The AUTOOL LM120+ Digital Manifold Gauge is a professional instrument designed for comprehensive testing and maintenance of HVAC and refrigeration systems. It provides accurate digital readings for pressure, temperature, and vacuum, facilitating efficient diagnosis and servicing of air conditioners and refrigerators. This kit includes the main gauge unit, temperature probes, and connecting hoses, offering a complete solution for refrigerant management.

AUTOOL LM120+ Digital Manifold Gauge kit with hoses and temperature clips

Figure 1: AUTOOL LM120+ Digital Manifold Gauge and included accessories.

2. Ozi nchekwa

Please read and understand all safety warnings and instructions before operating the AUTOOL LM120+ Digital Manifold Gauge. Failure to follow these instructions may result in equipment damage, personal injury, or property damage.

3. Ihe ngwugwu

Mgbe ịmepechara ngwugwu ahụ, biko chọpụta na ihe niile edepụtara n'okpuru dị ugbu a yana ọ dị mma:

4. Akụrụngwa Ngwaahịa

The AUTOOL LM120+ offers a range of advanced features for precise HVAC system analysis:

5. Nhazi na Njikwa Ngwaọrụ

Familiarize yourself with the components and controls of the LM120+ Digital Manifold Gauge:

Diagram of AUTOOL LM120+ Digital Manifold Gauge with numbered parts and their descriptions.

Figure 8: LM120+ Digital Manifold Gauge Components.

Tebụl 1: Nkọwa nke Akụkụ
Mba.AkụkụNkọwa
1nkoFor hanging the unit during operation.
2Clamp-on Temperature Probe SocketConnection point for temperature clamp nyocha.
3Ngosipụta LCDShows pressure, temperature, and other readings.
4Bọtịnụ ọrụUsed to cycle through different functions.
5Bọtịnụ Gbaa/KwụsịStarts or stops measurement processes.
6Bọtịnụ ZeroResets pressure readings to zero.
7R+/R- Refrigerant Type Selection ButtonsUsed to select the type of refrigerant.
8Bọtịnụ na-emepe emepeNa-edozi nchapụta ngosi.
9Otu bọtịnụChanges measurement units (e.g., kPa, psi, bar).
10Celsius C / ° F ButtonToggles temperature display between Celsius and Fahrenheit.
11bọtịnụ ikeGbanyụọ ma ọ bụ gbanyụọ ngwaọrụ.
12Refrigerant Observation WindowAllows visual inspection of refrigerant flow.
13Valve nrụgide dị alaControls flow to the low-pressure side.
14Valve nrụgide dị eluControls flow to the high-pressure side.
151/4 inch Low Pressure InletConnection port for low-pressure hose.
16Valve enyemakaNa-ewepụta oke nrụgide.
171/4 inch High Pressure InletConnection port for high-pressure hose.
18Refrigerant Inlet / Vacuum Pump InletCentral connection for refrigerant charging or vacuum pump.

6. Nhazi

  1. Nwụnye batrị: Open the battery compartment on the back of the unit and insert the required batteries (typically AA or AAA, refer to device markings if present). Ensure correct polarity.
  2. Ike Na: Pịa bọtịnụ ike (11) to turn on the device. The LCD display (3) should illuminate.
  3. Nhọrọ nkeji: Pịa Otu bọtịnụ (9) to cycle through available pressure units (e.g., kPa, psi, bar) and the Celsius C / ° F Button (10) for temperature units. Select your preferred units.
  4. Nhazi efu: Before connecting to a system, ensure all valves (13, 14) are closed and the hoses are disconnected. Press the Bọtịnụ Zero (6) to calibrate the pressure sensors to zero. This ensures accurate readings.
  5. Connect Temperature Probes: Plug the temperature clamp probes into the Clamp-on Temperature Probe Sockets (2) on the top of the unit. Attach the clamps securely to the high and low-pressure lines of the HVAC system.
    AUTOOL LM120+ connected with hoses and temperature clamps.

    Figure 9: Connecting temperature probes and hoses.

  6. Jikọọ Hoses:
    • Connect the blue hose to the Low Pressure Inlet (15) on the gauge and to the low-pressure service port of the HVAC system.
    • Connect the red hose to the High Pressure Inlet (17) on the gauge and to the high-pressure service port of the HVAC system.
    • Connect the yellow (or central) hose to the Refrigerant Inlet / Vacuum Pump Inlet (18) on the gauge. This hose will be used for vacuuming, charging, or connecting to a recovery unit.
    Close-up of the manifold gauge's brass valve connections.

    Ọgụgụ 10: Zuru ezu view of hose connection points.

7. Ntuziaka ọrụ

This section outlines common operational procedures for the LM120+.

7.1. Selecting Refrigerant Type

  1. With the device powered on, press the R+/R- Buttons (7) to scroll through the available refrigerant types (e.g., R134a, R22, R410a).
  2. Select the refrigerant type that matches the system you are working on. This is crucial for accurate pressure-temperature conversions.

7.2. Performing Pressure and Temperature Tests

  1. Ensure hoses and temperature probes are correctly connected to the system.
  2. Slowly open the high-pressure (red) and low-pressure (blue) valves on the manifold to allow refrigerant to flow into the gauge.
  3. The LCD display will show real-time pressure readings for both high and low sides, along with corresponding saturation temperatures based on the selected refrigerant.
  4. The temperature probes will display the actual line temperatures (T1 and T2).
  5. Compare the saturation temperatures with the actual line temperatures to determine superheat and subcooling, which are critical for system diagnosis.

