Elitech LogEt 8 THE

Elitech LogEt 8 Ntuziaka Ntuziaka maka Ndekọ Okpomọkụ Dijitalụ na Iru Mmiri

Model: LogEt 8 THE

1. Ngwaahịa gafereview

The Elitech LogEt 8 THE is a reusable digital data logger designed for monitoring temperature and humidity. It is suitable for various applications, including cold chain management for pharmaceuticals, vaccines, food, and other sensitive products. This device features high precision sensors, multiple alarm thresholds, and direct USB connectivity for data download and report generation.

Elitech LogEt 8 THE Digital Temperature and Humidity Data Logger with external probe

Image: Elitech LogEt 8 THE Digital Temperature and Humidity Data Logger with its external probe. The device displays "32.9" and has "START" and "STOP" buttons.

2. Atụmatụ igodo

  • High-precision Temperature & Humidity Sensor: Wide temperature range from -40°F to 185°F with ±0.5°F accuracy. Humidity measuring range: 10%RH to 90%RH, with ±3%RH accuracy.
  • Otutu Mkpu: Configurable with up to 5 alarm thresholds (3 high, 2 low).
  • Plug and Read Functionality: Direct USB connection for data download without requiring a separate cable or reader.
  • Automatic PDF Report Generation: Encrypted PDF reports are automatically generated with password protection. Free Elitechlog software provides personalized settings and management.
  • Ogologo oge ndụ: Utilizes a replaceable lithium battery for extended operation.

3. Ngwa ngwaọrụ

Diagram of Elitech LogEt 8 THE components

Image: Diagram illustrating the components of the Elitech LogEt 8 THE data logger. Key components include: 1. USB Port, 2. LCD Screen, 3. Buttons (START/STOP), 4. External Temperature and Humidity Sensor, and 5. Battery Cover.

  1. Ọdụ ụgbọ mmiri USB: Used for connecting to a computer for data download and configuration.
  2. Ihuenyo LCD: Displays current temperature, humidity, and device status.
  3. Bọtịnụ: "START" button to initiate logging, "STOP" button to cease logging.
  4. Okpomọkụ mpụga na ihe mmetụta iru mmiri: Provides accurate environmental readings.
  5. Mkpuchi batrị: Protects the replaceable lithium battery compartment.

4. Nhazi

4.1 Nyocha mbụ

Upon receiving your LogEt 8 THE data logger, inspect the packaging and device for any signs of damage. Ensure all included components (data logger, calibration certificate, user manual) are present.

4.2 Nwụnye ngwanrọ

Before first use, download and install the Elitechlog software from the official Elitech website. This software is required for device configuration, data download, and report generation.

  • Visit the Elitech official websaịtị.
  • Navigate to the support or download section.
  • Download the Elitechlog software compatible with your operating system (Windows/macOS).
  • Soro ntuziaka ihuenyo iji mezue nrụnye.
Elitech LogEt 8 THE connected to a laptop for data export

Image: The Elitech LogEt 8 THE data logger plugged into a laptop's USB port, illustrating the data export process via ElitechLogWin software to PDF, Excel, or TXT formats.

4.3 Nhazi ngwaọrụ

Connect the data logger to your computer via the USB port. The Elitechlog software will detect the device. Use the software to configure parameters such as:

  • Ogologo oge nbanye
  • Malite igbu oge
  • Alarm thresholds (high/low temperature and humidity)
  • Nkeji okpomọkụ (°C/°F)
  • Mpaghara oge

Ensure the external temperature and humidity sensor is securely connected to the device before deployment.

5. Ọrụ

5.1 Mmalite Ndekọ Data

Pịa ma jide Malite button for approximately 3 seconds until the "REC" indicator appears on the LCD screen. This indicates that the device has begun recording data according to the configured settings.

5.2 Stopping Data Logging

Ka ịkwụsị ịkụ osisi, pịa ma jide KWỤSỊ button for approximately 3 seconds. The "REC" indicator will disappear from the LCD screen, confirming that logging has ceased.

5.3 Reading Data and Generating Reports

After logging is complete, connect the data logger to a computer via the USB port. The Elitechlog software will automatically recognize the device and prompt you to download the recorded data. The software will then generate an encrypted PDF report, which can also be exported to Excel or TXT formats for further analysis.

Elitech LogEt 8 THE generating a PDF report

Image: A visual representation of the Elitech LogEt 8 THE data logger connected to a computer, showing the generation of a PDF report. The report includes a graph of temperature and humidity data over time.

5.4 Nchekwa okwuntughe

The generated PDF reports can be password-protected for enhanced data security. This feature is configured within the Elitechlog software.

6. Nlekọta

6.1 nnọchi batrị

The LogEt 8 THE uses a replaceable lithium battery. When the battery indicator on the LCD screen shows low power, replace the battery to ensure continuous and accurate operation. To replace the battery:

  1. Locate the battery cover (Component 5 in the diagram).
  2. Jiri nlezianya mepee mkpuchi batrị.
  3. Remove the old battery and insert a new compatible lithium battery, observing polarity.
  4. Mechie mkpuchi batrị nke ọma.

6.2 Nhicha

Wipe the device clean with a soft, dry cloth. Avoid using abrasive cleaners or solvents that could damage the casing or screen. Ensure the device is dry before use.

