1. Okwu mmalite
This manual provides comprehensive instructions for the installation, operation, and maintenance of your Intermatic ET2815C Astro 365/7-Day Electronic Timer. Please read this manual thoroughly before installation and use to ensure proper function and safety. This electronic timer is designed for precise control of electrical loads, offering advanced scheduling capabilities for various applications.
2. Ozi nchekwa
ỊDỌ AKA NA NTỊ: Ihe ize ndụ nke ọkụ ma ọ bụ ọkụ eletrik
- Disconnect power at the circuit breaker(s) or disconnect switch(es) before installing or servicing this device.
- Enwere ike ịchọ ihe karịrị otu mgbanaka sekit ma ọ bụ mgba ọkụ kwụpụ iji mebie akụrụngwa tupu ịrụ ọrụ.
- Nwụnye na/ma ọ bụ wiring ga-adịrịrị n'usoro koodu eletrik nke mba na mpaghara chọrọ.
- Jiri naanị ndị nduzi kọpa.
- Do NOT remove the insulator covering the terminals.
Ntuziaka waya: To wire, lift the terminal cover, remove the screw, and swing it aside. Replace the screw and the plastic insulator covering the terminal before powering on the device.

Foto a na-egosi ihu view of the Intermatic ET2815C electronic timer. Visible elements include the digital display, control buttons such as MODE, DAY, ENTER/NEXT, ON/OFF, CLEAR MEM, and the CLEAR ENTRY buttons with plus and minus symbols. Below the main controls, safety warnings in English, French, and Spanish regarding electrical shock and fire hazards are printed, along with instructions for wiring and not removing the insulator. The model name 'Astro 365/7-Day' is prominently displayed at the top.
3. Ngwaahịa gafereview
The Intermatic ET2815C is an advanced electronic timer designed for precise control over electrical circuits. It features a user-friendly interface and robust capabilities suitable for a wide range of applications.
Akụkụ ndị bụ isi:
- Astro 365/7-Day Operation: Provides flexible scheduling options for every day of the week, year-round.
- 96 Set Points/Events: Allows for up to 96 distinct ON/OFF programming events.
- 50 Holiday Blocks: Independent scheduling for up to 50 holiday periods.
- 100-Hour Supercapacitor: Eliminates the need for batteries by providing backup power for settings during outages.
- 2-Hour Override Mode: An additional mode of operation that turns the ON/OFF buttons into a 2-hour override function.
- Voltage: Operates on 120 to 277Vac.
- Ampafọ: Enyere ya maka 20 Amps.
bọtịnụ njikwa:
Refer to the product image in Section 2 for the location of these buttons:
- Edị: Cycles through different programming modes.
- Ụbọchị: Used to set the day of the week or select specific days for programming.
- ENTER/NEXT: Confirms selections and moves to the next programming step.
- Gbanyụọ/gbanyụọ: Manually controls the load or activates override mode.
- CLEAR MEM: Clears all programmed events.
- CLEAR ENTRY: Clears the current entry during programming.
- +/- bọtịnụ: Adjust values (time, day, program number).
4. Nwụnye
Mkpa: Before proceeding with installation, ensure all safety warnings in Section 2 are understood and followed. Disconnect all power to the circuit at the breaker or disconnect switch before beginning any wiring.
Ịkwanye:
- Select a suitable location for mounting the timer, ensuring it is protected from moisture and extreme temperatures.
- Mount the timer securely using appropriate fasteners.
Wiring:
All wiring must comply with national and local electrical codes. Use COPPER conductors ONLY.
- Access the wiring terminals by lifting the terminal cover, removing the screw, and swinging it aside as indicated on the device.
- Connect the incoming power supply wires (Line) and the load wires (to the device being controlled) to the appropriate terminals.
- Gbaa mbọ hụ na njikọ niile siri ike na nchekwa.
- Replace the screw and the plastic insulator covering the terminals before restoring power.
- Restore power to the circuit at the breaker or disconnect switch.
5. Nhazi
Initial Power-Up and Time Setting:
- Upon initial power-up, the display may show a default time or be blank.
- Pịa MODE button until the time setting mode is displayed.
- Jiri ihe + na - bọtịnụ iji hazie awa na nkeji.
- Pịa BAnye/Osote iji kwado oge.
