; Ensure unit is level. If noise persists, contact service.
Mwepu mmiri sitere na nkeji ime ụlọClogged drain pipe; Unit not level; Condensate pan overflow.Clear drain pipe; Ensure unit is level; Contact professional service if issue persists.

Ọ bụrụ na nsogbu ahụ dịgidere mgbe ị nwara azịza ndị a, biko kpọtụrụ onye na-ahụ maka ọrụ ruru eru.

8. Nkọwapụta

NjirimaraNkọwa
ỤdịCLIVET
Aha NlereanyaCristal
ỤdịDual Split System
Ike nkeji ime ụlọ2 x 12,000 BTU
Ike nkeji dị n'èzí5.4 kW
Nkà na ụzụIhe ntụgharị
Ogo arụmọrụ ike ikeA++ (as per product title) / SEER 5 (from specs)
Voltage220 volts
Atụmatụ pụrụ icheWi-Fi Connectivity, Inverter Compressor, High-Density Filter, Dust Filter
Recommended Room Size (per indoor unit)25 to 40 m² (approx. 2.7m height)

9. Akwụkwọ ikike na nkwado

Warranty terms and conditions are typically provided with your purchase documentation. Please refer to the warranty card or contact your retailer for specific details regarding coverage period and service procedures.

For technical support, spare parts, or professional service, please contact your authorized Clivet dealer or the customer service number provided in your purchase documentation. Always provide your model number (Cristal) and serial number when seeking support.