FORA IR42

FORA IR42 Non-Contact Forehead Thermometer Instruction Manual

Model: IR42 | Brand: FORA

1. Okwu mmalite

The FORA IR42 Non-Contact Forehead Thermometer is a medical-grade device designed for quick, accurate, and hygienic temperature measurement. Utilizing infrared technology, it provides readings in just one second without physical contact, making it ideal for infants, children, and adults. This manual provides comprehensive instructions for safe and effective use of your thermometer.

FORA IR42 Non-Contact Forehead Thermometer showing 98.6 degrees Fahrenheit

Figure 1: The FORA IR42 Non-Contact Forehead Thermometer.

Akụkụ ndị bụ isi:

2. Nhazi

2.1. Unboxing na akụrụngwa

Mgbe ị meghere ngwugwu ahụ, hụ na ihe niile dị na ya dị:

FORA IR42 Forehead Thermometer in its retail packaging

Figure 2: Product packaging showing the thermometer and its features.

2.2. Ntinye batrị

  1. Locate the battery compartment cover on the back of the thermometer.
  2. Mia mkpuchi ala ka imeghe akụkụ ahụ.
  3. Tinye batrị AAA abụọ, hụ na polarity ziri ezi (+ na -) dịka egosiri n'ime ngalaba ahụ.
  4. Weghachite mkpuchi nke batrị batrị n'ime ebe ruo mgbe ọ pịrị na nchekwa.

Note: The thermometer requires 2 x 1.5V AAA alkaline batteries.

3. Ntuziaka ọrụ

3.1. Taking a Forehead Temperature Measurement

  1. Ensure the thermometer is in the correct mode (Adult or Child, see section 3.2).
  2. Hold the thermometer approximately 1 to 2.5 inches (3-7 cm) away from the center of the forehead.
  3. Pịa bọtịnụ ike () otu ugboro.
  4. The temperature reading will appear on the LCD display within one second.
  5. A green backlight indicates a normal temperature. A red backlight indicates an elevated temperature (fever).
Person using FORA IR42 thermometer to take a non-contact forehead temperature reading on a baby

Figure 3: Demonstrating hygienic non-contact temperature measurement.

3.2. Switching Between Adult and Child Modes

The FORA IR42 offers specific modes for adult and child temperature measurement, which may have different fever thresholds.

  1. With the thermometer powered on, locate the "MODE" button on the side of the device.
  2. Press the "MODE" button to toggle between Adult and Child modes. The display will show an icon indicating the selected mode (e.g., an adult figure or a child figure).
Diagram showing adult and child temperature modes with different fever thresholds

Figure 4: Visual representation of Adult and Child Temperature Modes.

3.3. Measuring Surface/Object Temperature

This thermometer can also measure the temperature of surfaces or objects, such as baby formula, bath water, or room temperature.

  1. Ensure the thermometer is in Surface mode (indicated by a thermometer icon). If not, press the "MODE" button until the surface icon appears.
  2. Point the thermometer at the desired surface or object from a distance of 1 to 2.5 inches (3-7 cm).
  3. Pịa bọtịnụ ike () otu ugboro.
  4. The surface temperature will be displayed.
Illustrates using the thermometer to measure temperatures of baby bottle, room, and bath water

Ọgụgụ 5: Ọpụamples of convenient object/surface temperature measurement.

3.4. Ịgbanwe n'etiti Celsius na Fahrenheit

The thermometer allows you to switch between Celsius (℃) and Fahrenheit (℉) temperature units.

  1. With the thermometer powered off, press and hold the "MODE" button for 2 seconds to enter the selection mode.
  2. Press the "MODE" button again to toggle between ℃ and ℉.
  3. Pịa bọtịnụ ike () to confirm your selection and exit the setting mode.

Video 1: Demonstrates how to switch temperature readings between Celsius and Fahrenheit on the FORA IR42 thermometer.

3.5. Ọrụ ebe nchekwa

The thermometer automatically stores the last 30 temperature measurements. To view agụmagụ gara aga:

  1. With the thermometer powered on, press the "MEMORY" button (usually located on the side, near the MODE button).
  2. Each press of the "MEMORY" button will cycle through the stored readings, from most recent to oldest.
Thermometer display showing a high temperature reading in red and a normal reading in green, illustrating data storage and fever indication

Figure 6: Display showing fever indication and memory storage capability.

4. Nlekọta

4.1. Nhicha

Iji hụ na a na-agụ ihe nke ọma ma na-edebe ya ọcha, hichaa temometa ahụ mgbe niile:

4.2. Nchekwa

Store the thermometer in a cool, dry place, away from direct sunlight, extreme temperatures, and humidity. Remove batteries if the device will not be used for an extended period to prevent leakage.