- Jiri ihe ỤBỌCHỊ bọtịnụ na + / - buttons to set the current day of the week.
- Pịa BAnye/Osote to confirm the day.
- The timer is now set to the current time and day.
6. Ntuziaka ọrụ
Programming ON/OFF Events:
The ET2815C allows for up to 96 ON/OFF events.
- Pịa MODE button until 'PROG' or 'PROGRAM' appears on the display.
- The display will show 'P1 ON' (Program 1 ON). Use + / - to set the desired ON time.
- Pịa BAnye/Osote.
- Jiri ihe ỤBỌCHỊ button to select the days of the week for this ON event (e.g., Mon-Fri, Daily, or specific days).
- Pịa BAnye/Osote.
- The display will show 'P1 OFF'. Use + / - to set the desired OFF time.
- Pịa BAnye/Osote.
- Jiri ihe ỤBỌCHỊ button to select the days of the week for this OFF event.
- Pịa BAnye/Osote to save Program 1 and move to 'P2 ON'.
- Repeat steps for additional programs. To exit programming, press MODE ruo mgbe egosipụtara oge dị ugbu a.
Holiday Block Programming:
The timer supports up to 50 holiday blocks with independent scheduling.
- Consult the full product manual for detailed steps on setting holiday blocks, as this feature involves specific date ranges.
Manual Override and 2-Hour Override Mode:
- Gbanyụọ/ Gbanyụọ akwụkwọ ntuziaka: Pịa Gbanye/ Gbanyụọ button to manually switch the load ON or OFF, overriding the current program until the next scheduled event.
- 2-Hour Override: In a specific operating mode (refer to the full manual for activation), pressing the Gbanye/ Gbanyụọ button will activate a 2-hour override, after which the timer will revert to its programmed schedule.
Clearing Programs:
- CLEAR ENTRY: During programming, press CLEAR ENTRY to clear the current value or selection.
- CLEAR MEM: To clear all programmed events, press and hold the CLEAR MEM button for a few seconds until the display confirms the memory has been cleared.
7. Nlekọta
The Intermatic ET2815C timer is designed for minimal maintenance.
- Nhicha: Jiri ákwà dị nro ma kpọọ nkụ hichaa mpụta ihe n'ime oge ahụ mgbe ụfọdụ. Ejila ihe nhicha ma ọ bụ ihe mgbaze.
- Ndabere batrị: The timer utilizes a 100-hour supercapacitor for backup power, eliminating the need for battery replacement. This supercapacitor recharges automatically when power is supplied to the unit.
8. Nchọpụta nsogbu
If you encounter issues with your Intermatic ET2815C timer, consider the following common troubleshooting steps:
- Timer Display is Blank: Check the power supply to the timer. Ensure the circuit breaker is ON and wiring connections are secure.
- Load Not Turning ON/OFF as Programmed:
- Verify that the current time and day are set correctly.
- Review your programmed ON/OFF events for accuracy, including the selected days of the week.
- Check if a manual override is active.
- Ensure the load itself is functioning correctly.
- Difficulty Programming: Refer back to Section 6 and follow the programming steps carefully. Use the CLEAR ENTRY button to correct mistakes during input.
- Ngụ oge anaghị aza: Disconnect power to the timer for a few minutes at the circuit breaker, then restore power. This may reset the unit.
If problems persist after attempting these steps, contact Intermatic customer support for further assistance.
9. Nkọwapụta
| Nọmba nlereanya | ET2815C |
| Ụdị | Intermatic |
| Voltage | 120-277Vac |
| Ampoge | 20 Amps |
| Ụdị ọrụ | Astro 365/7-Day |
| Number of Set Points | Up to 96 ON/OFF events |
| Holiday Blocks | Ruo 50 |
| Ike ndabere | 100-Hour Supercapacitor |
| Ihe onwunwe | Plastic |
| Akụkụ ngwaahịa | 7 x 7 x 7 sentimita asatọ |
| Ibu Ibu | 1.32 pound (gram 600) |
| UPC | 078275148239 |
10. Akwụkwọ ikike na nkwado
This Intermatic product is covered by a manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation included with your purchase or visit the official Intermatic websaịtị.
Maka nkwado teknụzụ, ajụjụ ngwaahịa, ma ọ bụ ịchọta ebe ọrụ enyere ikike, biko gaa na Intermatic websaịtị or contact their customer service department directly.