6.3 Nchekwa

When not in use for extended periods, store the data logger in a cool, dry place away from direct sunlight and extreme temperatures. Remove the battery if storing for very long durations to prevent leakage.

7. Nchọpụta nsogbu

NsogbuIhe nwere ike imeNgwọta
Ngwaọrụ anaghị agbanwu ọkụ.Batrị dị ala ma ọ bụ mebie.Dochie batrị.
Data not logging.Logging not initiated or stopped prematurely.Gbaa mbọ hụ na Malite button was pressed and held until "REC" appears. Check battery level.
Cannot connect to computer/software.USB connection issue; software not installed or outdated.Ensure the device is fully inserted into the USB port. Verify Elitechlog software installation and update to the latest version. Try a different USB port.
Ọgụgụ na-ezighi ezi.Sensor obstruction or damage; device placed in extreme conditions.Ensure the external sensor is clean and unobstructed. Relocate the device to a suitable environment within its operating range.
PDF report not generated.Software error; insufficient disk space.Restart the Elitechlog software and try again. Ensure sufficient storage space on your computer.

8. Nkọwapụta

NjirimaraNkọwa
Nọmba nlereanyaLogEt 8 THE
Oke okpomọkụ-40°F ruo 185°F (-40°C ruo 85°C)
Okpomọkụ ziri ezi±0.5°F (±0.3°C)
Oke iru mmiri10% RH na 90% RH
Ikike iru mmiri± 3% RH
Ike ndekọ16000 isi
NjikọtaUSB
Ụdị akụkọPDF (automatic, encrypted), Excel, TXT
Isi Iyi Ike1 Lithium Metal battery (included, replaceable)
Akụkụ ngwaahịa4 x 1.8 x 0.8 sentimita asatọ
Ibu3.17 ounces
Ngwa gụnyereData Logger, Calibration Certificate, User Manual
Elitech LogEt 8 THE temperature and humidity range

Image: The Elitech LogEt 8 THE data logger displaying its temperature range from -40°C/-40°F to 85°C/185°F and indicating a 16000 points record capacity.

9. Akwụkwọ ikike na nkwado

Elitech provides US Technician Support via Email and Phone for any inquiries or issues you may encounter with your LogEt 8 THE data logger. Please refer to the official Elitech website or the included documentation for specific warranty terms and contact information.

For technical assistance, please visit the Elitech official websaịtị or contact their support team directly.

Akwụkwọ ndị emetụtara - LogEt 8 THE

Tupuview Nkọwapụta na Akwụkwọ ntuziaka onye ọrụ nke Elitech LogEt 5 Series
Nkọwapụta zuru oke, atụmatụ, na ntuziaka ọrụ maka usoro Elitech LogEt 5 nke ndị na-edekọ data okpomọkụ na iru mmiri, nke e mere maka nlekota oyi.
Tupuview Ntuziaka Onye Ọrụ Ndekọ Data PDF nke Elitech LogEt 1 Series Otu-Ojiji
Akwụkwọ ntuziaka onye ọrụ maka ndị na-edekọ data PDF nke Elitech LogEt 1, LogEt 1TH, na LogEt 1Bio nke otu oge, na-ekpuchi ọdịdị, nkọwapụta teknụzụ, ntuziaka ihe ngosi, na ọrụ.
Tupuview Ntuziaka Onye Ọrụ nke Ndekọ Data Elitech LogEt 8 Series - Nlekota Okpomọkụ na Iru Mmiri
Akwụkwọ ntuziaka zuru oke maka ndị na-edekọ data Elitech LogEt 8 Series, nkọwapụta zuru ezu, ọrụ, ntinye, na nsogbu nchọpụta maka nlekota okpomọkụ na iru mmiri na nhazi usoro oyi.
Tupuview Elitech LogEt 260 Series Instruction Manual - Temperature, Light, Vibration Data Loggers
Comprehensive instruction manual for the Elitech LogEt 260 series data loggers, covering safety, product features, selection, technical parameters, operation, and LED indicators. Features temperature, light, vibration monitoring, and 4G connectivity.
Tupuview Akwụkwọ ntuziaka onye ọrụ Elitech LogEt 5 Series: Ndị na-edekọ data okpomọkụ na iru mmiri
Akwụkwọ ntuziaka zuru oke maka ndị na-edekọ data okpomọkụ na iru mmiri nke Elitech LogEt 5 Series.view, nhọrọ nlereanya, nkọwapụta, ọrụ, ihe ngosi ọnọdụ, nnọchi batrị, na nhazi ndabara.
Tupuview Akwụkwọ ntuziaka onye ọrụ Elitech LogEt 1 Series: Ndị na-edekọ data okpomọkụ na iru mmiri
Akwụkwọ ntuziaka zuru oke maka usoro Elitech LogEt 1 nke ndị na-edekọ data otu oge, nke gụnyere LogEt 1 (okpomọkụ), LogEt 1TH (okpomọkụ-iru mmiri), na LogEt 1 Bio (okpomọkụ ziri ezi dị elu). Gụnyere nkọwapụta, ọrụ, ihe ngosi ọnọdụ, na ịdọ aka ná ntị.