5. Nchọpụta nsogbu

NsogbuIhe nwere ike imeNgwọta
"Lo" ma ọ bụ "Hi" gosipụtaraTemperature is outside the measurable range (below 89.6℉ or above 109.4℉).Ensure proper measurement technique and distance. If measuring body temperature, re-measure in a stable environment.
Ọgụgụ na-ezighi ezi ma ọ bụ na-ekwekọghị ekwekọIncorrect measurement distance, dirty sensor, or environmental factors.Maintain correct distance (1-2.5 inches). Clean the sensor lens. Ensure stable room temperature. Avoid measuring immediately after physical activity or bathing.
Thermometer does not power onBatrị nwụrụ anwụ ma ọ bụ arụnyere na ezighi ezi.Lelee polarity nke batrị. Jiri batrị AAA ọhụrụ dochie ya.
Red backlight always onIndicates a temperature above the fever threshold.This is a feature, not a malfunction. If concerned, consult a healthcare professional.

6. Nkọwapụta

NjirimaraNkọwa
Oke okpomoku egosiri89.6℉ ruo 109.4℉ (32℃ ruo 43℃)
Ngosipụta mkpebi0.1 ℉/0.1 ℃
Ngalaba okpomọkụ℉ (Default) or ℃
Ike ebe nchekwa30 nha
Akụkụ155.46 (L) x 40.14 (W) x 39.45 (H) mm
Ibu61.8g (na-enweghị batrị)
Isi Iyi Ike2 x 1.5V AAA batrị alkaline
Njirimara Pụrụ IcheLarge Display, Low Battery Indicator, Ultra Clear Screen, Fast Reading System, High Accuracy
Ihe onwunwePlastic
AgbaỌcha
Onye nrụpụtaỤgwọ nke ụlọ ọrụ Taidoc Technology Corporation
Table of specifications for the FORA IR42 thermometer

Figure 7: Detailed specifications of the FORA IR42 thermometer.

7. Akwụkwọ ikike na nkwado

FORA products are manufactured to the highest quality standards. For warranty information, technical support, or any inquiries regarding your FORA IR42 thermometer, please refer to the warranty card included in your product packaging or visit the official FORA website. You may also contact customer support directly through the details provided on the packaging or websaịtị.

Vidiyo nke 2: Mwepuview of the FORA IR42 Non-Contact Forehead Thermometer.

Akwụkwọ ndị emetụtara - IR42

Tupuview Akwụkwọ ntuziaka onye ọrụ FORA Health Care System
Akwụkwọ ntuziaka onye ọrụ maka FORA Health Care System Software nke ForaCare Europe GmbH. Na-ekpuchi echichi, njikọ mita (USB/Bluetooth), njikwa data, mkpesa, na nchọpụta nsogbu maka ngwaọrụ nlekota ahụike.
Tupuview FORA MT86 Digital Thermometer: User Manual and Instructions
Comprehensive guide for the FORA MT86 digital thermometer, covering usage, safety, specifications, and warranty. Learn how to accurately measure body temperature with this medical device.
Tupuview FORA IR21 / IR20 Owner's Manual
Owner's manual for the FORA IR21 and IR20 infrared ear and forehead thermometers, providing instructions on usage, safety, troubleshooting, and specifications.
Tupuview FORA 6 Ntuziaka eriri nwale, nkọwapụta na data ziri ezi
Ntuziaka zuru oke maka FORA 6 Glucose ọbara, Hematocrit, na Hemoglobin Test Strips, na-ekpuchi iji echere, ịdọ aka ná ntị, oke, nchekwa, usoro nnwale, nsonaazụ ziri ezi na ụkpụrụ ntụaka.
Tupuview FORA 6 Ihe Nlereanya Glucose Ọbara - Ntuziaka onye ọrụ na nkọwapụta
Akwụkwọ a na-enye ozi zuru oke na FORA 6 Glucose Test Strips, gụnyere ebumnuche ebumnuche, oke, nchekwa, njikwa, usoro nnwale na nsonaazụ ziri ezi. Emebere ya maka ma ndị ọkachamara ahụike yana ndị na-ahụ maka ọrịa shuga.
Tupuview FORA Gateway Quick Start Guide: Cellular Connectivity Device Setup and Use
Concise guide to setting up and using the FORA Gateway, a cellular connectivity device for uploading FORA Bluetooth meter data to the 24/7 HealthView Telehealth System. Includes troubleshooting and FAQs.