1. Okwu mmalite
The FORA IR42 Non-Contact Forehead Thermometer is a medical-grade device designed for quick, accurate, and hygienic temperature measurement. Utilizing infrared technology, it provides readings in just one second without physical contact, making it ideal for infants, children, and adults. This manual provides comprehensive instructions for safe and effective use of your thermometer.
Figure 1: The FORA IR42 Non-Contact Forehead Thermometer.
Akụkụ ndị bụ isi:
- Nleba na-abụghị kọntaktị: Infrared sensor allows for hygienic temperature checks from a distance of 1 to 2.5 inches (3-7 cm).
- Ọgụgụ Ọsọ: Delivers accurate results in just one second.
- Arụ ọrụ-Ụdị Abụọ: Includes specific modes for both adults and children.
- Fever Indication System: Backlight changes color (green for normal, red for elevated) to visually alert users of potential fever.
- Ojiji dị iche iche: Capable of measuring body temperature as well as surface temperatures of objects or room environments.
- Nchekwa ebe nchekwa: Stores up to 30 previous measurements for easy tracking.
2. Nhazi
2.1. Unboxing na akụrụngwa
Mgbe ị meghere ngwugwu ahụ, hụ na ihe niile dị na ya dị:
- FORA IR42 Forehead Thermometer
- Batrị 2 x AAA (gụnyere)
- Akwụkwọ ntuziaka
Figure 2: Product packaging showing the thermometer and its features.
2.2. Ntinye batrị
- Locate the battery compartment cover on the back of the thermometer.
- Mia mkpuchi ala ka imeghe akụkụ ahụ.
- Tinye batrị AAA abụọ, hụ na polarity ziri ezi (+ na -) dịka egosiri n'ime ngalaba ahụ.
- Weghachite mkpuchi nke batrị batrị n'ime ebe ruo mgbe ọ pịrị na nchekwa.
Note: The thermometer requires 2 x 1.5V AAA alkaline batteries.
3. Ntuziaka ọrụ
3.1. Taking a Forehead Temperature Measurement
- Ensure the thermometer is in the correct mode (Adult or Child, see section 3.2).
- Hold the thermometer approximately 1 to 2.5 inches (3-7 cm) away from the center of the forehead.
- Pịa bọtịnụ ike (⑂) otu ugboro.
- The temperature reading will appear on the LCD display within one second.
- A green backlight indicates a normal temperature. A red backlight indicates an elevated temperature (fever).
Figure 3: Demonstrating hygienic non-contact temperature measurement.
3.2. Switching Between Adult and Child Modes
The FORA IR42 offers specific modes for adult and child temperature measurement, which may have different fever thresholds.
- With the thermometer powered on, locate the "MODE" button on the side of the device.
- Press the "MODE" button to toggle between Adult and Child modes. The display will show an icon indicating the selected mode (e.g., an adult figure or a child figure).
Figure 4: Visual representation of Adult and Child Temperature Modes.
3.3. Measuring Surface/Object Temperature
This thermometer can also measure the temperature of surfaces or objects, such as baby formula, bath water, or room temperature.
- Ensure the thermometer is in Surface mode (indicated by a thermometer icon). If not, press the "MODE" button until the surface icon appears.
- Point the thermometer at the desired surface or object from a distance of 1 to 2.5 inches (3-7 cm).
- Pịa bọtịnụ ike (⑂) otu ugboro.
- The surface temperature will be displayed.
Ọgụgụ 5: Ọpụamples of convenient object/surface temperature measurement.
3.4. Ịgbanwe n'etiti Celsius na Fahrenheit
The thermometer allows you to switch between Celsius (℃) and Fahrenheit (℉) temperature units.
- With the thermometer powered off, press and hold the "MODE" button for 2 seconds to enter the selection mode.
- Press the "MODE" button again to toggle between ℃ and ℉.
- Pịa bọtịnụ ike (⑂) to confirm your selection and exit the setting mode.
Video 1: Demonstrates how to switch temperature readings between Celsius and Fahrenheit on the FORA IR42 thermometer.
3.5. Ọrụ ebe nchekwa
The thermometer automatically stores the last 30 temperature measurements. To view agụmagụ gara aga:
- With the thermometer powered on, press the "MEMORY" button (usually located on the side, near the MODE button).
- Each press of the "MEMORY" button will cycle through the stored readings, from most recent to oldest.
Figure 6: Display showing fever indication and memory storage capability.
4. Nlekọta
4.1. Nhicha
Iji hụ na a na-agụ ihe nke ọma ma na-edebe ya ọcha, hichaa temometa ahụ mgbe niile:
- Wipe the thermometer body with a soft, dry cloth.
- For the sensor lens, gently wipe with an alcohol swab or a cotton swab moistened with alcohol. Do not use abrasive cleaners or immerse the device in water.
4.2. Nchekwa
Store the thermometer in a cool, dry place, away from direct sunlight, extreme temperatures, and humidity. Remove batteries if the device will not be used for an extended period to prevent leakage.
5. Nchọpụta nsogbu
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| "Lo" ma ọ bụ "Hi" gosipụtara | Temperature is outside the measurable range (below 89.6℉ or above 109.4℉). | Ensure proper measurement technique and distance. If measuring body temperature, re-measure in a stable environment. |
| Ọgụgụ na-ezighi ezi ma ọ bụ na-ekwekọghị ekwekọ | Incorrect measurement distance, dirty sensor, or environmental factors. | Maintain correct distance (1-2.5 inches). Clean the sensor lens. Ensure stable room temperature. Avoid measuring immediately after physical activity or bathing. |
| Thermometer does not power on | Batrị nwụrụ anwụ ma ọ bụ arụnyere na ezighi ezi. | Lelee polarity nke batrị. Jiri batrị AAA ọhụrụ dochie ya. |
| Red backlight always on | Indicates a temperature above the fever threshold. | This is a feature, not a malfunction. If concerned, consult a healthcare professional. |
6. Nkọwapụta
| Njirimara | Nkọwa |
|---|---|
| Oke okpomoku egosiri | 89.6℉ ruo 109.4℉ (32℃ ruo 43℃) |
| Ngosipụta mkpebi | 0.1 ℉/0.1 ℃ |
| Ngalaba okpomọkụ | ℉ (Default) or ℃ |
| Ike ebe nchekwa | 30 nha |
| Akụkụ | 155.46 (L) x 40.14 (W) x 39.45 (H) mm |
| Ibu | 61.8g (na-enweghị batrị) |
| Isi Iyi Ike | 2 x 1.5V AAA batrị alkaline |
| Njirimara Pụrụ Iche | Large Display, Low Battery Indicator, Ultra Clear Screen, Fast Reading System, High Accuracy |
| Ihe onwunwe | Plastic |
| Agba | Ọcha |
| Onye nrụpụta | Ụgwọ nke ụlọ ọrụ Taidoc Technology Corporation |
Figure 7: Detailed specifications of the FORA IR42 thermometer.
7. Akwụkwọ ikike na nkwado
FORA products are manufactured to the highest quality standards. For warranty information, technical support, or any inquiries regarding your FORA IR42 thermometer, please refer to the warranty card included in your product packaging or visit the official FORA website. You may also contact customer support directly through the details provided on the packaging or websaịtị.
Vidiyo nke 2: Mwepuview of the FORA IR42 Non-Contact Forehead Thermometer.