OSITO Foot Circulation Plus EMS TENS Device User Manual

Model: ABCD

1. Okwu mmalite

The OSITO Foot Circulation Plus is a medical device designed to provide electrical muscle stimulation (EMS) and transcutaneous electrical nerve stimulation (TENS) for the feet and body. This device aims to relax stiff muscles and nerves, and reduce swelling in the feet and legs. It is an FDA-cleared Class II medical device, identified by certificate code K133929.

2. Ozi nchekwa na ịdọ aka ná ntị

Please read all safety information carefully before using the device. Failure to follow these instructions may result in injury or damage to the device.

3. Ngwa ngwaahịa

The OSITO Foot Circulation Plus device includes the main unit, a remote controller, an AC power adapter, and four TENS electrode pads with connecting wires.

OSITO Foot Circulation Plus device and accessories

Image: The OSITO Foot Circulation Plus main unit, remote control, power adapter, and TENS pads.

4. Nhazi ntuziaka

  1. Njikọ ike: Ensure the device is placed on a stable, flat surface. Connect the AC power adapter to the device and then plug it into a power outlet. The LED light and screen will flash once, indicating proper power connection.
  2. Batrị njikwa anya: Insert two AAA batteries into the remote control (batteries are included).
  3. TENS Pad Connection (Optional): If using the body stimulation feature, connect the TENS pads to the device using the provided wires. Ensure the pads are securely attached to the desired body areas.

5. Ntuziaka ọrụ

5.1 Gbanyụọ/ gbanyụọ

Press the "on/off" button on the device for 1-2 seconds, or use the remote control to turn the machine on or off.

5.2 Foot Stimulation

Place both bare feet on the foot pads of the device simultaneously. Ensure good contact between your feet and the pads. You may slightly dampen your feet for better conductivity if needed.

Feet placed on the OSITO Foot Circulation Plus device

Image: A user's feet positioned on the foot pads of the device, illustrating proper usage for foot stimulation.

5.3 Body Stimulation (TENS Unit)

Attach the TENS electrode pads to the desired areas of your body, such as the calf, ankle, legs, hips, lower back, shoulder, or waist. Connect the pads to the device. The foot and body stimulation systems can be used together or separately.

Diagram showing TENS pad placement on various body parts

Image: A visual guide demonstrating appropriate placement of TENS pads on different body areas for targeted relief.

5.4 nhazi nhazi

The device features a large colorful LCD display to show current settings. Use the control buttons on the device or the infrared remote controller to adjust parameters.

Close-up of the OSITO Foot Circulation Plus display and controls

Foto: Zuru ezu view of the device's LCD screen and control buttons, highlighting the various settings and indicators.

Person using the OSITO Foot Circulation Plus with remote control

Image: A person comfortably using the OSITO Foot Circulation Plus while operating it with the remote control.

6. Nlekọta

To ensure the longevity and proper functioning of your OSITO Foot Circulation Plus device, follow these maintenance guidelines:

7. Nchọpụta nsogbu

If you encounter any issues with your device, refer to the following common troubleshooting steps:

8. Nkọwapụta

NjirimaraNkọwapụta
Nọmba nlereanyaABCD
Akụkụ ngwaahịa15.75 x 15.75 x 5.12 sentimita asatọ
Ibu Ibu6.25 pound
Isi Iyi IkeIgwe ọkụ eletrik
Batrị (ime ime)2 batrị AAA (gụnyere)
Ọkwa ike99 (Foot & Body)
Ụdị ịhịa aka n'ahụ25 Waveforms
Ngụ ogeAutomatic 25-minute
Ihe onwunweỌla

9. Akwụkwọ ikike na nkwado

For warranty information, technical support, or any questions regarding your OSITO Foot Circulation Plus device, please contact OSITO customer service. Refer to the product packaging or the official OSITO websaịtị maka nkọwa kọntaktị kachasị ugbu a.

Akwụkwọ ndị emetụtara - ABCD

Tupuview Akwụkwọ ntuziaka onye ọrụ nkwalite ọbara okirikiri OSITO: TENS & Teknụzụ EMS
Akwụkwọ ntuziaka onye ọrụ zuru oke maka OSITO Circulation Blood Booster, na-akọwapụta teknụzụ TENS na EMS ya, atụmatụ, ọrụ, mmezi, na nchọpụta nsogbu maka enyemaka mgbu dị irè na mkpali akwara.
Tupuview Nlekọta nke Ketoacidosis na-arịa ọrịa shuga n'ime ndị okenye: ntuziaka ụlọ ọgwụ JBDS
Ntuziaka a sitere na Joint British Diabetes Societies (JBDS) na-enye ndụmọdụ zuru oke, ihe akaebe na-egosi maka njikwa nke Ketoacidosis Diabetic (DKA) na ndị okenye, emelitere na March 2023. Ọ na-ekpuchi nchọpụta, ụzọ ọgwụgwọ, na usoro nlekọta maka ndị ọkachamara ahụike.
Tupuview Nduzi njedebe nke ndụ maka nlekọta ọrịa shuga: ntuziaka zuru oke maka ndị ọkachamara nlekọta ahụike
Ntuziaka a na-enye ndị ọkachamara ahụike ndụmọdụ na atụmatụ dị mkpa maka ijikwa nlekọta ọrịa shuga maka ndị mmadụ n'otu n'otu na-eru nso na njedebe nke ndụ, na-ekpuchi isiokwu sitere na njikwa ọgwụ ruo na nlekọta ahụike.
Tupuview Ntuziaka omume kacha mma: Iji teknụzụ ọrịa shuga n'ime ime
Ntuziaka a na-enye nkwenye ndị ọkachamara UK na usoro kachasị mma maka ijikwa ọrịa shuga n'ime afọ ime site na iji ọgwụgwọ mgbapụta insulin (CSII) na sensọ glucose (RT-CGM, Flash Glucose Monitoring). Ọ na-akọwapụta ihe akaebe, egosi, ntọlite, atumatu njikwa, na nleba anya ọrụ iji melite nsonaazụ nne na nwa ọhụrụ.
Tupuview ERP AWM1: Module ikanam agba agba nwere DMX512-A-RDM
Chọpụta ERP AWM1, ihe ntinye AC na-arụ ọrụ dị elu tunable LED modul. Ọ na-enye oke CCT sara mbara (1800K-6500K), njikwa RGBW nke ọ bụla, yana ndakọrịta DMX512-A-RDM maka imepụta ọkụ ọkaibe yana ngbanwe agba.