7.3. Performing a Pressure Leakage Test

  1. Connect the gauge to the system and pressurize it to the desired test pressure (ensure system can handle the pressure).
  2. Mechie valvụ niile.
  3. Pịa Bọtịnụ ọrụ (4) to navigate to the leakage test mode.
  4. Pịa Bọtịnụ Gbaa/Kwụsị (5) to start the leakage test timer. The gauge will record the initial pressure.
  5. Allow the test to run for a specified period (e.g., 15-30 minutes, or as per system manufacturer's recommendations).
  6. The display will show the elapsed time and the pressure difference. A significant drop in pressure indicates a leak.
  7. Pịa Bọtịnụ Gbaa/Kwụsị (5) again to stop the test.

7.4. Refrigerant Charging/Evacuation

The LM120+ can be used in conjunction with a vacuum pump and refrigerant tank for system evacuation and charging. Always refer to the specific HVAC system's service manual for proper procedures and refrigerant amounts.

  1. Mwepu: Connect the yellow hose to a vacuum pump. Open the manifold valves and the vacuum pump valve to evacuate the system to the desired vacuum level. Monitor the vacuum reading on the gauge.
  2. Ịchaji: After evacuation, close the manifold valves and disconnect the vacuum pump. Connect the yellow hose to a refrigerant tank. Purge the yellow hose of air. Slowly open the appropriate manifold valve (low side for vapor charge, high side for liquid charge with caution) to allow refrigerant into the system. Monitor pressure and temperature readings.

8. Nlekọta

9. Nchọpụta nsogbu

Tebụl 2: Okwu nkịtị na Ngwọta
NsogbuIhe nwere ike imeNgwọta
Ngwaọrụ anaghị agbanwu ọkụ.Batrị dị ala ma ọ bụ nwụrụ anwụ; echichi batrị ezighi ezi.Dochie batrị ọhụrụ, na-ahụ na polarity ziri ezi.
Ọgụgụ nrụgide na-ezighi ezi.Gauge not zeroed; incorrect refrigerant selected; sensor malfunction; hose leaks.Perform zero calibration; verify refrigerant type; check hose connections for leaks; contact support if issue persists.
Temperature readings are incorrect or absent.Temperature probes not connected properly; damaged probes.Ensure probes are fully inserted into sockets; check probe cables for damage; replace probes if faulty.
Ngosipụta adịchaghị ma ọ bụ na-egbuke egbuke.Low batteries; display settings.Replace batteries; use the Dimming Button (8) to adjust brightness.
Cannot select refrigerant type.Buttons not responding; device malfunction.Ensure buttons are pressed firmly; restart the device; contact support.

10. Nkọwapụta

Tebụl 3: Nkọwa nka nka
OkeUru
ỤdịỤgbọala
Nọmba nlereanyaLM 120
Akụkụ ngwaahịa (L x W x H)Ihe dị ka 210mm x 120mm x 65mm (8.27in x 4.72in x 2.56in)
Ibu Ibu950 grams
Nha ihuenyo12 Inches (display area, not physical device size)
Ndakọrịta refrigerantMultiple common refrigerants (e.g., R134a, R22, R410a, etc.)
Ngalaba nrụgidekPa, psi, bar (selectable)
Nkeji okpomọkụ°C, °F (selectable)

11. Akwụkwọ ikike na nkwado

For warranty information, technical support, or service inquiries regarding your AUTOOL LM120+ Digital Manifold Gauge, please contact AUTOOL customer service directly. Refer to the product packaging or the official AUTOOL websaịtị maka nkọwa kọntaktị kachasị ugbu a.

Please have your product model number (LM 120) and purchase information ready when contacting support.

Akwụkwọ ndị emetụtara - LM 120

Tupuview AUTOOL LM120/LM120+ Digital Manifold Gauge User Manual
This user manual provides comprehensive guidance for the AUTOOL LM120/LM120+ Digital Manifold Gauge. It details product specifications, structure, function instructions for refrigerant filling, vacuum operation, and pressure leak testing. The manual also includes common problems, a glossary of terms, maintenance advice, warranty information, and return/exchange procedures. Essential for HVAC technicians and refrigeration professionals.
Tupuview Akwụkwọ ntuziaka AUTOOL LM120+ Digital Manifold Gauge
Comprehensive user manual for the AUTOOL LM120+ Digital Manifold Gauge, detailing its features, specifications, safety precautions, operating instructions, and troubleshooting tips for refrigeration and HVAC systems.
Tupuview AUTOOL LM150 Digital Manifold Pressure Tester User Manual - HVAC Refrigerant Tool
Comprehensive user manual for the AUTOOL LM150 Digital Manifold Pressure Tester. Covers product specifications, operating instructions for refrigerant filling, vacuum, and leak testing, common problems, glossary of terms, maintenance, warranty, and return policy for HVAC and refrigeration professionals.
Tupuview AUTOOL Im 120 Digital Manifold Gauge User Manual
Comprehensive user manual for the AUTOOL Im 120 Digital Manifold Gauge, detailing its features, specifications, operation instructions for refrigerant filling, vacuum testing, leak detection, safety precautions, common problems, and a glossary of terms relevant to refrigeration systems.
Tupuview AUTOOL LM120/LM120+ Digital Manifold Gauge User Manual
User manual for the AUTOOL LM120/LM120+ Digital Manifold Gauge, detailing its features, safety guidelines, specifications, and operational procedures for HVAC system installation, testing, and maintenance.
Tupuview Akwụkwọ ntuziaka AUTOOL LM160 Smart Digital Manifold Kit
Comprehensive user manual for the AUTOOL LM160 Smart Digital Manifold Kit, covering operation, technical specifications, maintenance, and safety for HVAC applications.